NOTE:
These
recommendations
will
provide
optimal
protection
against
EMI
and
RFI.
The
actual
cable
type,
wire
gauge,
shield
type
and
filtering
devices
used
are
dependent
on
the
customer’s
application
and
system.
Driver
Supply
Cable
AWG
Table
1
Amp
(Peak)
Length
(Feet)
10
25
50*
75*
100*
Minimum
AWG
20
20
18
18
16
2
Amps
(Peak)
Length
(Feet)
10
25
50*
75*
100*
Minimum
AWG
20
18
16
14
14
3
Amps
(Peak)
Length
(Feet)
10
25
50*
75*
100*
Minimum
AWG
18
16
14
12
12
*
Use
the
alternative
methods
illustrated
in
Examples
B
and
C
when
the
cable
length
is
≥
50
feet.
Also,
use
the
same
current
rating
when
the
alternate
AC
power
is
used
Driver
Supply
Cable
Wire
Size
NOTE:
Always
use
Shielded/Twisted
Pairs
for
the
Driver
DC
Supply
Cable,
the
AC
Supply
Cable
and
the
Driver
to
Motor
Cable.