Velocity Move<value>
Command Only +/- 250 to 15,000, or 0
The sign of the value determines the direction (positive for forward, and negative for
backward) in which the velocity move is made. The value sets the step rate in steps
per second at the current step resolution. Velocity cannot exceed Velocity Limit
The move begins at the set ‘Minimum Velocity’ (MV), with the speed ramping to the
command velocity at the rate set by ‘Acceleration’ (AC).
Changes to new velocity values from new VM commands, will also occur at the rate
set by ‘Acceleration’ (AC).
Command Example
#AVM1000<cr><lf> Starts a velocity move of 1000 steps per second.