Tools required for installation: 

 

3 pair communication cable - Take a rough estimate of the cable length from the Water Level 
Controller (WLC) location to the Over Head Tank (OHT) 

 

Multi-strand 1.5 Sq.mm copper power cable – Cable length as per your requirement for power 
connection. 

 

Insulation tape, Line tester, Wire stripper, Simple hammer, Drill gun, Wooden Gattas, 2 Screws 

for mounting the WLC on the wall.

 

 

Installation steps for Switch/MCB model 

Sensor Connection 

Step 1:

 Immerse the sensors as per the color coding given in the below picture. 

Step 2

: Dry Run Connection (If dry run connection is not possible for your tank, you must 

join the DR and CN wires of the controller and use it as common wire).

 

 

Power Connection

 

Caution: Switch off the main power while doing the Power Connection steps. 

Starter type connection: 

Step  1: 

Connect  Phase  and  neutral  (230V)  to  red  and  black  (paired)  wire  of  the  controller 

respectively as shown in the 

Picture2

Step 2: 

Remove the wire which connects the start and stop button terminals.

 

Connect one wire 

of blue pair and one wire of black pair to the start button where the wire was removed as shown in the 

Picture 4

Step 3:

 Connect the other wire of blue pair in parallel to the same side of the start button. 

Step 4:

 Connect the other wire of the black pair to the stop button where the wire was removed 

as shown in the 

Picture 2. 

Switch type connection: 

Step 1:

 Connect Phase and neutral (AC 230V) to red and black (paired) wire of the controller 

respectively as shown in the 

Picture3

Step 2: 

Connect Blue pair cable to the switch or MCB in parallel as shown in the 

Picture3

In  case  of  doubts  please  call  044  -  43180017  and  for  What’s  App  9940594413  from 

Monday to Saturday 10 am to 6 pm. 

 

Working video link: 

https://www.youtube.com/watch?v=UIw3ItC9DSw&feature=emb_logo

 

Starter connection:  

 

 

Picture2

 