Since there are two independent MADI ports, the total supported number of channels can
be multiplied by two. Since there are eight independent AVB streams, the total supported
number of channels can be multiplied by eight. The analog channel count remains identical
at all sample rates.
11.3.3. Selecting a Sample Rate
To configure the device sample rate on the device:
1. Enter the
CLOCK
section. The cursor highlights the currently selected clock.
2. Rotate the encoder to highlight the current sample rate.
3. Push the encoder. Two blue arrows will appear to indicate that the encoder can now be used to
change the current setting.
4. Rotate the encoder until the preferred sample rate is shown.
5. Push the encoder again to activate the setting.
11.3.4. Effects of Sample Rate Changes on Existing Routing
The M-1610 Pro saves one routing table per preset, regardless of sample rate. A change of sample rate
or MADI frame mode can reduce the number of input and output channels available for routing. This
does not alter the routing table. Any existing routing is hidden until another change of sample rate re-
enables the channels.
Example:
A routing is created at 96 kHz with 32 channels, sending the MADI coaxial Input 1-32 to optical MADI
Output 1-32. If the sample rate is now changed to 176.4 kHz and the 56 Ch frame is activated, only the
first 14 channels of MADI coaxial input are routed to the optical output. Switching the sample rate to 44.1
or 48 kHz will reveal the previous routing for 32 channels.