28
User's Guide HDSPe MADI
© RME
Clock Mode
The unit can be configured to use
its internal clock source (Master),
or the clock source pre-defined via
Pref. Sync Ref
(AutoSync).
Pref. Sync Ref.
Used to pre-select the desired
clock source. If the selected
source isn't available, the unit will
change to the next available one.
The current clock source and
sample rate is displayed in the
AutoSync Reference
display.
The automatic clock selection
checks and changes between the
clock sources Word Clock, MADI,
TCO and Sync In.
Input Status
Displays the state of the current
input signal:
•
Channel format (64 or 56 channels)
•
Frame format (48K or 96K)
•
Sample rate (measured)
•
Active input (optical or coaxial)
System Clock
Shows the current clock state and sample rate of the HDSP system. The system is either Mas-
ter (using its own clock) or Slave (see AutoSync Ref).
SyncCheck
SyncCheck
indicates whether there is a valid signal (Lock) for the inputs Word Clock, MADI,
TCO and Sync In, or if there is a valid
and
synchronous signal (Sync). The
AutoSync Reference
display shows the input and frequency of the current sync source.
Содержание HDSPe MADI
Страница 5: ...User s Guide HDSPe MADI RME 5 User s Guide HDSPe MADI General ...
Страница 11: ...User s Guide HDSPe MADI RME 11 User s Guide HDSPe MADI Driver Installation and Operation Windows ...
Страница 25: ...User s Guide HDSPe MADI RME 25 User s Guide HDSPe MADI Driver Installation and Operation Mac OS X ...
Страница 33: ...User s Guide HDSPe MADI RME 33 User s Guide HDSPe MADI Connections and TotalMix ...
Страница 40: ...40 User s Guide HDSPe MADI RME ...
Страница 62: ...62 User s Guide HDSPe MADI RME ...
Страница 63: ...User s Guide HDSPe MADI RME 63 User s Guide HDSPe MADI Technical Reference ...