background image

 

 

User’s Guide HDSP System Digiface 

© RME

 

23

 

 

14.8 Level Meter  

 
Having set a new standard with the level meters of DIGICheck, Hammerfall DSP goes even 
further: The calculation of the Peak, RMS and Over is realized in hardware, in order to be 
capable of using them independent of the software in use, and to significantly reduce the CPU 
load. 
 
The level meters integrated in TotalMix - considering their size - cannot be compared with the 

HDSP Meter Bridge

 (available later). Nevertheless they already include many useful functions. 

 
Peak and RMS is displayed for every channel. 'Level Meter Setup' (Menu Options) or direct 
keyboard entry (

hotkeys

) makes various options available: 

 

• 

Display range 40 or 60 dB (

hotkey 4 or 6

• 

Release time of the Peak display (Fast/Medium/Slow) 

• 

Numerical display selectable either Peak or RMS (

Hotkey E or R

• 

Number of consecutive samples for Overload display (1 to 15) 

• 

RMS display absolute or relative to 0 dBFS (

Hotkey 3 or 0

 
The latter is a point often overlooked, but nonetheless 
important. RMS shows 3 dB less for sine signals. This 
is mathematically correct, but not very reasonable for 
a level meter. Therefore, we had corrected 
DIGICheck's RMS display by 3 dB, a full scale sine 
signal shows both 0 dBFS Peak and RMS. This setting 
also yields directly readable signal-to-noise values, 
while other applications (like WaveLab) will show a 
value 3 dB better than actual (because the reference 
is not 0 dB, but -3 dB). 
 
The value displayed in the text field is independent of 
the setting 40/60 dB, it represents the full 24 bit range 
of the RMS measurement, thus making possible a 
SNR measurement 'RMS unweighted', which you 
would otherwise need extremely expensive 
measurement devices for. An ADI-8 DS connected to 
the Digiface will therefore show around -113 dB on all 
8 channels. 
 
This level display will constantly bring the reduced 
dynamic range of your equipment, maybe of the whole studio, in front of your eyes. Nice to 
have everything 24 bit - but still noise and hum everywhere in the range around -90 dB or 
worse... sorry, but this is hard reality. The up-side about it is that TotalMix allows for constantly 
monitoring the signal quality without effort. Thus it can be a valuable tool for sound optimization 
and error removal in the studio. 
 

Measuring SNR (Signal to Noise) requires to press R (for RMS) and 0 (for referring to 0 
dBFS, a full scale signal). The text display will then show the same value as an expensive 
measurement system, when measuring ‘RMS unweighted’.

 

 

Note: There is no RMS calculation for the third row, the physical outputs. Therefore these green 
bars show the peak value. 

 

 

Содержание DIGIFACE

Страница 1: ...Hammerfall DSP System Digiface PCI Busmaster Digital I O System PCI and CardBus Interface 2 24 Channels Stereo ADAT Interface 24 Bit 96 kHz Analog Stereo Monitor ADAT Sync In TotalMix 24 Bit 96 kHz S...

Страница 2: ...ables and Termination 14 10 3 General Operation 15 11 Using more than one Hammerfall DSP 15 12 Special Characteristics of the SPDIF Output 15 13 Operation under ASIO 2 0 13 1 General 16 13 2 Performan...

Страница 3: ...functions directly in hardware and not in the driver i e the CPU 2 Package Contents Please check that your Hammerfall DSP Systems package contains each of the following PCI Interface PCI card HDSP Qu...

Страница 4: ...Line headphone output separate output for independent submix DIGICheck DSP Level meter in hardware peak and RMS calculation TotalMix 1456 channel mixer with 40 bit internal resolution 5 Technical Spe...

Страница 5: ...he computer s housing Further information on how to do this can be obtained from your computer s instruction manual 3 Important Before removing the card from its protective bag discharge any static in...

Страница 6: ...iles The driver installation is done manually in 5 steps 1 Drag the file Hammerfall DSP Driver from into System folder into the System folder It will be installed automatically into the Extension fold...

Страница 7: ...mixer of the Digiface TotalMix requires Carbon Library 1 1 which is part of the operating system since MacOS 9 1 After installation of Carbon Library 1 1 TotalMix can even be run on older systems dow...

Страница 8: ...iface has the first MIDI input and output the power supply connector AUX only needed with CardBus operation and all digital inputs and outputs ADAT I O TOSLINK 1 to 3 The ADAT1 I O can also be used fo...

Страница 9: ...rrent configuration the board itself and all connected external equipment If no sample frequency is recognized it will read No Lock With this configuring any suitable audio application for digital rec...

Страница 10: ...ng the dialog is not required However settings should not be changed during playback or record if it can be avoided as this can cause unwanted noises Also please note that even in Stop mode several pr...

Страница 11: ...he settings Professional Emphasis and Non Audio please refer to chapter 12 Clock Mode The card can be configured to use its internal clock Master or the clock source pre defined via Pref Sync Ref Auto...

Страница 12: ...ster If the HDSP s clock mode is set to Master all other devices must be set to Slave All the ADAT optical inputs in the Hammerfall DSP as well as the SPDIF input will work simultaneously Because ther...

Страница 13: ...requency of the mixing desk but not identical Remedy To drive the ADAT recorder from its digital input set it to slave mode DIG and connect the input to the HDSP s ADAT3 output The Hammerfall DSP is a...

Страница 14: ...commend using off the shelf BNC cables to connect all devices as this type of cable is used for most computer networks You will find all the necessary components T adapters terminators cables in most...

Страница 15: ...d header and creates a totally new one for the output signal Note that in record or monitor modes set emphasis bits will disappear Recordings originally done with emphasis should always be played back...

Страница 16: ...the device ASIO Hammerfall DSP 96 kHz has to be chosen When the sample frequency is set to 88 2 or 96 kHz this driver operates all the ADAT optical inputs and outputs in Sample Split mode so the numb...

Страница 17: ...Cubase s transport panel will open the Synchronization dialog Select ASIO 2 0 as the timecode base under Sync Source confirm the dialog with OK then activate Sync mode by single clicking on the Sync...

Страница 18: ...he Surface The visible design of the mixer is mainly determined by the architecture of the HDSP system Upper row hardware inputs The level shown is that of the input signal i e Fader independent Per f...

Страница 19: ...two channels It is therefore helpful to be able to make the routing settings for two channels at once Press the Ctrl key and click into the routing window of Out 3 with the key pressed The routing lis...

Страница 20: ...lo the Mute buttons for Out 1 to Out 4 light up as before And if you chose Solo for a channel of this Mute group mute will be deactivated but immediately activated again if Solo is released 14 5 Hotke...

Страница 21: ...ous view The mixer can also be made smaller horizontally and scrolled TotalMix can be made substantially smaller and space saving on the desktop screen if you have to have to monitor or set only a few...

Страница 22: ...All inputs maximum attenuation m a All playback channels 0 dB routet to the same output All output channels 0 dB phones 6 dB Submix of all inputs and outputs to the analog output Phones with input fad...

Страница 23: ...nal shows both 0 dBFS Peak and RMS This setting also yields directly readable signal to noise values while other applications like WaveLab will show a value 3 dB better than actual because the referen...

Страница 24: ...switches off power the red Host LED begins to blink The card can now be pulled out of the PCMCIA slot The Hammerfall DSP System was tested thoroughly on several notebooks by RME We did not find any co...

Страница 25: ...nnels don t seem to work S PDIF output has been switched to ADAT1 This means that the first ADAT output device and therefore the first 8 channels in the ASIO application are no longer available All ch...

Страница 26: ...vice The following symptoms are typical for PCI related problems When booting the control panels are displayed too big or spread across the whole screen Software or OS crash as soon as the card is use...

Страница 27: ...wlessly even with a cable length of up to 50ft 15 m 36081 RME Firewire cable for CardBus 15 6M 5 m 16 4 ft Special cable 15 pin close Lan coded to 6 pin male for RME CardBus card 36003 Optical cable T...

Страница 28: ...ivers Configuring Logic Samplitude and Cubase for the DIGI32 96 series Configuring Cakewalk and SAWPlus32 for the DIGI32 96 series Step by step instructions DIGICheck Analysis tests and measurements w...

Страница 29: ...rectory into your browser Trademarks All trademarks registered or otherwise are the property of their respective owners RME DIGI96 SyncAlign SyncCheck ZLM and Hammerfall are registered trademarks of R...

Страница 30: ...User s Guide HDSP System Digiface RME 30 22 Diagrams 22 1 Block Diagram Digiface...

Страница 31: ...ths in ASIO double speed mode 88 2 96 kHz The devices available under ASIO have been implemented according to the hardware Signal routing is identical for record and playback Device The device name in...

Страница 32: ...w inside the TotalMix mixer of the Digiface It shall clarify the following function The input signal of the hardware ADAT SPDIF In is always directly fed through to the recording software At the same...

Страница 33: ...ies and if not installed and used according to the instructions in the User s Guide may cause interference harmful to the operation of other electronic devices Compliance with FCC regulations does not...

Отзывы: