PLACEMENT
The device must be instalated in well ventilated room what is necessary for regulation of the function of the
device (technician must go by valid standard (EN....). If the device is situated close to the wall or if it is in
contact with the furniture walls, these walls must resist the temperatures ranging to 90°C. Instalation, setting,
putting into operation must be done by qualifi ed person who is competent for this and according to the valid
standards.
Wrap up the device and check whether it was not damaged during transport. Settle the device on horizontal
surface (max imbalance 2°).Settle the device under the fumehood to eliminate water steam and bad smell.
The device can be instalated separately or in a set with devices of our production. Min. distance 10 cm
from other subjects must be kept.It is also necessary to prevent our product from contact with combustible
materials. In this case you must make corresponding changes to secure heat izolation of combustible parts.
Safety measures from the standpoint of the fi re protection according to EN 061008čl. 21:
PACKING AND DEVICE CHECK
The device leaves our stocks properly packed with appropriate symbols and labels. There are also appropriate
instructions for use. In case the packing shows bad handling or damage, it must be reclaimed at transporter
immediately by writing and signing of a damage protocol.
Important notice:
• only for proff esional use
• this instructing guide must be read properly and carefully because it contains important information about
safety elements, installation, use
• these recommendations refer to this product
• this product corresponds with valid standards
• this guide must be properly deposited for future use
• keep the children away from manipulation with the product
• when selling or moving the product to another place it is necessary top make yourself sure that the staff
or the professional service has got acquainted with control and installation instructions from enclosed guide
• only authorised person can operate the product
• it can not be switched on without supervision
• we recommend to have the product checked by professional service min. once a year
• only original spare parts can be used for repairs
• the product can not be cleaned by the water jet or pressure shower
• by damage or break down disconnect all the feeders (water, gas, electricity) and call professional service
• producer refuses any responsibility in case of damages caused by wrong installation, by disobserving of
above mentioned recommendations or by other use etc.
Data
Type of gas
Burner 8,5 kW
G30
28-30 mbar
G30
37 mbar
G30
50 mbar
G20
20 mbar
G25
25 mbar
G25
20 mbar
G20
25 mbar
Main burner diameter
1/100mm
145
140
130
215
225
245
205
Air kontrol _settings (mm)
open
open
open
3,5
3,5
3,5
3,5
Gas Consumption
0,670 kg/h
0,670 kg/h 0,670 kg/h 0,899 m
3
/h 1,046 m
3
/h 1,046 m
3
/h 0,899 m
3
/h
Burner 4 kW
Main burner diameter
1/100mm
95
90
85
150
155
165
140
Air kontrol _settings (mm)
open
open
open
closed
closed
closed
closed
Gas Consumption
0,355 kg/h
0,355 kg/h 0,355 kg/h 0,476 m
3
/h 0,554 m
3
/h 0,554 m
3
/h 0,476 m
3
/h
Burner 6 KW OVEN
Main burner diameter
1/100mm
125
115
110
180
195
205
175
Air kontrol _settings (mm)
13
13
13
13
13
13
13
Gas Consumption
0,473 kg/h
0,473 kg/h 0,473 kg/h 0,635 m
3
/h 0,738 m
3
/h 0,738 m
3
/h 0,635 m
3
/h
Pilot burner
diameter 1/100mm
24
24
24
adjusting
adjusting
adjusting
adjusting
Pilot burner OVEN
diameter 1/100mm
13
13
13
36
36
36
36
Data
Type of gas
Burner 8,5 kW
G25.1
25 mbar
G2.350
13 mbar
G27
20 mbar
G31
30-37 mbar
G31
37 mbar
G31
50 mbar
Main burner diameter
1/100mm
240
315
250
145
140
130
Air kontrol _settings (mm)
3,5
open
3,5
open
open
open
Gas Consumption
1,044 m
3
/h
1,249 m
3
/h 1,097 m
3
/h
0,660 kg/h
0,660 kg/h 0,660 kg/h
Burner 4 kW
Main burner diameter
1/100mm
160
205
170
95
90
85
Air kontrol _settings (mm)
closed
closed
closed
open
open
open
Gas Consumption
0,553 m
3
/h
0,661 m
3
/h 0,581 m
3
/h
0,350 kg/h
0,350 kg/h 0,350 kg/h
Burner 6 KW OVEN
Main burner diameter
1/100mm
195
260
205
125
115
110
Air kontrol _settings (mm)
13
13
13
13
13
13
Gas Consumption
0,737 m
3
/h 0,882 m
3
/h 0,774 m
3
/h
0,466 kg/h
0,466 kg/h 0,466 kg/h
Pilot burner
diameter 1/100mm
adjusting
adjusting
adjusting
24
24
24
Pilot burner
diameter 1/100mm
36
36
36
13
13
13
Содержание SPST-7120 G
Страница 11: ...11...
Страница 23: ...23...
Страница 35: ...35...
Страница 40: ...40 DIMENSION PLANS MASSSKIZZEN DIMENSIONS SPST 780 21 GE SPST 780 11 G...
Страница 41: ...41 SPST 780 21 G SPST 7120 21 A B G...
Страница 42: ...42 SPST 7120 21 A B GE SPST 7120 31 GE...
Страница 43: ...43 SPST 7120 31 G...
Страница 45: ...45 connection modules Anschlussmodule les modules de connexion...
Страница 46: ...46...