RKI 61-0140RK-05 Скачать руководство пользователя страница 3

 

61-1000RK-05/61-0140RK-05 Combustible Gas Detector

Product Warranty

RKI Instruments, Inc. warranties gas alarm equipment sold by us to be free from defects in 
materials, workmanship, and performance for a period of one year from date of shipment 
from RKI Instruments, Inc. Any parts found defective within that period will be repaired 
or replaced, at our option, free of charge. This warranty does not apply to those items 
which by their nature are subject to deterioration or consumption in normal service, and 
which must be cleaned, repaired, or replaced on a routine basis. Examples of such items 
are:

Warranty is voided by abuse including mechanical damage, alteration, rough handling, or 
repair procedures not in accordance with the operator’s manual. This warranty indicates 
the full extent of our liability, and we are not responsible for removal or replacement costs, 
local repair costs, transportation costs, or contingent expenses incurred without our prior 
approval.

THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER 
WARRANTIES AND REPRESENTATIONS, EXPRESSED OR IMPLIED, 
AND ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF 
RKI INSTRUMENTS, INC. INCLUDING BUT NOT LIMITED TO, THE 
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A 
PARTICULAR PURPOSE. IN NO EVENT SHALL RKI INSTRUMENTS, 
INC. BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL 
LOSS OR DAMAGE OF ANY KIND CONNECTED WITH THE USE OF 
ITS PRODUCTS OR FAILURE OF ITS PRODUCTS TO FUNCTION OR 
OPERATE PROPERLY.

This warranty covers instruments and parts sold to users by authorized distributors, 
dealers, and representatives as appointed by RKI Instruments, Inc.

We do not assume indemnification for any accident or damage caused by the operation of 
this gas monitor, and our warranty is limited to the replacement of parts or our complete 
goods.

a) Absorbent cartridges

d) Batteries

b) Pump diaphragms and valves

e) Filter elements

c) Fuses

Содержание 61-0140RK-05

Страница 1: ...www rkiinstruments com 61 1000RK 05 61 0140RK 05 Combustible Gas Detector Operator s Manual Part Number 71 0087RK Revision F Released 10 26 18...

Страница 2: ...h Periodic calibration and maintenance of the detector is essential for proper operation and correct readings Please calibrate and maintain this detector regularly Frequency of calibration depends upo...

Страница 3: ...or replacement costs local repair costs transportation costs or contingent expenses incurred without our prior approval THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES AND REPRESENT...

Страница 4: ...g the Combustible Gas Detector 7 Wiring the Combustible Gas Detector 8 Startup 10 Introducing Incoming Power 10 Setting the Zero Signal 10 Maintenance 11 Preventive Maintenance 11 Troubleshooting 11 R...

Страница 5: ...references to the junction box and junction box terminal strip Specifications WARNING Do not use this product in a manner not specified in this instruction manual Table 1 lists specifications for the...

Страница 6: ...ubs are normally 3 4 NPT so a 3 4 x 1 2 NPT reducer may be necessary to install the combustible gas detector A flame arrestor guard is located at the bottom of the detector and is permanently bonded t...

Страница 7: ...controller conduit hub Mounting the Combustible Gas Detector 1 Select a mounting site that is representative of the monitoring environment Consider the following when you select the mounting site Sele...

Страница 8: ...ed NEMA 4X and classified explosion proof for Class I Groups B C and D 6 Connect the wires to the terminal block in the junction box WARNING To maintain the explosion proof classification of the LEL d...

Страница 9: ...stible Gas Detector 9 Figure 3 Wiring the Combustible Gas Detector to a Controller Green White Red Controller LEL Detector Terminals J Box Terminal Strip Black Detector W ires Red Green White Combusti...

Страница 10: ...eading Setting the Zero Reading WARNING Do not remove the junction box cover while the circuits are energized unless the area is determined to be non hazardous Keep the junction box cover tightly clos...

Страница 11: ...on Fail Condition Controller indicates a fail condition The detector wiring is disconnected or misconnected The detector zero signal is low enough to cause a fail condition The detector is malfunction...

Страница 12: ...for environmental conditions apply thread sealant or Teflon tape to the hub and or detector threads to seal them 7 If the detector is installed directly on a controller connect the detector leads to t...

Страница 13: ...Calibration This section describes how to calibrate the combustible gas detector It includes procedures to prepare for calibration set the zero reading set the response reading and return to normal op...

Страница 14: ...ector to gas turn the regulator s on off knob counterclockwise to open it 3 Allow the gas to flow for one minute before continuing with the directions 4 After setting the response reading turn the reg...

Страница 15: ...in air 34 liter steel 81 0004RK 03 Calibration cylinder 50 LEL propane in air 103 liter 81 0007RK 01 Calibration cylinder 15 LEL hexane in air 34 liter steel 81 0012RK 01 Calibration cylinder 50 LEL m...

Отзывы: