65-2507RK Oxygen Transmitter • 4
Overview
This instruction manual describes the oxygen transmitter. This manual also describes how
to install, start up, configure, maintain, and calibrate the transmitter when using it with a
gas monitoring controller. A parts list at the end of this manual lists replacement parts and
accessories for the oxygen transmitter. See the operator’s manual for the controller for
information specific to the controller.
Specifications
Table 1 lists specifications for the oxygen transmitter.
Table 1:
Specifications
Description
Specification
Target Gas
Oxygen (O
2
)
Area Classification
Explosionproof for Class I, Groups B, C, and D
Sampling Method
Diffusion
Signal Output
4 - 20 mA
Detection Range
0 to 25.0% VOL (by volume)
Response Time
90% in 30 seconds