Table 5 lists replacement parts and accessories for the combustible gas transmitter.

Table 5:Parts List

Part Number

Description

06-1248RK

Sample tubing (3/16 in. x 5/16 in.; specify length when ordering)

18-0001RK

Reducer, 3/4 NPT x 1/2 NPT

18-0400RK-01

Junction box with spacers

57-1053RK

Amplifier with gasket (specify target gas and that the 61-0140RK-05 detector is 

being used when ordering)

61-0140RK-05

Combustible gas detector, CSA type

71-0547

65-2405RK-05-04 Combustible Gas Transmitter Operator’s Manual 

(this document)

81-0002RK-01

Steel calibration cylinder, 50% LEL hydrogen in air, 34 liter steel

81-0007RK-01

Steel calibration cylinder, 15% LEL hexane in air, 34 liter steel

81-0012RK-01

Steel calibration cylinder, 50% LEL methane in air, 34 liter steel

81-0076RK-01

Steel calibration cylinder, zero emission air, 34 liter steel

81-1050RK

Regulator, 0.5 LPM, with pressure gauge and flow control knob, for 17 liter and 34 

liter steel calibration cylinders (cylinders with external threads)

81-1116RK

Calibration cup/splash guard

81-F001RK-LV

Calibration kit, includes regulator, sample tubing, calibration cup, and 34 liter

15% LEL hexane in air steel calibration cylinder

81-F002RK-LV

Calibration kit, includes regulator, sample tubing, calibration cup, and 34 liter

50% LEL methane in air steel calibration cylinder

81-F004RK-LV

Calibration kit, includes regulator, sample tubing, calibration cup, and 34 liter

50% LEL hydrogen in air steel calibration cylinder

Содержание 65-2405RK-05-04

Страница 1: ...RKI Instruments Inc www rkiinstruments com 65 2405RK 05 04 Combustible Gas Transmitter Operator s Manual Part Number 71 0547 Revision P1 Released 2 1 21...

Страница 2: ...eriodic calibration and maintenance of the detector is essential for proper operation and correct readings Please calibrate and maintain this detector regularly Frequency of calibration depends upon t...

Страница 3: ...replacement costs local repair costs transportation costs or contingent expenses incurred without our prior approval THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES AND REPRESENTATI...

Страница 4: ...Detector to the Amplifier 12 Wiring the Amplifier to a Controller 12 Startup 13 Introducing Incoming Power 13 Setting the Zero Signal 14 Maintenance 14 Preventive Maintenance 14 Troubleshooting 15 Re...

Страница 5: ...tation for installation instructions WARNING When using the 65 2405RK 05 04 you must follow the instructions and warnings in this manual to assure proper and safe operation of the 65 2405RK 05 04 and...

Страница 6: ...end allowing ambient air to diffuse into the detector The flame arrestor also contains any sparks which may occur within the detector The 1 2 NPT mounting threads at the top of the detector allow you...

Страница 7: ...lug in style terminal strip located near the top of the amplifier Use the controller terminal strip to wire the transmitter to a controller Detector Terminal Strip The detector terminal strip is a fou...

Страница 8: ...installed remotely from the amplifier junction box The combustible gas detector is factory installed in the bottom 3 4 NPT conduit hub A terminal strip is provided for wiring connections and the detec...

Страница 9: ...g down see Figure 3 3 Install 3 16 inch I D flexible polyurethane tubing to the fitting at the bottom of the calibration cup splash guard and route it to an accessible area that is close to the amplif...

Страница 10: ...tector junction box s cover to the junction box 7 Guide the other end of the four conductor shielded cable or four wires in conduit through the bottom conduit hub of the amplifier junction box 8 To ga...

Страница 11: ...at the amplifier junction box The amplifier mounting screw is a convenient grounding location Install a lug on the shield drain wire or wrap the shield drain wire around the mounting screw Do not con...

Страница 12: ...of the junction box 6 Pull out the controller terminal strip and connect the three wires to the terminal strip as follows see Figure 5 Connect the positive wire to the PWR SIG terminal Connect the si...

Страница 13: ...mitter and place the transmitter into normal operation Introducing Incoming Power 1 Complete the installation procedures described earlier in this manual 2 Verify that the power wiring to the controll...

Страница 14: ...Plug the voltmeter leads into the test points on the amplifier Plug the positive lead into the red test point plug the negative lead into the black test point 5 Verify a voltmeter reading of 100 mV 2...

Страница 15: ...urately set the zero or response reading during calibration Transmitter requires frequent calibration Note Under normal circumstances the transmitter requires calibration once every 3 months Some appl...

Страница 16: ...n tape to the hub and or detector threads to seal them 8 Connect the detector leads to the terminal block the same way the old detector was wired see Figure 4 on page 11 9 Screw the calibration cup sp...

Страница 17: ...ow zero depending on the setting of the zero pot Be sure to make arrangements so that this does not cause unwanted alarms 10 Turn on or plug in power to the controller 11 Turn on the controller and pl...

Страница 18: ...se time of the detector will depend on the length of flexible tubing that is attached to the calibration cup splash guard To determine the response time based on the length of tubing connected 1 Place...

Страница 19: ...rea is determined to be non hazardous Keep the junction box cover tightly closed during operation 1 Unscrew and remove the junction box cover 2 Set a voltmeter to measure in the millivolt mV range 3 P...

Страница 20: ...r the length of time determined in Determining Response Time on page 18 and verify that the reading matches the response reading 2 mV you determined earlier If necessary use the span pot on the amplif...

Страница 21: ...steel 81 0007RK 01 Steel calibration cylinder 15 LEL hexane in air 34 liter steel 81 0012RK 01 Steel calibration cylinder 50 LEL methane in air 34 liter steel 81 0076RK 01 Steel calibration cylinder...

Отзывы: