65-2405RK-05-04 Combustible Gas Transmitter • 3

Product Warranty

RKI Instruments, Inc. warrants gas alarm equipment sold by us to be free from defects in materials, 
workmanship, and performance for a period of one year from date of shipment from RKI Instruments, 
Inc. Any parts found defective within that period will be repaired or replaced, at our option, free of 
charge. This warranty does not apply to those items which by their nature are subject to deterioration 
or consumption in normal service, and which must be cleaned, repaired, or replaced on a routine basis. 
Examples of such items are:

Warranty is voided by abuse including mechanical damage, alteration, rough handling, or repair 
procedures not in accordance with the operator’s manual. This warranty indicates the full extent of our 
liability, and we are not responsible for removal or replacement costs, local repair costs, transportation 
costs, or contingent expenses incurred without our prior approval.

THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER 
WARRANTIES AND REPRESENTATIONS, EXPRESSED OR IMPLIED, AND 
ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF RKI 
INSTRUMENTS, INC. INCLUDING BUT NOT LIMITED TO, THE WARRANTY 
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO 
EVENT SHALL RKI INSTRUMENTS, INC. BE LIABLE FOR INDIRECT, 
INCIDENTAL, OR CONSEQUENTIAL LOSS OR DAMAGE OF ANY KIND 
CONNECTED WITH THE USE OF ITS PRODUCTS OR FAILURE OF ITS 
PRODUCTS TO FUNCTION OR OPERATE PROPERLY.

This warranty covers instruments and parts sold to users by authorized distributors, dealers, and 
representatives as appointed by RKI Instruments, Inc.

We do not assume indemnification for any accident or damage caused by the operation of this gas 
monitor, and our warranty is limited to the replacement of parts or our complete goods.

a) Absorbent cartridges

d) Batteries

b) Pump diaphragms and valves

e) Filter elements

c) Fuses

Содержание 65-2405RK-05-04

Страница 1: ...RKI Instruments Inc www rkiinstruments com 65 2405RK 05 04 Combustible Gas Transmitter Operator s Manual Part Number 71 0547 Revision P1 Released 2 1 21...

Страница 2: ...eriodic calibration and maintenance of the detector is essential for proper operation and correct readings Please calibrate and maintain this detector regularly Frequency of calibration depends upon t...

Страница 3: ...replacement costs local repair costs transportation costs or contingent expenses incurred without our prior approval THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES AND REPRESENTATI...

Страница 4: ...Detector to the Amplifier 12 Wiring the Amplifier to a Controller 12 Startup 13 Introducing Incoming Power 13 Setting the Zero Signal 14 Maintenance 14 Preventive Maintenance 14 Troubleshooting 15 Re...

Страница 5: ...tation for installation instructions WARNING When using the 65 2405RK 05 04 you must follow the instructions and warnings in this manual to assure proper and safe operation of the 65 2405RK 05 04 and...

Страница 6: ...end allowing ambient air to diffuse into the detector The flame arrestor also contains any sparks which may occur within the detector The 1 2 NPT mounting threads at the top of the detector allow you...

Страница 7: ...lug in style terminal strip located near the top of the amplifier Use the controller terminal strip to wire the transmitter to a controller Detector Terminal Strip The detector terminal strip is a fou...

Страница 8: ...installed remotely from the amplifier junction box The combustible gas detector is factory installed in the bottom 3 4 NPT conduit hub A terminal strip is provided for wiring connections and the detec...

Страница 9: ...g down see Figure 3 3 Install 3 16 inch I D flexible polyurethane tubing to the fitting at the bottom of the calibration cup splash guard and route it to an accessible area that is close to the amplif...

Страница 10: ...tector junction box s cover to the junction box 7 Guide the other end of the four conductor shielded cable or four wires in conduit through the bottom conduit hub of the amplifier junction box 8 To ga...

Страница 11: ...at the amplifier junction box The amplifier mounting screw is a convenient grounding location Install a lug on the shield drain wire or wrap the shield drain wire around the mounting screw Do not con...

Страница 12: ...of the junction box 6 Pull out the controller terminal strip and connect the three wires to the terminal strip as follows see Figure 5 Connect the positive wire to the PWR SIG terminal Connect the si...

Страница 13: ...mitter and place the transmitter into normal operation Introducing Incoming Power 1 Complete the installation procedures described earlier in this manual 2 Verify that the power wiring to the controll...

Страница 14: ...Plug the voltmeter leads into the test points on the amplifier Plug the positive lead into the red test point plug the negative lead into the black test point 5 Verify a voltmeter reading of 100 mV 2...

Страница 15: ...urately set the zero or response reading during calibration Transmitter requires frequent calibration Note Under normal circumstances the transmitter requires calibration once every 3 months Some appl...

Страница 16: ...n tape to the hub and or detector threads to seal them 8 Connect the detector leads to the terminal block the same way the old detector was wired see Figure 4 on page 11 9 Screw the calibration cup sp...

Страница 17: ...ow zero depending on the setting of the zero pot Be sure to make arrangements so that this does not cause unwanted alarms 10 Turn on or plug in power to the controller 11 Turn on the controller and pl...

Страница 18: ...se time of the detector will depend on the length of flexible tubing that is attached to the calibration cup splash guard To determine the response time based on the length of tubing connected 1 Place...

Страница 19: ...rea is determined to be non hazardous Keep the junction box cover tightly closed during operation 1 Unscrew and remove the junction box cover 2 Set a voltmeter to measure in the millivolt mV range 3 P...

Страница 20: ...r the length of time determined in Determining Response Time on page 18 and verify that the reading matches the response reading 2 mV you determined earlier If necessary use the span pot on the amplif...

Страница 21: ...steel 81 0007RK 01 Steel calibration cylinder 15 LEL hexane in air 34 liter steel 81 0012RK 01 Steel calibration cylinder 50 LEL methane in air 34 liter steel 81 0076RK 01 Steel calibration cylinder...

Отзывы: