 Use the solderless terminal appropriate to the screw size. 

- Screw size: 

M3 x 6 

- Recommended tightening torque: 0.4 N

m [4 kgf

cm] 

- Specified solderless terminals: 

With isolation 

 
 
 
 
 

 Make sure that during field wiring parts of conductors can not 

come into contact with adjacent conductive parts. 

 
 

6.2 Terminal Configuration 

 

CT1 

T/R(B) 

SG 

T/R(A) 

RS-485 

Host 

communication 

CT input 

Control output 1 

Control output 2

15

Relay contact 

NO 

OUT1 

Voltage pulse/

Current/ 

Voltage 

OUT1 

 

 

16

17

 

 

24 V 

DC 

Power supply 

Ground 

Thermocouple 

TC1 

 

 

Input channel 1

Voltage/ 

Current 

IN1 

 

 

RTD 

RTD1 

NO

OUT2

OUT2 

 

 

4

1

10

13

10

14

13

13

10

TC2 

 

 

IN2 

 

 

12

8

12

12

RTD2

B

A

Input channel 2

19

18

20

FG 

16  15 

2

17 

5

20  19  14  13

12 

18  11  10 

9

Upper-side terminal

CT2 

Relay contact

Voltage pulse/

Current/ 

Voltage 

Lower-side terminal

Thermocouple 

RTD

Voltage/ 

Current 

Voltage/ 

Current 

 

 

 

 

Heater break alarm (HBA) function cannot be used 
when control output is Voltage/Current output. 

 

  Terminal No. 11 is not used. 

 

Input channel 2 can be used as remote setting input 
(only for Voltage/Current input). In this case, control 
output 2 and CT input 2 become unused.

 

 
 

6.3 Pin Layout of Connector 

 

Modular connector 

 

Modular connector 

6

1

..

..

..

..

..

..

COM. PORT1

COM. PORT2

COM. PORT3

 

 
Modular connector

 COM. PORT1: 

Connector for PLC or Host computer connection 
Based on RS-422A/RS-232C (Specify when ordering) 

Modular connector

 COM. PORT2: 

Connector for PLC or Host computer connection 
Based on RS-422A 

Modular connector

 COM. PORT3: 

Connector for SRX unit extension 
Based on RS-422A 

 

* RS-422A 

Pin No. 

Signal name 

Symbol 

Receive data 

R (A) 

Receive data 

R (B) 

3 Signal 

ground SG 

Send data 

T (B) 

Send data 

T (A) 

6 Signal 

ground SG 

 

* RS-232C 

Pin No. 

Signal name 

Symbol 

1 Unused 

 

Send data 

SD (TXD) 

3 Signal 

ground SG 

Receive data 

RD (RXD) 

5 Unused 

 

6 Signal 

ground SG 

 

Customer is requested to prepare a communication 
cable fit for the X-TIO-R module to be connected by the 
host computer or PLC. 
Connection cable W-BF-01*, W-BF-02 * and W-BF-28 
(RKC product) can use to connect the host computer or 
PLC. 

*  Shields of the cable are connected to SG (No. 6 pin) of 

the X-TIO-R connector. 

 

The 6-pin type modular connector should be used for 
the connection to the X-TIO-R module. 
Recommended model:   

TM4P-66P 

(Manufactured by HIROSE ELECTRIC CO., LTD.)

 

 
 

 

5.9 mm or less 

3.2 mm or more 

Содержание X-TIO-R

Страница 1: ...y operating personnel All precautions described in this manual should be taken to avoid damage to the instrument or equipment All wiring must be in accordance with local codes and regulations All wiring must be completed before power is turned on to prevent electric shock instrument failure or incorrect action The power must be turned off before repairing work for input break and output failure in...

Страница 2: ...Extension type X TIO B Digital input DI module X DI A X DI B Digital output DO module X DO A X DO B Up to 29 modules Temperature control module for PLC communication X TIO R For communication port assignments refer to the 4 2 Protocol Selections and Communication Speed Setting P 5 All data are set by communication For details refer to the Module Type Controller SRX PLC Host Communication Instructi...

Страница 3: ...l cover Indication lamps 2 Modular connector COM PORT1 Modular connector COM PORT2 Modular connector COM PORT3 FAIL RUN RX TX EVENT1 EVENT2 EVENT3 EVENT4 PLC host communication side Temperature control side 5 4 3 2 1 0 9 8 7 6 5 5 4 3 2 1 0 9 8 7 6 5 FAIL RUN RX TX EVENT1 EVENT2 EVENT3 EVENT4 Indication lamps 1 FAIL RUN for temperature control When normally A green lamp turns on RUN When abnormall...

Страница 4: ...ctor Host communication setting switch 1 right side Refer to P 6 Set the communication speed data bit configuration and protocol for host communication using host communication terminals Set the same value as communication settings of host computer Host communication setting switch 1 PLC communication setting switch Host communication setting switch 2 Address setting switch 2 Address setting switc...

Страница 5: ...tory set value Host communication 2 RKC communication 8 Communication port assignment OFF COM PORT1 PLC communication host communication 2 RS 232C RS 422A COM PORT2 COM PORT3 Host communication 1 RS 422A ON COM PORT1 Host communication 1 RS 232C RS 422A COM PORT2 COM PORT3 PLC communication host communication 2 RS 422A Factory set value COM PORT1 Host communication 1 RS 232C RS 422A COM PORT2 COM ...

Страница 6: ...lection OFF RKC communication ON Modbus Factory set value RKC communication 8 Internal data bus termination resistor setting OFF Termination resistor OFF ON Termination resistor ON Factory set value Termination resistor OFF Switch No 7 must be always OFF Do not set to ON When connecting two or more modules TIO module Extension type etc to the X TIO R module match all of their communication speed d...

Страница 7: ... the immunity to withstand noise mount this instrument as far away as possible from high voltage equipment power lines and rotating machinery High voltage equipment Do not mount within the same panel Power lines Separate at least 200 mm Rotating machinery Separate as far as possible Ensure at least 50 mm space on top and bottom of the control unit for maintenance and environmental reasons 5 In cas...

Страница 8: ...tab insertion slot 6 WIRING 6 1 Wiring Cautions For thermocouple input use the appropriate compensation wire For RTD input use low resistance lead wire with no difference in resistance between the three lead wires To avoid noise induction keep input signal wire away from instrument power line load lines and power lines of other electric equipment Signal connected to Voltage input and Current input...

Страница 9: ...g input only for Voltage Current input In this case control output 2 and CT input 2 become unused 6 3 Pin Layout of Connector Modular connector Modular connector 6 1 COM PORT1 COM PORT2 COM PORT3 Modular connector COM PORT1 Connector for PLC or Host computer connection Based on RS 422A RS 232C Specify when ordering Modular connector COM PORT2 Connector for PLC or Host computer connection Based on ...

Страница 10: ...nction Events Number of events 2 points channel Event type Temperature event Deviation high Deviation low Deviation high low Band Process high Process low Heater break alarm HBA function Number of HBA 2 points Setting range 0 0 to 100 0 A 0 0 A OFF Additional function Number of event delay times 1 to 255 times Control loop break alarm LBA function Number of LBA 2 points LBA time 1 to 7200 seconds ...

Отзывы: