5. MOUNTING 

 
 
 
 
 
 
 

5.1 Mounting Cautions 

(1) This instrument is intended to be used under the following 

environmental conditions. 

(IEC61010-1)

   

[OVERVOLTAGE CATEGORY II, POLLUTION DEGREE 2]

 

(2)  Use this instrument within the following environment conditions. 

  Allowable ambient temperature: 

10 to 

50 

  Allowable ambient humidity: 5 to 95 %RH 

(Absolute humidity: MAX. W. C 29.3 g/m

3

 dry air at 101.3 kPa) 

  Installation environment conditions:  Indoor use   

 

Altitude up to 2000 m 

(3)  Avoid the following when selecting the mounting location:

 

  Rapid changes in ambient temperature, which may cause 

condensation. 

  Corrosive or inflammable gases. 

  Direct vibration or shock to the mainframe. 

  Water, oil, chemicals, vapor or steam splashes. 

  Excessive dust, salt or iron particles. 

  Excessive induction noise, static electricity, magnetic fields or 

noise. 

  Direct air flow from an air conditioner. 

  Exposure to direct sunlight. 

  Excessive heat accumulation. 

(4) Mount this instrument in the panel considering the following 

conditions: 

  Provide adequate ventilation space so that heat does not build up. 

 Do not mount this instrument directly above equipment that 

generates large amount of heat (heaters, transformers, 
semi-conductor functional devices, large-wattage resistors.) 

  If the ambient temperature rises above 50 

C, cool this instrument 

with a forced air fan, cooler, etc. Cooled air should not blow 
directly on this instrument. 

  In order to improve safety and the immunity to withstand noise, 

mount this instrument as far away as possible from high 
voltage equipment, power lines, and rotating machinery. 

High voltage equipment: 
 

Do not mount within the same panel. 

Power lines: 

Separate at least 200 mm. 

Rotating machinery: Separate as far as possible. 

  Ensure at least 50 mm space on top and bottom of the control 

unit for maintenance and environmental reasons. 

(5)  In case this instrument is connected to a supply by means of a 

permanent connection, a switch or circuit-breaker shall be 
included in the installation. This shall be in close proximity to 
the equipment and within easy reach of the operator. It shall 
be marked as the disconnecting device for the equipment. 

 

 

5.2 Dimensions 

(Unit: mm) 

 

110

6.8

40.5

125

 

78

 

5

 

 

5.3 DIN rail Mounting 

 

Mounting procedures 

1. 

Pull down the mounting bracket at the bottom of the module (A). 
Attach the hooks on the top of the module to the DIN rail and 
push the lower section into place on the DIN rail (B).   

 

(B) Push

Mounting 

bracket

DIN rail

(A) Pull down 

 

 

2. 

Slide the mounting bracket up to secure the module to the 
DIN rail. 

 

Locked 

 

 
 

 

End Plate mounting 

Hold tight both ends of the modules jointed together with the end 
plates and then fix the end plates with screws. Even if only one 
X-TIO-R module is used, also hold tight both ends of the module 
with the end plates. 

 

End Plate

X-TIO-R module 

End Plate

Joint connector cover 

*

 

 

For the conservation of the contact of connector, install a 
joint connector cover in module of both ends.

 

   

   

To prevent electric shock or instrument failure, 
always turn off the power before mounting or 
removing the instrument. 

!

 

WARNING 

Содержание X-TIO-R

Страница 1: ...y operating personnel All precautions described in this manual should be taken to avoid damage to the instrument or equipment All wiring must be in accordance with local codes and regulations All wiring must be completed before power is turned on to prevent electric shock instrument failure or incorrect action The power must be turned off before repairing work for input break and output failure in...

Страница 2: ...Extension type X TIO B Digital input DI module X DI A X DI B Digital output DO module X DO A X DO B Up to 29 modules Temperature control module for PLC communication X TIO R For communication port assignments refer to the 4 2 Protocol Selections and Communication Speed Setting P 5 All data are set by communication For details refer to the Module Type Controller SRX PLC Host Communication Instructi...

Страница 3: ...l cover Indication lamps 2 Modular connector COM PORT1 Modular connector COM PORT2 Modular connector COM PORT3 FAIL RUN RX TX EVENT1 EVENT2 EVENT3 EVENT4 PLC host communication side Temperature control side 5 4 3 2 1 0 9 8 7 6 5 5 4 3 2 1 0 9 8 7 6 5 FAIL RUN RX TX EVENT1 EVENT2 EVENT3 EVENT4 Indication lamps 1 FAIL RUN for temperature control When normally A green lamp turns on RUN When abnormall...

Страница 4: ...ctor Host communication setting switch 1 right side Refer to P 6 Set the communication speed data bit configuration and protocol for host communication using host communication terminals Set the same value as communication settings of host computer Host communication setting switch 1 PLC communication setting switch Host communication setting switch 2 Address setting switch 2 Address setting switc...

Страница 5: ...tory set value Host communication 2 RKC communication 8 Communication port assignment OFF COM PORT1 PLC communication host communication 2 RS 232C RS 422A COM PORT2 COM PORT3 Host communication 1 RS 422A ON COM PORT1 Host communication 1 RS 232C RS 422A COM PORT2 COM PORT3 PLC communication host communication 2 RS 422A Factory set value COM PORT1 Host communication 1 RS 232C RS 422A COM PORT2 COM ...

Страница 6: ...lection OFF RKC communication ON Modbus Factory set value RKC communication 8 Internal data bus termination resistor setting OFF Termination resistor OFF ON Termination resistor ON Factory set value Termination resistor OFF Switch No 7 must be always OFF Do not set to ON When connecting two or more modules TIO module Extension type etc to the X TIO R module match all of their communication speed d...

Страница 7: ... the immunity to withstand noise mount this instrument as far away as possible from high voltage equipment power lines and rotating machinery High voltage equipment Do not mount within the same panel Power lines Separate at least 200 mm Rotating machinery Separate as far as possible Ensure at least 50 mm space on top and bottom of the control unit for maintenance and environmental reasons 5 In cas...

Страница 8: ...tab insertion slot 6 WIRING 6 1 Wiring Cautions For thermocouple input use the appropriate compensation wire For RTD input use low resistance lead wire with no difference in resistance between the three lead wires To avoid noise induction keep input signal wire away from instrument power line load lines and power lines of other electric equipment Signal connected to Voltage input and Current input...

Страница 9: ...g input only for Voltage Current input In this case control output 2 and CT input 2 become unused 6 3 Pin Layout of Connector Modular connector Modular connector 6 1 COM PORT1 COM PORT2 COM PORT3 Modular connector COM PORT1 Connector for PLC or Host computer connection Based on RS 422A RS 232C Specify when ordering Modular connector COM PORT2 Connector for PLC or Host computer connection Based on ...

Страница 10: ...nction Events Number of events 2 points channel Event type Temperature event Deviation high Deviation low Deviation high low Band Process high Process low Heater break alarm HBA function Number of HBA 2 points Setting range 0 0 to 100 0 A 0 0 A OFF Additional function Number of event delay times 1 to 255 times Control loop break alarm LBA function Number of LBA 2 points LBA time 1 to 7200 seconds ...

Отзывы: