3. PARTS DESCRIPTION 

 

Terminal cover

Indication lamps 1

Address setting

switch 1 

Terminal cover

Indication lamps 2 

Modular connector 

COM. PORT1 

Modular connector 

COM. PORT2 

Modular connector 

COM. PORT3 

5

4

3

2

1

0

9 8 7

6

5

5

4

3

2

1

0

9 8 7

6

5

FAIL/RUN
RX/TX 
EVENT1
EVENT2
EVENT3
EVENT4

Event  

input/output 

connector 

*

 

PLC/host communication side Temperature control side 

 

 

 

 

FAIL/RUN 
RX/TX 
EVENT1 
EVENT2 
EVENT3 
EVENT4 

 

 
 
 
[Indication lamps 1] 

 

FAIL/RUN (for temperature control) 

When normally: 

A green lamp turns on (RUN) 

When abnormally: 

A red lamp turns on (FAIL) 

During self-diagnostic error: A green lamp flashes   

 

RX/TX (for internal communication) 

During data send and receive: A green lamp turns on 

 

EVENT 1 to 4 

Display various states by setting. 

Display contents: 
Event 1 state, Event 2 state, Comprehensive event state, Output 
state, Control state 

[Indication lamps 2] 

 

FAIL (for PLC/host communication) 

When normally: 

A red lamp turns off 

When abnormally: 

A red lamp turns on 

Communication environment setting mode by the switch: 
 

A red lamp flashes 

 

RUN (for PLC/host communication) 

When normally: 

A green lamp turns on 

When abnormally: 

A green lamp turns off 

Memory backup error: 

A green lamp flashes slowly 

Module configuration error:  A green lamp flashes slowly 
PLC communication error:  A green lamp flashes slowly 
Data collection just after the power is turned on: 
 

A green lamp flashes rapidly 

 

COM. PORT1 

During data send and receive: A yellow lamp turns on 

 

COM. PORT2/ COM. PORT3 

During data send and receive: A yellow lamp turns on 

 
 

4. COMMUNICATION SETTING 

Set communication setting before mounting and wiring of SRV. 
 
 

Do not separate the module mainframe from the terminal 
base with the power turned on. If separated, adjusted data 
may be destroyed; control be stopped, and no return can be 
made. 

 

 

 

Setting at using PLC communication   

 Address setting switch 1 (front) [See P. 5]

 

Set an address of module. 

 Address setting switch 2 (left side) [See P. 5]

 

Set the unit address for PLC communication. 

 PLC communication setting switch (left side) [See P. 5]

 

Set the communication speed, data bit configuration, and 
protocol for PLC communication. Set the same value as 
communication settings of PLC. 
In addition, select the communication port of modular 
connector. 

 Internal communication setting switch (right side) [See P. 6]

 

Use this module without changing the factory set values. 

 
 

 

Setting at using host communication 1 

 Address setting switch 1 (front) [See P. 5]

 

Set an address of module. 

 Address setting switch 2 (left side) [See P. 5]

 

Set the unit address for host communication 1. 

 

PLC communication setting switch (left side) [See P. 5]

 

Select the communication port of modular connector. 

 Host communication setting switch (left side) [See P. 6]

 

Set the communication speed, data bit configuration, and 
protocol for host communication 1. Set the same value as 
communication settings of host computer. 

 Internal communication setting switch (right side) [See P. 6]

 

Use this module without changing the factory set values. 

 
 

 

Setting at using host communication 2 

 Address setting switch 1 (front) [See P. 5]

 

Set an address of module. 

 Address setting switch 2 (left side) [See P. 5]

 

Set the unit address for host communication 2. 

 PLC communication setting switch (left side) [See P. 5]

 

Set the communication speed, data bit configuration, and 
protocol for host communication 2. Set the same value as 
communication settings of host computer. 
In addition, select the communication port of modular 
connector. 

 Internal communication setting switch (right side) [See P. 6]

 

Use this module without changing the factory set values. 

 

 

 

5

4

3

2

1

0

9 8 7

6

5

5

4

3

2

1

0

9 8 7

6

5

FAIL/RUN 
RX/TX 
EVENT1 
EVENT2 
EVENT3 
EVENT4 

Internal communication 

setting switch 

PLC communication setting switch 

Host communication setting switch 

Address setting switch 2

Address setting switch 1

Left side

Right side

Front 

Module mainframe 

Terminal base 

 

Installed when provided with the event input/output (optional).

Indication 
lamp 2 

Indication
lamp 1 

Temperature control side

PLC/host communication side

FAIL 
RUN 
COM. PROT1 
COM. PROT2/COM. PROT3 

CAUTION

Содержание V-TIO-E

Страница 1: ...osed instrumentation panel All high voltage connections such as power supply terminals must be enclosed in the instrumentation panel to avoid electric shock by operating personnel All precautions desc...

Страница 2: ...groups and then installed Usable modules Temperature control TIO module Basic type V TIO A C Temperature control TIO module Extension type V TIO B D Up to 30 modules Event input output connector optio...

Страница 3: ...JPt100 P17 0 to 400 C PC5 32 to 752 F P23 0 to 600 C PC4 32 to 1112 F P16 0 0 to 400 0 C PC7 32 0 to 752 0 F P28 200 0 to 400 0 C PC6 328 0 to 752 0 F Voltage current input Code Type Code Type Voltage...

Страница 4: ...e See P 5 Set the unit address for PLC communication PLC communication setting switch left side See P 5 Set the communication speed data bit configuration and protocol for PLC communication Set the sa...

Страница 5: ...imal Factory set value 0 9 8 7 C B A 6 543 2 1 0 F E D Address setting switch 2 for unit address PLC communication Up to four V TIO E F modules can be connected to a PLC communication port Therefore t...

Страница 6: ...ps ON ON 38400 bps Factory set value 9600 bps 3 4 5 Data bit configuration OFF OFF OFF Data 7 bit without parity Stop 1 bit OFF OFF ON Data 7 bit Even parity Stop 1 bit OFF ON OFF Don t set this one O...

Страница 7: ...y reach of the operator It shall be marked as the disconnecting device for the equipment 5 2 Dimensions Unit mm 110 6 8 40 5 125 78 5 The above figure shows when provided with the event input output c...

Страница 8: ...se induction keep input signal wire away from instrument power line load lines and power lines of other electric equipment If there is electrical noise in the vicinity of the instrument that could aff...

Страница 9: ...e modular connector should be used for the connection to the V TIO E F module Recommended manufacturer and model Hirose Electric TM4P 66P Event input output connector 1 6 Event input output connector...

Страница 10: ...low Deviation high low Band Process high Process low Heater break alarm Control loop break alarm Burnout Temperature rise completion Option Event input Number of inputs 1 point Input type Dry contact...

Отзывы: