3.5.6 Connection configuration
-
IO interface module
Inputs
Terminal Function
I1
-
I8*
1
-
8
n
High:
5
-
30 VDC
n
Low:
0
-
2 VDC
1
1
UP:
When the high level is active, a movement is made towards the maximum
position.
2
2
DOWN:
When the high level is active, a movement is made towards the minimum
position.
3
3
Action enabled from 3-bit mask (inputs 4
-
6)
4
-
6
4
-
6
3-bit mask for memory slot
7
7
Speed (s/l):
Changes the speed (fast/slow) of the system. If the high level is
active, crawl speed is activated.
The speed is set using parameter 17
.
8
8
Reset error:
Resets the active status of an error if possible.
RS485 A/B
9, 10
Control BUS A/B
U
digital input
**
11
Logic V+, 9
-
15 VDC, max. 40 mA
12
GND
* Input voltage level
** The voltage supply for digital inputs
Inputs ( )
Fig. 15: IO interface module inputs