![RK Rose+Krieger RK MultiControl II duo Скачать руководство пользователя страница 146](http://html1.mh-extra.com/html/rk-rose-krieger/rk-multicontrol-ii-duo/rk-multicontrol-ii-duo_assembly-instructions-manual_1466556146.webp)
Inputs
Position
6
5
4
0
0
0
Start initialization run
0
0
1
Drive to memory position 1
0
1
0
Drive to memory position 2
0
1
1
Drive to memory position 3
1
0
0
Drive to memory position 4
1
0
1
Drive to memory position 5
1
1
0
Drive to memory position 6
1
1
1
Drive to memory position 7
Start initialization run:
If the high level is active, an initialization run is triggered. The initi-
alization is carried out with the UP and DOWN inputs in accord-
ance with the set mode.
Drive to memory position:
Starts the movement towards the memory position from the table
3-bit mask for memory slot
Set-up and function
Connections > Connection configuration
-
IO interface module