RJM MasterMind Скачать руководство пользователя страница 22

 

16

 

 
Watching the display, you’ll see that it alternates between displaying the current preset number, 

PC1

 and a program 

change number. If you’re on preset 001 and haven’t changed anything from the defaults, you’ll see it alternate between  

P001

,

 PC1

 and 

=001

. This means that, for preset 001, it will send program change #1 to PC1. (Remember that PC1 is a 

destination for Program Change messages and was set to a specific MIDI channel in 

Global Setup

). 

 
The LED above the 

2 / Program/CC Number

 button will be lit, indicating that it can be used to change the program 

number. Pressing this button will increment the program number by 1, until it reaches 128 (the maximum). Pressing it 
again will set the program number back to the minimum, which is 

=001

 
(

Important Note:

 Some MIDI devices use program numbers 1 through 128 and some use program numbers 0 through 

127. If your device is one of the latter, your program numbers will be off by 1. Selecting program 1 on the MasterMind 
will cause the device to select program 0. Selecting program 2 on the MasterMind will cause the device to select 
program 1, etc.) 
 
All the other Preset parameters can be edited in this way.  Pressing the 

1 / Function Select

 button will move you to the 

next parameter. If a parameter has been disabled in Global Setup (for example if 

PC2

 is set to 

CH--

), it will not appear in 

Preset Setup. Once you reach the end of the parameter list, pressing  

1 / Function Select 

again will bring you back to 

the first parameter in the list. 
 
The Preset parameters are as follows: 
 

PC1 

-   Program Change #1 

(Program Change number range: 

=001 

=128

,

 =---

 (

send no PC

), Default value: preset 001 defaults to 

=001

preset 002 defaults to 

=002

, preset 003 defaults to 

=003 

etc. ) 

Sets the program number for the first Program Change destination. Press 

2 / Program/CC Number 

to select the 

program number. 
 

PC2 

-   Program Change #2 

(Program Change number range: 

=001 

=128

,

 =---

 (

send no PC

), Default value 

=001

Sets the program number for the second Program Change destination. Press 

2 / Program/CC Number 

to select the 

program number. 
 

PC3 

-   Program Change #3 

(Program Change number range: 

=001 

=128

,

 =---

 (

send no PC

), Default value 

=001

Sets the program number for the third Program Change destination. Press 

2 / Program/CC Number 

to select the 

program number. 

 
PC4 

-   Program Change #4 

(Program Change number range: 

=001 

=128

,

 =---

 (

send no PC

), Default value 

=001

Sets the program number for the fourth Program Change destination. Press 

2 / Program/CC Number 

to select the 

program number. 

 
FunC

 -  Function Button 

 

(MIDI Ch range: 

CH01 

CH16

CH-- 

(Function button disabled) 

, Default value: 

CH01

 

(CC number range: 

c000

 - 

c127

, Default value: 

c000

Sets the Continuous Controller message sent by the Function button for this preset. If bank support is enabled (see 

Global Setup

), 

c000 

will be displayed instead as 

ban

 (bank). Setting this parameter to 

ban 

will enable the Alternate 

Preset feature for this preset (see 

Alternate Presets

 section). Setting it to any other value will cause normal Continuous 

Controller messages to be sent. Press 

2 / Program/CC Number 

to select the Continuous Controller number, press 

5 / 

MIDI Ch 

to select the MIDI Channel. 

 

PDL

 - 

Expression Pedal

 

 

(MIDI Ch range: 

CH01 

CH16

CH-- 

(Expression pedal disabled) 

, Default value: 

CH01

 

(CC number range: 

c000

 - 

c127

, Default value: 

c007

Sets the Continuous Controller message sent by the Expression Pedal for this preset. Press 

2 / Program/CC Number 

to 

select the Continuous Controller number, press 

5 / MIDI Ch 

to select the MIDI Channel. 

 

Содержание MasterMind

Страница 1: ...MasterMind User s Manual RJM Music Technology Inc...

Страница 2: ......

Страница 3: ...s Manual Version 1 6 1 December 6 2010 Corresponds to Mastermind firmware version 1 4 RJM Music Technology Inc 2525 Pioneer Ave Suite 1 Vista CA 92081 1 760 597 9450 email support rjmmusic com web ww...

Страница 4: ...Copyright 2009 2010 RJM Music Technology Inc All Rights Reserved RG 16 Amp Gizmo MasterMind and the RJM logo are trademarks of RJM Music Technology Inc...

Страница 5: ...ts 5 Controlling Multiple RJM Music Products 6 Alternate Presets 6 Instant Access Mode 7 Expression Pedal 8 Pedal Calibration 8 Remote Access 9 Phantom Power 9 Remote Tuner Display 10 Setup Mode 11 En...

Страница 6: ......

Страница 7: ...and can also control devices by use of the Function button and Expression Pedal input MasterMind Features Plug and play operation with other RJM products Transmits up 4 Program Change messages and 8 C...

Страница 8: ...2 Front Panel...

Страница 9: ...3 Rear Panel...

Страница 10: ...power supplies of 9 to 18 volts AC or DC The power supply must be able to deliver at least 200mA The connector is a standard 5 5mm 2 1mm barrel connector and can be either center negative or center p...

Страница 11: ...ll cause the bank number to count up or down automatically When you re done selecting the bank the preset number in the display will flash indicating that you now need to select a preset number Press...

Страница 12: ...sound A004 Drive sound w flanger 005 Solo sound A005 Solo sound w harmonizer With this setup you can press the 1 button to get your clean sound then press Function to turn chorus on or off as desired...

Страница 13: ...ode the MasterMind buttons perform new functions Buttons 1 through 5 pressing one of these buttons will send a continuous controller message Each button press will toggle between on 127 and off 0 valu...

Страница 14: ...dals on the market will work Pedals that have a stereo TRS 1 4 output jack and have the potentiometer wiper connected to the ring conductor of the output jack will definitely work The Rocktron Hex is...

Страница 15: ...MIDI Out jack connected to the rest of your rig When the MasterMinds are turned on you ll notice that all but the first MasterMind will have the Remote indicator lit This means that the controllers ar...

Страница 16: ...t this communication you will need to connect a second MIDI cable from the MIDI output of your effects processor to the Remote In jack of your Mastermind The tuner display automatically turns on when...

Страница 17: ...l flash to tell you that you are now in Setup Mode and will remain flashing until you leave Setup Mode Setup Mode Buttons When in setup mode the buttons secondary functions are active These are the gr...

Страница 18: ...uts you into Global Setup The green LED above the button will light to tell you that Global Setup is active You are now ready to edit the first parameter Watching the display you ll see that it altern...

Страница 19: ...16 CH CC5 disabled Default value CH CC number range c000 c127 Default value c084 Sets the MIDI channel and CC number for the fifth Continuous Controller destination Press 2 Program CC Number to select...

Страница 20: ...5 etc IA Instant Access Instant Access range On OFF Default value OFF Turning on this parameter will enable Instant Access mode With this parameter on the Function button will activate Instant Access...

Страница 21: ...the MasterMind knows the upper and lower limits of pedal travel which are needed to provide the best pedal performance When in pedal calibration the display will read CAL With the expression pedal plu...

Страница 22: ...t 001 defaults to 001 preset 002 defaults to 002 preset 003 defaults to 003 etc Sets the program number for the first Program Change destination Press 2 Program CC Number to select the program number...

Страница 23: ...for the fifth Continuous Controller destination Press 4 CC Value to set the value or press 3 CC On Off to quickly toggle between the most commonly used values 000 and 127 CC6 Continuous Controller 6 C...

Страница 24: ...e receiving unit then enter Global Setup select the Send parameter and press Bank Up Note that the receiving MasterMind must be in normal operating mode to receive data The receiving unit s display wi...

Страница 25: ...hantom Power Accepted over pins 6 and 7 of the MIDI Out jack same specs as above Phantom power is passed over pins 6 and 7 of the Remote In jack current limited to 500mA Do not connect phantom power a...

Страница 26: ...n GM2 System On Yes No Turn GM System Off Yes No DLS 1 Yes No File Reference Yes No Controller Destination Yes No Key based Instrument Ctrl Yes No Master Fine Coarse Tune Yes No Other Universal System...

Страница 27: ...Y N 17 General Purpose Controller 2 MSB Y N 18 General Purpose Controller 3 MSB Y N 19 General Purpose Controller 4 MSB Y N 20 Y N 21 Y N 22 Y N 23 Y N 24 Y N 25 Y N 26 Y N 27 Y N 28 Y N 29 Y N 30 Y...

Страница 28: ...CC1 default 81 General Purpose Controller 6 Y N CC2 default 82 General Purpose Controller 7 Y N CC3 default 83 General Purpose Controller 8 Y N CC4 default 84 Portamento Control Y N CC5 default 85 Y N...

Страница 29: ......

Отзывы: