![RJG Lynx LE-R-50-REVB Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/rjg/lynx-le-r-50-revb/lynx-le-r-50-revb_product-manual_1466484017.webp)
Product Manual | Lynx™ 50-Inch Stroke/Velocity Sensor LE-R-50-REVB
11
TROUBLESHOOTING
COMMON INSTALLATION ERRORS
1.
Cable Interference
The stroke/velocity sensor is installed
so that there is interference along the
cable path. Cable interference will cause
premature cable wear and erroneous
readings.
Remove sensor, then refer to “Installation
Specifications” on page 3 to re‑install
the sensor correctly.
2.
Cable is Angled
The stroke/velocity sensor is installed so
that the cable exit/enters the sensor body
at an angle instead of straight (
1
&
2
below). Sensor operation with the cable
at an angle will cause erroneous readings
and premature wear on the nylon cable
bushing.
Remove the sensor, then refer to
“Installation Specifications” on page 3
to re‑install the sensor correctly.
1
2
Содержание Lynx LE-R-50-REVB
Страница 2: ...PRINT DATE REVISION NO 08 24 2021 1 ...
Страница 6: ...Lynx 50 Inch Stroke Velocity Sensor LE R 50 REVB Product Manual iv ...
Страница 8: ...Lynx 50 Inch Stroke Velocity Sensor LE R 50 REVB Product Manual 2 DIMENSIONS ...
Страница 14: ...Lynx 50 Inch Stroke Velocity Sensor LE R 50 REVB Product Manual 8 ...
Страница 16: ...Lynx 50 Inch Stroke Velocity Sensor LE R 50 REVB Product Manual 10 ...
Страница 20: ...Lynx 50 Inch Stroke Velocity Sensor LE R 50 REVB Product Manual 14 ...
Страница 21: ......