RJG Lynx ID7-M-SEQ Скачать руководство пользователя страница 5

Product Manual | Lynx™ Shielded Sequence Module ID7‑M‑SEQ

RJG, Inc.

iii

INTRODUCTION

Read, understand, and comply with all following 
instructions. This guide must be kept available 
for reference at all times.

DISCLAIMER

Inasmuch as RJG, Inc. has no control over the 
use to which others may put this material, it 
does not guarantee that the same results as 
those described herein will be obtained. Nor 
does RJG, Inc. guarantee the effectiveness or 
safety of any possible or suggested design for 
articles of manufacture as illustrated herein by 
any photographs, technical drawings, and the 
like. Each user of the material or design or 
both should make his own tests to determine 
the suitability of the material or any material 
for the design as well as the suitability of the 
material, process, and/or design for his own 
particular use. Statements concerning possible 
or suggested uses of the material or designs 
described herein are not to be construed as 
constituting a license under any RJG, Inc. patent 
covering such use or as recommendations 
for use of such material or designs in the 
infringement of any patent.

PRIVACY

Designed and developed by RJG, Inc. Manual 
design, format and structure copyright 2018 
RJG, Inc. content documentation copyright 
2018 RJG, Inc. All rights reserved. Material 
contained herein may not be copied by hand, 
mechanical, or electronic means, either whole 
or in part, without the express written consent 
of RJG, Inc. Permission will normally be granted 
for use in conjunction with inter‑company use 
not in conflict with RJG’s best interests.

ALERTS

The following three alert types are used as 
needed to further clarify or highlight information 
presented in the manual:

Term 

A definition of a term or terms used in the 

text.

NOTE 

A note provides additional information 

about a discussion topic.

CAUTION 

A caution is used to make the 

operator aware of conditions that can cause 

damage to equipment and/or injury to personnel.

Содержание Lynx ID7-M-SEQ

Страница 1: ...PRODUCT MANUAL Training and Technology for Injection Molding Lynx Shielded Sequence Module ID7 M SEQ...

Страница 2: ...PRINT DATE 12 16 2019 REVISION NO 0...

Страница 3: ...MER III PRIVACY III ALERTS III PRODUCT DESCRIPTION APPLICATIONS 1 PROCESS MONITORING AND CONTROL 1 OPERATION 2 MACHINE SEQUENCE SIGNALS 2 eDART SEQUENCE SIGNALS 4 DIMENSIONS 5 CABLE LENGTHS 5 INSTALLA...

Страница 4: ...ESHOOTING COMMON ERRORS 13 SIGNAL ERRORS 13 ACCEPTABLE SIGNAL SUBSTITUTIONS 14 CUSTOMER SUPPORT 15 RELATED PRODUCTS COMPATIBLE PRODUCTS 17 SHIELDED SEQUENCE MODULE CABLE C ID7 M 3M 17 LYNX CABLES CE L...

Страница 5: ...d uses of the material or designs described herein are not to be construed as constituting a license under any RJG Inc patent covering such use or as recommendations for use of such material or design...

Страница 6: ...Lynx Shielded Sequence Module ID7 M SEQ Product Manual iv RJG Inc...

Страница 7: ...in order to accurately calculate significant process values for monitoring and control The ID7 M SEQ gathers the machine sequence state signals from the injection molding machine for the eDART The eDA...

Страница 8: ...push plastic into the mold and ends when it stops applying pressure when hold begins The eDART uses the injection forward signal as the start of the cycle Without the injection forward signal the eDAR...

Страница 9: ...indicates when the mold is opening during a cycle If the signal is on when the mold is opening assign it as mold opening 7 Manual The manual signal is assigned to indicate the machine s current operat...

Страница 10: ...RT which uses the transfer pressure set in cavity pressure control If cavity pressure control is not in use pack will only exist if the fill signal is considered to be a fill and pack combined signal...

Страница 11: ...Product Manual Lynx Shielded Sequence Module ID7 M SEQ RJG Inc 5 DIMENSIONS CABLE LENGTHS The C ID7 M 3M is 9 8 ft 3 m long CABLE LENGTH...

Страница 12: ...Lynx Shielded Sequence Module ID7 M SEQ Product Manual 6 RJG Inc...

Страница 13: ...able C ID7 M 3M is wired directly to the machine usually to an output card on one end and connected to the ID7 M SEQ on the other using the eight pin connector eDART CONNECTION A Lynx cable CE LX5 is...

Страница 14: ...the signals are misnamed or do not go on and off as specified the system generated machine sequence signals will likely be incorrect as will the data calculated from them Refer to Machine Sequence Si...

Страница 15: ...detects stroke direction zeroes plastic volume at cycle This signal is required Mold Closed Clamped MC Mold Clamped to High Tonnage Mold Begins to Open Primary signal for cycle time calculation zeroin...

Страница 16: ...future software setup and use The C ID7 M 3M cable has colored coded wires to simplify installation Refer to the table below for the correct wire signal combinations for installation SIGNAL WIRING COL...

Страница 17: ...signals select the Sequence Inputs inputs button on the Sequence Lights tool Similarly the Sequence Inputs tool displays the hard wired signals statuses With the machine in manual mode cycle the machi...

Страница 18: ...Lynx Shielded Sequence Module ID7 M SEQ Product Manual 12 RJG Inc...

Страница 19: ...d the eDART sequencer can adjust for some of these abnormalities For example if the screw run signal is available it will reject additional injection forward on signals until after the screw stops Wit...

Страница 20: ...Mold clamped plus a set time to turn on and a set injection forward on time detected by eDART 2 No mold closed clamped signal If no mold closed clamped signal is available but both mold opening and m...

Страница 21: ...uence Module ID7 M SEQ RJG Inc 15 CUSTOMER SUPPORT Contact RJG s Customer Support team by phone or email RJG Inc Customer Support P 800 472 0566 Toll Free P 1 231 933 8170 email CustomerSupportGroup r...

Страница 22: ...Lynx Shielded Sequence Module ID7 M SEQ Product Manual 16 RJG Inc...

Страница 23: ...ID7 M 3M provides a connection from molding machines sequence output card and the RJG Inc ID7 M SEQ 1 2 3 LYNX CABLES CE LX5 The Lynx sensor cable 2 at right is a polypropylene coated cable suited fo...

Страница 24: ...panels LYNX SHIELDED DUAL RELAY OUTPUT MODULE OR2 M The Lynx shielded dual relay output module OR2 M 2 at right is a shielded DIN rail mounted module that interfaces the eDART and sorting equipment or...

Страница 25: ......

Страница 26: ...E A PTE LTD Singapore Republic of Singapore P 65 6846 1518 sales swg rjginc com en rjginc com FRANCE RJG FRANCE Arnithod France P 33 384 442 992 sales fr rjginc com fr rjginc com CHINA RJG CHINA Chen...

Отзывы: