Rev 2-17
A5089K
O-RING INSTALLATION & MATERIAL INFORMATION
All RIX part numbers for o-rings begin with a 123 prefix. This is followed by a second set
of 3 digits which corresponds to US Standard
AS568
sizing.
RIX normally uses a
Viton
70 durometer
o-ring, in which case the part number will have a
“-5” suffix, such as 123-040-5. In many cases a
90 durometer
is used, which is indicated
by an additional “-90” at the end of the part number, such as
123-040-5-90.
Viton is
required for oxygen or high temperature service, and 90 durometer is often required in high
temp/ high pressure locations. For materials other than Viton a different suffix is used (see
chart below).
CAUTION:
All o-rings
used in
O2 service
must be
Viton or Teflon
. Buna o-rings are not
oxygen compatible and will sustain combustion, creating a high potential for explosion.
All o-rings, except for those located behind piston rings, should be lubricated with an
appropriate high temperature grease such as
Krytox
or
Christo-Lube
MGC-111
before
installation. Apply a thin coating by drawing the o-ring through your fingers. This will
extend the life of the seal and simplify installation.
CAUTION:
O-rings used in oxygen service must be lubed with an
oxygen compatible
grease (RIX P/N 45-1007, 45-19220 or equivalent).
All o-rings supplied for
O2
service
have an
X prefix
, and are oxygen cleaned and bagged to
maintain cleanliness. Never use a non-O2
cleaned part for oxygen service.
Standard o-rings available from hardware stores, etc. are usually Buna type and will fail
when used in high temperature or oxygen applications.
O-RING & BACK-UP RING MATERIALS
RIX PART NO.
MATERIAL
O-rings
123-XXX-2, -2S
Silicone
123-XXX-3
Teflon
123-XXX-5
Viton
123-XXX-7
Kel-F
123-XXX-9
Kal-Rez, Compound 2037
123-XXX-10
Viton with FDA approval
123-XXX-11
Viton V1289-75, Low temp (-50°F)
123-XXX-12
Parafluor Ultra, FF102-75
X123-XXX-5
Viton (
O
XYGEN
C
LEANED
)
Back-up Rings
124-XXX-3
Teflon (split)
124-XXX-8
Teflon (solid)
Note:
Some –7 o-rings are metal and some –9's are metallic C-rings. But these
P/N's take the form 123-XXXX-7 and –9 (
FOUR
X'
S
)
CUI//SP-CTI/PROPIN
Содержание 2PS-H-N2
Страница 36: ...RIX Industries MAN 2PS2B N2 Page 28 FIGURE 1 COMPRESSOR CROSS SECTION FASTENER DETAIL...
Страница 37: ...RIX Industries MAN 2PS2B N2 Page 29 FIGURE 2 COMPRESSOR CROSS SECTION PUMP DETAIL...
Страница 38: ...RIX Industries MAN 2PS2B N2 Page 30 FIGURE 3 1ST STAGE VALVE DETAIL...
Страница 39: ...RIX Industries MAN 2PS2B N2 Page 31 FIGURE 4 2ND STAGE VALVE DETAIL...
Страница 40: ...RIX Industries MAN 2PS2B N2 Page 32 FIGURE 5 EXTERIOR FASTENER DETAIL...
Страница 41: ...RIX Industries MAN 2PS2B N2 Page 33 FIGURE 6 MOTOR AND CONTROL BOX MOUNTING...
Страница 42: ...RIX Industries MAN 2PS2B N2 Page 34 FIGURE 7 SUCTION PLUMBING DETAIL...
Страница 43: ...RIX Industries MAN 2PS2B N2 Page 35 FIGURE 8 INTERSTAGE PLUMBING DETAIL...
Страница 44: ...RIX Industries MAN 2PS2B N2 Page 36 FIGURE 9 FINAL DISCHARGE PLUMBING DETAIL...
Страница 45: ...RIX Industries MAN 2PS2B N2 Page 37 FIGURE 10 COOLING FAN SUB ASSEMBLY DETAIL...
Страница 46: ...RIX Industries MAN 2PS2B N2 Page 38 FIGURE 11 BELT INSTALLATION DETAIL...
Страница 47: ...RIX Industries MAN 2PS2B N2 Page 39 FIGURE 12 GUARD MOUNTING DETAIL...
Страница 48: ...RIX Industries MAN 2PS2B N2 Page 40 FIGURE 13 CONTROL BOX DETAIL 1 OF 2...
Страница 49: ...RIX Industries MAN 2PS2B N2 Page 41 FIGURE 14 CONTROL BOX DETAIL 2 OF 2...
Страница 50: ...RIX Industries MAN 2PS2B N2 Page 42 FIGURE 15 CONTROL BOX WIRING DIAGRAM...
Страница 51: ...RIX Industries MAN 2PS2B N2 Page 43 FIGURE 16 ELECTRICAL SCHEMATIC...
Страница 52: ...RIX Industries MAN 2PS2B N2 Page 44 FIGURE 17 FLOW SCHEMATIC...
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 59: ......