18
www.rivatech.de
Camera ID Setup
ID number of camera is set using binary number. The example is shown bellow.
DIP1
Pin
1
2
3
4
5
6
7
8
ID Value
1
2
4
8
16
32
64
128
Default
on
off
off
off
off
off
off
off
ex) ID=10
off
on
off
on
off
off
off
off
The range of ID is 1~255. Do not use 0 as camera ID. Factory default of Camera ID is
1.
If you want to control a certain camera, you must match the camera ID with Cam ID
setting of DVR or Controller.
Communication Protocol Setup
Select the appropriate Protocol with DIP switch combination.
DIP2
Pin
1
2
3
4
5
6
7
8
ID
Value
RS485
Terminatio
n
Not
used
Protocol
1
Protocol
2
Not
used
Not
used
Baud Rate
1
Baud Rate
2
Default
Off
Off
Off
Off
Off
Off
Off
On
Pin1 is used for RS485, 100W termination. Set ON DIP2-1st of only the last looped
camera from the controller. Even in case of only one camera, set ON DIP2-1st of the
camera.
1
2
3
4
5
6
ON
ON
7
8
TERMINATION
SW1-ON
CAM 1
CAM 2
CAM n-1
CAM n