GB
INFRARED MOTION SENSOR
Welcome to use 28512 0 Infrared motion sensor!
The product adopts good sensitivity detector and integrated circuit. It gathers automatism, convenience, safety,
saving-energy and practical functions. It utilizes the infrared energy from human as control-signal source and it can
start the load at once when one enters detection field. It can identify day and night automatically. It is easy to install
and used widely.
SPECIFICATION
• Power Source: 220-240V/AC
• Detection Range: 120°/360°
• Power Frequency: 50Hz
• Detection Distance: 3m/6m (choice) (<24°C)
• Ambient Light: 10LUX/2000LUX (choice) • Working Temperature: -20~+40°C
• Time Delay: 5s, 30s, 1min, 3min
• Working Humidity: <93%RH
5min, 8min (choice)
• Power Consumption: approx 0.5W
• Rated Load: Max. 800W
• Installation Height: 1.8-2.5m (wall mounting)
Max. 300W
• Installation Height: 2.2-4m (ceiling mounting)
• Detection Moving Speed: 0.6-1.5m/s
FUNCTION
• Can identify day and night automatically: when turn to SUN ((below is SUN)), it will work day and night, when
turn it to MOON (above is moon), it will only work in the ambient light less than 10LUX. As for adjustment, please
refer to testing way.
• SENS adjustable: It can be adjusted according to using location. The detection distance of low sensitivity could be
only 3m and high sensitivity could be 6m which fits for large room.
• Time-Delay is added continually: When it receives the second induction signals within the first induction, it will
restart to time from the moment.
Good sensitivity
Poor sensitivity
INSTALLATION ADVICE
As the detector responds to changes in temperature, avoid the following situations:
• Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc.
• Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, light etc.
• Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc.
CONNECTION
Warning. Danger of death through electric shock!
Must be installed by professional electrician.
Disconnect power source.
Cover or shied any adjacent live components.
Ensure device cannot be switched on.
Check power supply is disconnected.
• Connect the power and the load according to the connection-wire diagram.
• Fix the bottom on the selected position with the inflated screw.
• Switch on the power and test it.
ANL_28512 0.indd 5
2016/2/24 17:41:52