background image

2 Documentation Notes 

 

 

 

CMC-TC Wireless I/O-Unit 

4

EN

Documentation Notes 

The audience for this guide is the technical special-
ists familiar with the assembly, installation and op-
eration of the CMC-TC Wireless I/O-Unit. 

• 

You should read this operating guide prior to the 
commissioning and store the guide so it is readily 
accessible for subsequent use.  

Rittal cannot accept any liability for damage and 
operational malfunctions that result from the non-
observance of this guide. 

2.1  Associated Documents 

The guides for other CMC-TC components and their 
safety notes also apply together with this guide. 

This guide can also be downloaded from 
www.rimatrix5.com in the Internet and is also pre-
sent as file on the CD-ROM of the Processing Unit 
II: 

German: 7320240VXXd.pdf 

English: 7320240VXXe.pdf 

To view the guide you require the Acrobat Reader 
program; Acrobat Reader can be downloaded from 
www.adobe.com 

2.2  Retention of the Documents 

This guide and all associated documents are part of 
the product. They must be given to the operator of 
the unit and must be stored so they are available 
when needed. 

2.3  Used Symbols 

The following safety and other notes are used in this 
guide: 

Symbol for a handling instruction: 

• 

This bullet point indicates that you should perform 
an action. 

Safety and other notes: 

 

Danger! 
Immediate danger to health and life! 

 

 

Warning! 
Possible danger for the product and 
the environment! 

 

 

Note!

 

Useful information and special features. 

 

Safety Notes 

Observe the subsequent general safety notes for 
the installation and operation of the unit: 

− 

Assembly and installation of the CMC-TC Wire-
less I/O-Unit, in particular for wiring the enclo-
sures with mains power, may be performed only 
by a trained electrician. Other tasks associated 
with the CMC-TC Wireless I/O-Unit, such as the 
assembly and installation of system components 
with tested standard connectors, and the opera-
tion and configuration of the CMC-TC Wireless 
I/O-Unit may be performed only by instructed 
personnel. 

− 

Observe the valid regulations for the electrical 
installation for the country in which the unit is in-
stalled and operated, and the national regulations 
for accident prevention. Also observe any com-
pany-internal regulations (work, operating and 
safety regulations). 

− 

Prior to working at the CMC-TC system, it must 
be disconnected from the power supply and pro-
tected against being switched on again. 

− 

Use only genuine or recommended parts and 
accessories (see Section 4.5 Accessories). The 
use of other parts can void the liability for any re-
sulting consequences. 

− 

Do not make any changes to the CMC-TC Wire-
less I/O-Unit that are not described in this guide 
or in the associated guides. 

− 

The operational safety of the unit is guaranteed 
only for its approved use. The limit values stated 
in the technical specifications (see Section 14 
Technical Specifications) may not be exceeded 
under any circumstances. In particular, this ap-
plies to the permitted ambient temperature range 
and to the permitted IP protection category. When 
used with a higher required IP protection cate-
gory, the Rittal CMC-TC must be installed in a 
housing or enclosure with a higher IP protection 
category. 

− 

The operation of the CMC-TC system in direct 
contact with water, aggressive materials or in-
flammable gases and vapours is prohibited. 

− 

In addition to these general safety notes, also 
observe any special safety notes listed for the 
specific tasks in the individual sections. 

 

Содержание DK 7320.240

Страница 1: ...EN CMC TC Wireless I O Unit DK 7320 240 Assembly Installation and Operation A38148 11 IT 74 ...

Страница 2: ...H 45504 Telefon 1 937 399 05 00 Fax 1 937 390 55 99 eMail rittal rittal corp com Website www rittal corp com Published 03 11 2008 Microsoft Windows is a registered trademark of Microsoft Corporation Acrobat Reader is a registered trademark of Adobe Systems Incorporated ...

Страница 3: ...mming Mode 11 7 5 Tips and Notes for the Sensor Placement 11 7 5 1 Tips for the Calibration of the Sensor Locations 11 7 5 2 Introduction to the Wireless Data Transmission for the Rittal Wireless Sensor Network 12 7 5 3 Wireless System Range Estimate 13 7 5 4 Troubleshooting 14 8 Operation 15 8 1 Access Using a Browser 15 8 1 1 Login Using a Browser 15 8 1 2 Main Page View 15 8 1 3 General Overvie...

Страница 4: ...t in particular for wiring the enclo sures with mains power may be performed only by a trained electrician Other tasks associated with the CMC TC Wireless I O Unit such as the assembly and installation of system components with tested standard connectors and the opera tion and configuration of the CMC TC Wireless I O Unit may be performed only by instructed personnel Observe the valid regulations ...

Страница 5: ...ation change Flashing red System is in reset 3 Wireless connection LED Off No operating voltage is present Green Normal operation Green interrupted briefly for some time ms a data package is being sent Orange System is in repeater mode Red System in repeater mode has lost the base station Flashing red System is in reset Flashing green orange red System is in the log in mode 1 2 3 Fig 2 CMC TC Wire...

Страница 6: ...or Country version USA CDN UL approval FT1 VW1 1 7200 214 Connec tion cable for power pack Extension cable IEC connector and socket 1 Yes once for power pack 7200 215 1 U mounting unit 1 7320 440 Assem bly 1 U single moun ting unit with strain relief 1 Optional 7320 450 RJ45 0 5 m 7320 470 RJ45 2 0 m 7320 472 Connec tion cable RJ45 5 0 m 1 1 7320 475 Tab 3 Required accessories 4 5 2Optional Access...

Страница 7: ...te of the mounting module Ensure that the retaining plate sits between the guide rails of the CMC TC Wireless I O Unit Fig 4 Assembly with Velcro fasteners Take the self adhesive Velcro fasteners from the supplied accessories and remove the protective foil from the Velcro fasteners Ensure that the adhesion surfaces are free from grease and dust Attach the Velcro fasteners to the housing of the CMC...

Страница 8: ...tion 4 5 1 Required Accessories Insert the plug connector of the RJ45 connection cable in the socket as shown above of the CMC TC Wireless I O Unit Power 24 VDC max 2 5 A I0I0I 1 P I C 2 1 2 4 3 1 Fig 7 Connecting to the CMC TC Processing Unit with software version as of V 2 46 Key 1 CMC TC units connection Insert the other end of the RJ45 connection cable in a free RJ45 socket with number 1 to 4 ...

Страница 9: ...de one second The Status LED on the sensor illuminates once briefly If the registration process was successful the Wireless Connection LED of the CMC TC Wireless I O Unit flashes green for approximately two seconds then alternately red yellow green Simultaneously the Status LED on the CMC TC Wireless I O Unit flashes alternately red yellow and green Note During the registration process the dis tan...

Страница 10: ...ve seconds until the Status LED flashes very quickly To perform an immediate removal switch off the sensor as described above On the configuration page in your web browser switch to the sensor configuration To do this click first in the main overview on the sensor island I O Unit to which the sensor to be removed is connected Fig 15 You must be logged in as administrator to use this function 1 Fig...

Страница 11: ...h sensor location must be tested in advance using the wireless meas uring system sensor DK 7320 242 Procedure i Place the I O Unit into operation at the planned location as described in Section 7 1 Tip Before starting the calibration succes sively connect all sensors to the I O Unit This causes the sensors to be placed in front of the measuring system sensor in the registration list of the Process...

Страница 12: ...propriate for light If you follow this model it becomes clear that a di rect line of sight connection between the base and the sensor is the most favourable installation vari ant Walls furnishings etc in the vicinity can how ever act as a mirror that reflects the signal like light In this case not only the original signal but also reflected signals from various directions arrive at the receiving p...

Страница 13: ...se values are highly dependent on the ambient reflection Enclosure suite for steel door closed up to 6m for steel door 70 vented up to 20m for glazed door up to 30m Enclosure suite side for steel door closed up to 6m for steel door 70 vented up to 10 m for glazed door up to 10 m Note These values are highly dependent on the ambient reflection Adjoining room masonry thickness 30 cm concrete for ste...

Страница 14: ...ter present Test the wireless link using the wireless meas uring system Display value should be 8 9 in the vicinity of the I O Unit If necessary rectify the interfering transmitter Sensor is sometimes not received Sensor lies in the fringe range of the I O Unit Test the wireless link using the wireless meas uring system If the display value is smaller than 8 change the installation location or use...

Страница 15: ...utton To clear the input click the Clear button 8 1 2Main Page View 1 2 3 4 5 6 7 8 9 Fig 22 Main page overview Key 1 Address bar 2 Status window 3 IP address of the Processing Unit 4 Link to the main page view 5 Setup link 6 Log link 7 Administration link 8 User name 9 User logout 8 1 3General Overview Status Win dow 1 2 4 3 5 6 Fig 23 I O Units overview Key 1 Connection number and type of the I ...

Страница 16: ...uler 7 Enter here the numbers 1 to 4 of the mobile wire less numbers that should receive an SMS when an alarm is issued To create the mobile wireless numbers please consult the operating manual of the CMC TC Processing Unit The numbers must be entered separated by an character e g 1 2 3 4 8 Enter here the numbers 1 to 4 of the email adress that should receive an email when an alarm is is sued To c...

Страница 17: ...has al ready been registered at a different I O Unit you have to reset the repeater first To reset please press c key for 10 seconds until the status LED is flashing Press for two seconds the C key on the Wireless I O Unit master The wireless connection LED flashes red yellow and green You are now in programming mode Now go to the Repeater Wireless I O Unit and press once the C key You now receive...

Страница 18: ... I O Unit as Repeater Hoplist example Fig 30 Hoplist example repeater The humidity sensor was registered on tab 2 The removed CMC TC Wireless I O Unit repeater on tab 3 You see the following message in the hop list Fig 31 Hoplist repeater This means that the signals of the CMC TC wire less humidity sensor on tab 2 using the CMC TC Wireless I O Unit repeater on tab 3 go to the CMC TC Wireless I O U...

Страница 19: ...r product spectrum contact the following service address Tel 49 0 2772 505 1855 http www rimatrix5 com E mail info rittal de Note To allow us to process your enquiry quickly and correctly please always specify the article number in the subject line for e mails Further information and the current operating manuals and updates of the Rittal CMC TC can be downloaded from http www rimatrix5 de s ervic...

Страница 20: ...MCBASE0108V2 Statement according to FCC part 15 21 Modifications not expressly approved by this company could void the user s authority to oper ate the equipment Statement according to FCC part 15 105 Note This equipment has been tested and found to comply with the limits for a Class A digital de vice pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protec tion ...

Отзывы: