Section 5
Specifications
28
Methods for Connecting the Relay Switch to a Strobe Light
1. A simple switch closure capable of handling 3A current.
Any strobe light used would require external power, either AC or DC.
60201127
Description
Strobe Light
Blue
Normally Open Switch Contact
On/Off Switch
Green
Common Switch Contact
On/Off Switch
White
+10.5V, 400mA MAX
No Connection
Brown
Ground
No Connection
2. Using the switch to connect 10.5 VDC from the Loudmouth
®
.
This allows a strobe light to be DC powered by the Loudmouth
®
when the relay is closed.
60201127
Description
Strobe Light
Blue
Normally Open Switch Contact
Power Supply (+)
Green
Common Switch Contact
Connect to White wire
White
+10.5V, 400mA MAX
Connect to Green wire
Brown
Ground
Power Supply (-)
3. A switch closure to ground to activate.
Any strobe light used would require external power, either AC or DC.
60201127
Description
Strobe Light
Blue
Normally Open Switch Contact
On/Off Switch
Green
Common Switch Contact
Connect to Brown wire
White
+10.5V, 400mA MAX
No Connection
Brown
Ground
Connect to Green wire
4.10
Radio Operation Timeline
(serial number A100119000 or higher)
The following timeline explains operation for radios with serial number A100119000 or higher. In this example the Loudmouth
®
is programmed for:
Record and Play
Record and Play Delay of 10 seconds
Record and Play Repeat 3 times
Relay Operation Enabled
Pre-Announce Tone Enabled
On/Off Switch
On/Off Switch
Power Supply (+)
Power Supply (-)
Power Supply (+)
Power Supply (-)
On/Off Switch
Power Supply (+)
Power Supply (-)
Loudmouth
®
receives
a valid receive signal
Received message
is recorded
10 second
delay
Pre-Announce
Tone plays
Recorded Message
plays
Recorded Message
replays 3 times
Relay is closed for strobe light operation