background image

 

 

Green

Red

Got the answer

Send test message

 

8.9.

 

If an additional alarm wire loop is used, insert the ribbon cable and connect it to 
the XT1. 

8.10.

 

Put corresponding wires in slots and secure the enclosure base on the surface. 
An enclosure tear-off tamper is installed by default. 

8.11.

 

Switch the device to the standby mode (see Paragraph 5). 

8.12.

 

Verify the signal path for alarm signals of the sensor, tamper, and, if necessary, 
additional alarm wire loop by referring to LED indicators. 

8.13.

 

Install the mating piece (magnet) not further than 10 mm away from the SA1 reed 
relay. If necessary, use backing plates. 

8.14.

 

 The device is ready for operation. 

 
 
 
 
 

9.

 

Hardware Reset to Factory Settings 

Remove the battery from its holder, install the JMP1+JMP3 jumpers, and place the 

battery back. This procedure is shown in the diagram: 

t

5 times

The device reset settings

Red

The settings have been reset

to factory settings

 

The radio signal strength between the device and the control panel is 
determined by the level of signal attenuation, which can be seen in the radio 
channel security and control panel configuration software, page Radio Device 
Map. For more information please refer to the control panel user manual. 

Содержание RDD2

Страница 1: ...Magnetic wireless sensor RDD2 Data sheet Device identification number ...

Страница 2: ...mits them to the control panel 2 Manufacturer 195248 Energetikov avenue building 30 block 8 St Petersburg Russia Tel 7 911 795 02 02 3 Package Contents Magnetic wireless sensor RDD2 1 pc N35 6 25 magnet in enclosure 1 pc Magnet backing plate 3 pcs 2 mm jumper 2 pcs Enclosure tear off tamper1 1 pc Enclosure break in tamper 1 pc АА ER14505 3 6В battery 1 pc Kit for fastening enclosure and magnet to ...

Страница 3: ...g period of device operation in radio system min 4 Enclosure break in tamper Yes Surface tear off tamper Yes Normal state setup for additional wire loop Yes Radio system configuration w o personal computer Yes Battery type 3 6 V Li battery Standalone operation time from one battery yrs up to 32 Dimensions mm 29 101 38 Weight g 63 Operating temperature range С 30 55 5 Arrangement of Elements on the...

Страница 4: ...ribed in Paragraphs 7 6 Designation of Jumpers To change a device s operating mode remove its battery install remove necessary jumpers and place the battery back respecting its polarity Installed Jumpers Operating Mode JMP1 Mode of addition to radio system JMP2 Not used JMP3 Radio channel test mode JMP1 JMP3 Configuration hardware reset mode All jumpers removed Operating mode 7 Visual Indication3 ...

Страница 5: ...enclosure 8 3 Install a battery and close the cover 8 4 After closing the device cover or installing the battery the device switches to battery test mode signaled by the red indicator turning on for 2 seconds If the battery had not been in use for a long time it depassivates The red indicator lights up in series of flashes illustrated in the figure below up until the moment the battery goes into t...

Страница 6: ... system instruction The distance between the device and the receiver should be at least 1 m The device then receives settings from the control panel The addition process is illustrated in the diagram t Device successfully added to radio system Adding to radio system is in progress Red The active device has been found Green The device switched to adding mode 8 7 Switch the device to the radio chann...

Страница 7: ... mating piece magnet not further than 10 mm away from the SA1 reed relay If necessary use backing plates 8 14 The device is ready for operation 9 Hardware Reset to Factory Settings Remove the battery from its holder install the JMP1 JMP3 jumpers and place the battery back This procedure is shown in the diagram t 5 times The device reset settings Red The settings have been reset to factory settings...

Страница 8: ... that the device complies to requirements of the technical specifications provided the client ensures compliances to conditions of transportation storage installation and operation Although the warranty period is 12 months from the commissioning date it may not exceed 18 months from the production date The warranty storage period is 6 months from the production date The warranty does not cover the...

Отзывы: