![ritm Contact GSM-14 Wi-Fi Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/ritm/contact-gsm-14-wi-fi/contact-gsm-14-wi-fi_datasheet_1464672005.webp)
5
№
Element
Designation
1 Fixing
holes
4 holes for fixing to surface
2
+12V, GND, SIREN
Terminals for connecting power supply and
wired siren:
+12V – power supply “plus” (if using
external power supply 12V);
GND – power supply “minus” (if using
external power supply 12V) and “minus” of
the siren;
SIREN – «plus» of the siren.
3 SA1
Tamper button
4
Connector for power adapter
Connect the power adapter (included in scope of
delivery)
5
JMP 1, 2, 3
Connectors for jumpers
6 SIM1
Main SIM-card
7 SIM2
Redundant SIM-card
8
Location for the battery
Connector for battery BL-5C connection
(included in scope of delivery)
9 Buzzer
Audible signals (see paragraph 6)
10 Button
When clicking an alarm event is generated
(see section 7)
11 Indicators
Light indication of the panel basic parameters
(see section 6)
6.
Indication
The device has 4 visual (blue) indicators at its front panel.
To turn on the visual indication and the audio signal (buzzer), configure their operating
modes in the configuration software. The following visual indication settings are available:
Device power supply status;
Availability of unsubmitted events;
Device registration in GSM network;
Status of sensors in one area.
Audio indication:
Successful registration in GSM network;
Incoming call;
Input delay;
Output delay;
Alarm in area;
7.
Panic button
Panic button. Creates an event that is recorded into the device history
and transmitted over configured data links. The event code is specified
in the configuration software. Inactive by default.