Section 4: SETTING UP THE RITE-POWER 615
Inspect the proposed area for use.
An inspection of the proposed area in which to set up the RITE-POWER 615 is necessary
to ensure it is suitable for safe operation. This inspection should be performed by the
operator prior to using the RITE-POWER 615.
The area should be free from moving vehicles, machinery, pedestrians or other factors
which may mean the RITE-POWER 615 could form a hazard.
Set the RITE-POWER 615 up in such a way that it cannot obstruct walkways or areas that
form emergency exit routes.
Do not leave unattended if there is potential for minors or non-competent persons to
tamper with the RITE-POWER 615 whilst in use.
PROTECTION SYSTEMS AND FAULT SIGNALLING
• Short Circuit Protection – The RITE-POWER 615 will shut down until the fault is
removed, It will signal this by flashing the red LED continuously and a beeper will
be heard.
• Overload Protection – The RITE-POWER 615 will shut down until the load is reduced.
It will however allow small overloads up to 120% for short periods of time up to a
minute. It will signal this by flashing the red LED continuously 5 times which will then
be repeated and a beeper will be heard until the fault condition is removed.
• Over Temperature Protection – The RITE-POWER 615 will shut down until it has
cooled sufficiently to allow it to function again. It will signal this by flashing the red
LED continuously 4 times which will then be repeated and a beeper will be heard until
the fault condition is removed.
• Low Battery Capacity – The RITE-POWER 615 will eventually shut down until the
battery has been recharged sufficiently. It will signal this by flashing the red LED
continuously and a beeper will be heard until the fault condition is removed.
• Low Battery Capacity Shut Off – The RITE-POWER 615 has shutdown due to
insufficient battery capacity.
It will signal this by flashing the red LED continuously twice which will then be
repeated and a beeper will be heard until the fault condition is removed.
• Over Voltage Protection – The RITE-POWER 615 will shutdown if the voltage from the
battery/charger rises above a particular threshold, if this happens this would suggest
a permanent fault in the charging system and the issue should be investigated by a
competent person – please contact Ritelite (Systems) Ltd or its authorised distributor.
It will signal this by flashing the red LED continuously 3 times which will then be
repeated and a beeper will be heard until the fault condition is removed.
• Note in most cases the inverter will automatically reset itself after a fault
condition has been removed, in some cases it may be necessary to switch off
then back on the power switch to reset the unit.