Publication:
AMEN00064 2019‑03‑07
9
Rite‑Hite
®
Installation/Service/Owner’s Manual
Revolution
®
HVLS Fan • Rogue
®
HVLS Fan
INSTALLATION
Step 3 – Motor Bracket
The motor bracket attaches to the extension tube with (2)
1/2in x 4‑1/2in Grade 8 bolts, washers, and locknuts
1 Position the motor bracket so that 1 angle is on each
side of the extension tube
2 Insert the bolts through the holes in the angles at the
top of the motor bracket and through the extension
tube and back through the second angle
3 Tighten both locknuts securely
When an extended down tube is used:
The smaller square tubing (3in x 3in [75mm x 75mm]) will
telescope inside the larger square tubing (35in x 35in
[90mm x 90mm]). The brackets on the top of the motor
bracket are bolted in slots to allow the larger tube to bolt
to the top of the motor. The 3in x 3in [75mm x 75mm] tube
should always bolt to the ceiling bracket
When fan assembly is mounted directly to the ceiling
bracket (without an extension tube):
Use (4) 1/2in x 1‑1/2in Grade 8 bolts (supplied by others)
to attach the ceiling bracket