2 Publication:

 AMEN00064 2019‑03‑07

Revolution

®

 HVLS Fan • Rogue

®

 HVLS Fan 

Installation/Service/Owner's Manual

 Rite‑Hite

®

NOTICE TO USER

READ AND SAVE THESE INSTRUCTIONS.

Thank you for purchasing a Rite‑Hite product 
The Revolution and Rogue Fans are high‑volume/low‑speed 

(HV/LS) industrial fans that provide more consistent air 

circulation and ventilation with better energy efficiency than 

traditional high-speed ceiling fans or industrial floor fans.

The English version of this manual shall prevail over any  

error in, or conflicting interpretation of, any translations.

Rite‑Hite reserves the right to substitute and/or modify 

parts and drawings (electrical and architectural) from 

those contained in this manual Separate prints may be 

included with the unit 
For best results, have this product serviced by an 

authorized Rite‑Hite representative
A Planned Maintenance Program (PMP), customized  

to your specific operation is available and recommended. 

For a PMP, contact your local Rite‑Hite representative  

or Rite‑Hite technical support at (US) 888‑456‑3625  

or 1‑414‑973‑3625, (SA) +55 21 99616 4421,  

(EU) +49‑5693 98700

The Rite‑Hite

®

 products in this manual are covered by one or more of 

the following US patents: 7658232, 8622712, 8142156, D631536, 

7726945 and may be covered by additional pending US and foreign 

patent applications

Manufactured by Rite‑Hite Engineered Solutions Group, Inc

FCC Compliance

NOTE:

This equipment has been tested and found to comply with the 

limits for a Class A digital device, pursuant to Part 15 of the FCC Rules 

These limits are designed to provide reasonable protection against 

harmful interference when the equipment is operated in a commercial 

environment This equipment generates, uses, and can radiate radio 

frequency energy and, if not installed and used in accordance with 

the instruction manual, may cause harmful interference to radio 

communications Operation of this equipment in a residential area 

is likely to cause harmful interference in which case the user will be 

required to correct the interference at his own expense

NOTE:

Changes or modifications not expressly approved by the party 

responsible for compliance could void the user's authority to operate the 

equipment
Contains FCC ID: MCQ‑XB900HP
Contains IC: 1846A‑XB900HP
This device complies with Part 15 of the FCC Rules  

Operation is subject to the following two conditions:
1  This device may not cause harmful interference
2  This device must accept any interference received, including 

interference that may cause undesirable operation

SAFETY 
Safety Identifications

!

 DANGER

Indicates a hazardous situation which, if not 

avoided, will result in death or serious injury.
Indique une situation dangereuse qui, si elle n’est 

pas évitée, peut entraîner la mort ou de graves 

blessures.

 WARNING / AVERTISSEMENT

Indicates a hazardous situation which, if not 

avoided, 

could result in death or serious injury

.

Indique une situation dangereuse qui, si elle n’est 

pas évitée, 

peut entraîner la mort ou des blessures 

graves

.

!

 CAUTION / ATTENTION

Indicates a hazardous situation which, if not 

avoided, 

could result in minor or moderate injury

.

Indique une situation dangereuse qui, si elle n’est 

pas évitée, 

peut entraîner des blessures légères à 

modérées

.

NOTICE

Indicates a situation which can cause damage to the 

equipment, personal property and/or the environment, 

or cause the equipment to operate improperly

NOTE:

A note is used to inform you of important 

installation, operation, or maintenance information

Содержание Revolution HVLS Fan

Страница 1: ...bilization Cables INCLUDED WITH KIT 11 Step 6 Attach Blades 11 Step 7 Level Hub 11 Step 8 Fan Electrical Installation TYPICAL 12 Step 9 Control Box 13 Step 10 Label Plate 13 Step 11 Motor Cover 13 Fan...

Страница 2: ...quipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause...

Страница 3: ...SI NFPA 70 1999 and local codes L installation doit tre effectu e conform ment au Code national de l lectricit la norme ANSI NFPA 70 1999 et aux codes locaux DANGER A qualified electrician should inst...

Страница 4: ...Drill and 1 2in drill bit If mounting to support angles that span building joists Specifications Diameter 8ft 12ft 16ft 20ft and 24ft 2440mm 3660mm 4880mm 6100mm and 7320mm Blades Aluminum Blade Finis...

Страница 5: ...Minimum Beam Kit Truss Kit Fan Drop Height 56 5in 1440mm Fan Drop Height 48 00in 1220mm Fan Standard Low Headroom Standard Low Headroom Standard Low Headroom 8ft 2440mm 34in 870mm 36in 920mm 25in 640...

Страница 6: ...beam for the hanger dimension If the roof is pitched this must be accounted for above the tips of the blades Fan Weight and Torque NOTICE The weight of the fan that will be suspended from the ceiling...

Страница 7: ...e du ventilateur et causer des blessures TYPICAL CEILING TRUSS MOUNTING OPTIONAL LAMINATED BEAM KIT OPTIONAL B B A C D A Angles Support 3in x 3in x 1 4in 75mm x 75mm x 7mm recommended B Building Joist...

Страница 8: ...BEAM KIT OPTIONAL 1 Through bolt the laminated beam brackets with 1 bracket on each side of the laminated or concrete beam Figure 4 2 Attach the standard ceiling mounting bracket to this bracket in t...

Страница 9: ...and through the extension tube and back through the second angle 3 Tighten both locknuts securely When an extended down tube is used The smaller square tubing 3in x 3in 75mm x 75mm will telescope ins...

Страница 10: ...t contre la chute d un ventilateur dans le cas d un rel chement de l assemblage boulonn A B C 1 Wrap a safety cable around the bolted brackets at the ceiling and through the top of the extension tube...

Страница 11: ...ecure the stabilization cables to the ceiling with 2 cable clamps and tighten with a turnbuckle 3 Cut stabilization cable to length as required 4 Ensure that stabilization cables are attached in a pos...

Страница 12: ...erminated at F1 F2 F3 Fuse Holder Incoming Power from End User Supplied Branch Circuit Fan Motor Disconnect Fan Control Box To Fan Motor Terminal Torque 20lb in Max ACCEPTABLE Unshielded Stranded Cond...

Страница 13: ...et so the slotted hole faces outward toward the fan blade c Repeat this process for the remaining 3 brackets 2 Attach the label plate to the label plate brackets a Insert the bolt up through the label...

Страница 14: ...r will receive three phase power from the fan control box even if single phase power is provided to the control box Remove the cover from the motor junction box Change the wire leads as necessary for...

Страница 15: ...ellow Motor conductors field terminated to VFD terminals using M4 fork connectors provided torque to 1 5Nm NOTE L3 wire and F3 fuse omitted for 230V single phase input option Motor conductors field te...

Страница 16: ...llation guidelines Ensure maximum physical separation between low voltage control cables and high voltage power cables minimum 150mm or 6in Ensure maximum physical separation between motor cable and a...

Страница 17: ...ck for fraying or wear Gear Reducer Check for oil leaks If leaks are present contact factory Check oil level Add oil if necessary oil type is marked on the gear case Motor Check for dust and dirt Remo...

Страница 18: ...fan motor cable from u v w and ground terminals GND 2 Using electrical meter measure resistance ohms between phase wand Phase V Record the 6 resistance values Phase W to V Phase W to GND Phase W to U...

Страница 19: ...Publication AMEN00064 2019 03 07 19 Rite Hite Installation Service Owner s Manual Revolution HVLS Fan Rogue HVLS Fan...

Страница 20: ...ZNC 12 4 NUT HEX NYL LOCK 1 2 13 GR8 Z 13 2 CABLE AIRCRAFT GLV 1 4 84 14 4 CLAMP CABLE ZINC 1 4 SNGL SAD 6 7 8 9 11 12 10 13 14 TRUSS KIT 55290016 MOUNT ASSY TRUSS FAN GY ITEM QTY DESCRIPTION 6 2 BRK...

Страница 21: ...84 9 2 CLAMP CABLE ZINC 1 4 SNGL SAD ITEM 18 30 84 120 DESCRIPTION 1 1 EXTN ASSY FAN 18 GY 2 1 EXTN ASSY FAN 30 GY 3 1 EXTN ASSY FAN 84 GY 4 1 EXTN ASSY FAN 240 GY 5 4 CABLE AIRCRAFT GLV 1 4 120 OR 4...

Страница 22: ...SNGL REV 8 DIA LHR 12510057 BLADE SNGL REV 12 DIA LHR 12510058 BLADE SNGL REV 16 DIA LHR 12510059 BLADE SNGL REV 20 DIA LHR 12510060 BLADE SNGL REV 24 DIA LHR DESCRIPTION PART STANDARD HEADROOM BLADE...

Страница 23: ...00026 or Filter EMC YSKW 240V 1PH 20A 45500023 2 INV YSKW 240V 3PH 10A 53300081 or INV YSKW 480V 3PH 05A 53300082 or INV YSKW 480V 1PH 10A 53300080 3 PCB RADIO 900MHZ VFD 16650014 or PCB RADIO 2 4MHZ...

Страница 24: ...ner s premises for the purpose of repairing or replacing the Product or y return of the Product to the Rite Hite F O B Rite Hite s factory NOT WARRANTED Rite Hite does not warrant against and is not r...

Отзывы: