TROUBLESHOOTING
Diagnostics Mode
Diagnostic mode may be entered while restraint is in any
state To enter diagnostic mode:
1 Press and hold DIAGNOSTIC button until horn chirps
(≈ 5 seconds).
2 Press LOCK button
3 Press UNLOCK button
4 Horn chirps and outside light is flashing RED
Controls are in first step of diagnostic mode
NOTE:
Outside red light will remain flashing at all
times except Step 10 (Diagnostic Sequence)
5 Start at Step 1 (Diagnostic Sequence)
If no buttons are pressed within a 5 minute period, controls
will automatically exit to power up To exit diagnostic mode
at any time, press DIAGNOSTIC button
Diagnostic Sequence
Press LOCK to advance,
UNLOCK to reverse
C = Horn Chirp
F = Off
P = Pulsing / Flashing
T = Steady On
OUTPUTS*
BASE MICRO CONTROLLER BOARD
POWER BOARD
12VDC
RELAY
115/230VAC
Inside red light [ISR]
Inside red light [ISR]
Corner-V
u red light [CVU RD]
Corner-V
u green light [CVU GRN]
Leveler-V
u red light [L
VU RD]
Leveler-V
u green light [L-VU GRN]
Pedestrian-V
u light [PVU L
T]
Approach-V
u light [A
VU L
T]
Outside red light [OSR]
Outside green light [OSG]
Dok-lok horn [HORN]
MWL
actuator [MWLACTR]
Outside alarm [MWL
ALM]
Unidox ITC [UD ITC OUT]
Green light interlock [GL
T ITL]
Green light interlock [GL
T ITL]
K2 - security system interface or
combined power unit [if equipped]
Motor ouptut #1 [M1/LOCK]
Motor ouptut #2 [M2/UNLOCK]
12VDC power supply ok
TERMINAL BLOCK NO.
J716 J717 J121 J122 J123 J124 J126 J125 J112 J111 J719 J152 J153 J154 J155 J93 J103 J54 J53 J21-6
POWER BOARD LEDS
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
LD2 LD1
LD7
MICRO CONTROL BOARD LEDS
LD17 LD19 LD11 LD13 LD18 LD12 LD16 LD14 LD49 LD48 LD15 LD37 LD40 LD20 LD39 LD9 LD10 LD1 LD3
-
STEP
1 Diagnostics entered
F
F
F
F
F
F
F
F
P
F
C
F
F
F
F
F
F
F
F
T
2
Check
Inside red
T
F
F
F
F
F
F
F
P
F
F
F
F
F
F
F
F
F
F
T
3
Inside green
F
T
F
F
F
F
F
F
P
F
F
F
F
F
F
F
F
F
F
T
4
Corner-Vu red
F
F
T
F
F
F
F
F
P
F
F
F
F
F
F
F
F
F
F
T
5
Corner-Vu green
F
F
F
T
F
F
F
F
P
F
F
F
F
F
F
F
F
F
F
T
6
Leveler-Vu red
F
F
F
F
T
F
F
F
P
F
F
F
F
F
F
F
F
F
F
T
7
Leveler-Vu green
F
F
F
F
F
T
F
F
P
F
F
F
F
F
F
F
F
F
F
T
8
Pedestrian-Vu light
F
F
F
F
F
F
T
F
P
F
F
F
F
F
F
F
F
F
F
T
9
Approach-Vu light
F
F
F
F
F
F
F
T
P
F
F
F
F
F
F
F
F
F
F
T
10
Outside red light
F
F
F
F
F
F
F
F
T
F
F
F
F
F
F
F
F
F
F
T
11
Outside green light
F
F
F
F
F
F
F
F
P
T
F
F
F
F
F
F
F
F
F
T
12
Dok-Lok horn
F
F
F
F
F
F
F
F
P
F
T
F
T
F
F
F
F
F
F
T
13
MWL actuator, Unidox outputs
F
F
F
F
F
F
F
F
P
F
F
T
F
T
F
F
F
F
F
T
14
Green light interlock outputs
F
F
F
F
F
F
F
F
P
F
F
F
F
F
T
T
F
F
F
T
15
K2 relay
F
F
F
F
F
F
F
F
P
F
F
F
F
F
F
F
T
F
F
T
16 Horn chirps = end of sequence
F
F
F
F
F
F
F
F
P
F
C
F
F
F
F
F
F
F
F
T
*IF OUTPUT DOESN’T MATCH:
2-3, 12
Check
Control harness connection at chevron and micro controller boards
Power supply LED and power supply fuse
on power circuit board
3-11
Light bulb, wiring and terminal block connections
13-15
Terminal block connections