SHR-5000™ Dok-Lok
®
Owner's Manual
Rite-Hite
®
26 Publication:
AMEN00096 2018-05-30
TROUBLESHOOTING
LED Status Chart
? = Varies (per operation)
* = On for 15 sec before M2 energizes
A = Alternating
D = Double fast pulsing / flashing
F = Off
ITL = Interlock input on
K = Continuous slow chirp
M = Lights when button pressed
P = Pulsing / Flashing
(set to steady using DIP switches)
T = Steady On
MICRO CONTROL BOARD
POWER BOARD
INPUTS
OUTPUTS
FIELD
PUSH BUTTONS 12VDC
RELAY
115/230VAC
Dok-Lok Limit Switch 1 [SW1]
Dok-Lok Limit Switch 2 [SW2]
Unlock Interlock [UNLK ITL]
Lock
Unlock
Horn Silence (1/2/3)
Inside Red Light [ISR]
Inside Green Light [ISG]
Corner-V
u Red Light [CVU RD]
Corner-V
u Green Light [CVU GRN]
Leveler-V
u Red Light [L
VU RD]
Leveler-V
u Green Light [L-VU GRN]
Outside Red Light [OSR]
Outside Green Light [OSG]
Dok-Lok Horn [HORN]
Restraint Overload LED [YELLOW]
K1 - Green Light Interlock
K2 - Security System Interface
[IF EQUIPPED]
Motor Ouptut #1 [M1/LOCK]
Motor Ouptut #2 (M2/UNLOCK)
12VDC Power Supply OK
TERMINAL BLOCK NO.
J131 J132 J143
Membrane
J716 J717 J121 J122 J123 J124 J112 J111 J719 N/A J93 J103 J54 J53 J21-6
POWER BOARD LEDS
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
LD2 LD1
LD7
MICRO CONTROL BOARD LEDS
LD20 LD23 LD30
LD52
LD17 LD19 LD11 LD13 LD18 LD12 LD49 LD48 LD15 LD50 LD9 LD10 LD1 LD3
–
NO.
010100
State/Sequence No
Locked State
F
T
?
–
–
–
F
P
F
P
F
P
P
F
F
F
T
T
F
F
T
010101
Locking Sequence
T
T
?
M
–
–
T
F
P
F
P
F
P
F
F
F
F
T
T
F
T
010200
Unlocked State
T
F
?
–
–
–
P
F
P
F
P
F
F
P
F
F
F
T
F
F
T
010201
Unlocking Sequence
T
T
ITL
–
M
–
T
F
P
F
P
F
P
F
F
F
F
T
*
T
T
010400
Fault State
T
T
?
–
–
–
P
F
P
F
P
F
P
F
P
F
F
F
F
F
T
010401
Fault Silenced State
T
T
?
–
–
M
A
A
A
P
F
F
F
T
T
F
F
T
010500
L/S Fault State Lock
F
F
?
–
–
–
D
F
D
F
D
F
P
F
D
F
F
F
F
F
T
011100
Overload Fault State
?
?
?
–
–
–
P
F
P
F
P
F
P
F
K
T
F
F
F
F
T
RESET PROCEDURE:
Motor Overload Fault State (Amber LED LD50 is illuminated and the Dok-Lok horn is slowly chirping)
1
Press and hold Horn Silence Button (3-Button System)/Horn Silence #2 Button (5-Button System) until Horn Chirps (≈ 5 Seconds). Or
2 Press and Release Restraint O/L Button on Micro Controller Board
When the motor overload has been reset, the Yellow LD50 LED will turn off and normal operation resumes If Dok-Lok motor does not run after resetting the overload, check Motor Fuse 10FU1