D. 

 

Electrical Connection

 

(Optional)  – 

In many areas, supplemental heat is required, it is easiest to run the 

electrical line at the same time you lay the waterline for your fountain.  Electrical connections should be installed 

under the unit.  

WARNING:  ANY ELECTRICAL SERVICE MUST BE INSTALLED AND MAINTAINED BY A 

QUALIFIED ELECTRICIAN.

  

E. 

 

Mounting Platform – 

A concrete platform should be provided for all fountains. It should be at least 4” thick 

and large enough to accommodate fountain. An additional 4” high step 18” out from each side of the unit will 

protect the unit from manure handling equipment, as well as discouraging animals from defecating in the 

fountain. Extending the platform provides animals a place to stand while drinking, consider the size of your 

animals when determining the dimensions of your platform. Slope the platform away from the fountain for 

drainage. A rough broom finish on the concrete surface provides better footing for animals.  

F. 

 

Preparing the Bottom - 

Apply the foam weather stripping to 

the bottom of the unit, along the outside edge of the fountain.   

G. 

 

Hold-Downs

  -  The 100, 150, 150S, and 300 fountains are 

provided with four built-in hold-downs, and the 1000 fountain is 

provided with six built-in hold-downs to anchor your unit securely to 

the platform. Use of 3/8” x 5” stainless steel expansion anchor bolts 

(not included) are  recommended for concrete installations. Anchor 

bolts are available from Ritchie in a two pack, part # 16555. Fender 

washers are supplied for use with anchors.  

H. 

 

Assemble Valve - 

The 100, 150, and 150S fountains come 

with the valve already assembled and ready for use. Skip to the next 

step for those units.

 

1.

 

Insert valve rubber into the valve rubber retainer.  

2.

 

Attach float arm to float as shown in diagram.  The 

raised emboss on top of float should be orientated as 

shown. 

3.

 

Screw thumb screw into cam arm.  To adjust water 

level, tighten thumb screw to lower, loosen thumb 

screw to raise. 

4.

 

Insert the valve rubber retainer into the valve body 

with the valve rubber up. Align the cam arm to the 

valve body and insert first pin. 

5.

 

Align the float arm and attached float to the cam arm 

and insert second pin. 

 

 

 

Valve Rubber 

WaterMatic Series Instruction Manual

2

August 13, 2022

Содержание WaterMatic 100

Страница 1: ...ring fountain on the market This unit is built to give you excellent service when properly installed and maintained Please follow instructions carefully Read and understand all instructions before ins...

Страница 2: ...umber Flush water supply line before connecting to fountain Water supplies with material such as sand rust etc may require a filter to keep valve working properly C Riser Tube Install a riser tube 4 a...

Страница 3: ...ing to the bottom of the unit along the outside edge of the fountain G Hold Downs The 100 150 150S and 300 fountains are provided with four built in hold downs and the 1000 fountain is provided with s...

Страница 4: ...s Wetting the plug can aid proper installation Tighten the wing nut to secure plug NOTE A third plug is supplied with the 1000 to allow for temporary shut off of the valve chamber L Install Valve Cove...

Страница 5: ...e may be electrical losses in the line due to long transmission distances A stainless steel heater stand is included and should be used with the Ritchie 500W heater to protect the fountain in the even...

Страница 6: ...ssure Low Water Flow a Check that valve inlet is not plugged or supply hose is not kinked b Check system pressure from supply hose by installing a tee and pressure gauge in front of the valve to check...

Страница 7: ...ie Label 12 1 pkg 1 pkg 4 16621 Access Panel 6 x14 1 12 18633 Plug 3 Water Channel 2 pkg 1 pkg 5 18147 Access Panel Hardware pkg 1 pkg NS 14866 Seal Foam 10 Roll 1 6 11515 Valve Bracket w screw pkg 1...

Страница 8: ...18653 Ritchie Label 12 1 pkg 1 pkg 4 16621 Access Panel 6 x14 1 12 18633 Plug 3 Water Channel 2 pkg 1 pkg 5 18147 Access Panel Hardware pkg 1 pkg NS 14866 Seal Foam 10 Roll 1 6 11515 Valve Bracket w...

Страница 9: ...abel 12 1 pkg 1 pkg 4 16621 Access Panel 6 x14 1 12 18633 Plug 3 Water Channel 2 pkg 1 pkg 5 18147 Access Panel Hardware pkg 1 pkg NS 14866 Seal Foam 10 Roll 2 6 11515 Valve Bracket w screw pkg 1 pkg...

Страница 10: ...4 16562 Access Panel 10 x20 1 12 18832 HP 3 4 Valve Assembly 1 5 18147 Access Panel Hardware pkg 1 pkg 13 18475 O Ring Valve Seal Pkg 4 pkg 1 6 18838 HP Bracket Assy Pkg 1 pkg NS 14866 Seal Foam 10 Ro...

Страница 11: ...4 16562 Access Panel 10 x20 1 12 18832 HP 3 4 Valve Assembly 1 5 18147 Access Panel Hardware pkg 1 pkg 13 18475 O Ring Valve Seal Pkg 4 pkg 1 6 18838 HP Bracket Assy Pkg 1 pkg NS 14866 Seal Foam 10 Ro...

Страница 12: ...nor to any product that is installed and or used contrary to Ritchie Industries installation instructions and instructions for use The limited warranty shall also not apply to any product whose exteri...

Отзывы: