Ritchie Classic Equine StallFount Скачать руководство пользователя страница 4

WARNING: DISCONNECT POWER IF THE WATER SUPPLY IS TO BE SHUT OFF FOR AN 
EXTENDED AMOUNT OF TIME. FAILURE TO TURN OFF POWER CAN RESULT IN DAMAGE TO 
THE WATERING FOUNTAIN. 

WARNING:  THIS INSTALLATION MUST BE MADE AND MAINTAINED IN STRICT CONFORMITY 
WITH NATIONAL/LOCAL PLUMBING CODES AND NATIONAL/LOCAL ELECTRICAL CODES (CSA 
IN CANADA). THE APPLICABLE PROVISIONS OF THESE CODES TAKE PRECEDENT. FAILURE 
TO MAKE AND MAINTAIN ALL INSTALLATIONS PROPERLY MAY RESULT IN LOSS OF 
LIVESTOCK, PERSONAL INJURY, OR DEATH.

  

NOTE:

 

National/Local electrical codes may require livestock waterers installed in feedlots in open feeding 

area to be grounded by a separate stranded copper grounding conductor or at least no.6 AWG 

terminating at a point where the branch circuit receives its supply. Check with local authorities.  

I.

 

Adjust Water Level – 

After the drain plug is installed, turn on water and adjust float to water level mark or 

until there is approximately 3 inches of water in trough.  Float is adjusted by loosening the wing-nut then raising or 

lowering the float as needed, and then re-tightening the wing-nut. When finished adjusting, reinstall the stainless-

steel cover with the two screws. 

J.

 

Installing the Shroud (Optional)

 – After the plumbing and electrical connections are made, install the shroud 

under the unit using 3/8" lag screws or bolts.  For irregular mounting surfaces, foam tape (included) may be applied 

to the mounting surfaces to eliminate air gaps.  Two-inch rigid insulation can be mounted against the stall walls, 

behind the shroud for maximum supply line protection in severe climates.

 

K.

 

Children should be supervised to ensure that they do not play with the appliance - 

This appliance is not 

intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of 

experience and knowledge, unless they have been given supervision or instructions concerning use of the appliance 

by a person responsible for their safety.

 

Troubleshooting 

Problem 

Solution 

Ice in Trough 

Check fuses or circuit breakers 

 

Check heating elements to make sure they are working and hot 

Check voltage after the thermostat to the fountain with and without electrical load. 

Supply line freezing 

Check that the cable heater is fastened to supply line and is working (hot). 

Check that supply piping is centered in riser tube and that there is air space between riser tube and 
supply line.  Ritchie Thermal Tubes are recommended as they have optimum inside and outside 
diameter to maximize insulation. 

Check that riser tube is free of water and mud that may freeze. 

Valve won’t shut off 

Check float adjustment.  Check for waterlogged float and free range of motion. 

Disassemble valve and check for sand or scale in valve rubber.  Also check valve orifice outlets 
for wear and damage.  A screen or filter may be required with sandy or scaly water 

Turn valve rubber over and re-assemble 

Check for excessive water system pressure (greater that 60 psi). May need to use pressure 
reducer. 

Low water flow 

Check that valve inlet is not plugged or supply hose is not kinked 

Check system pressure to unit.  A severe pressure drop indicates a restriction or undersized 
supply system. 

Check that shutoff valves are fully open. 

    

   

Classic Equine Stall Fount Instruction Manual

3

August 13, 2022

Содержание Classic Equine StallFount

Страница 1: ...ions you have just purchased the finest watering fountain on the market This unit is built to give you excellent service when properly installed and maintained Please follow instructions carefully Rea...

Страница 2: ...lines should be sized to account for pressure drop relating to distance and placed out of reach of livestock A one inch vertical supply pipe is recommended placed inside of a protective cover A shut...

Страница 3: ...tall the drain plug in the drain hole from above pushing the plug into the hole and tightening the wing nut to secure G Cable Heater Uncoil cable heater attach to the water supply with the cable twist...

Страница 4: ...m supply line protection in severe climates K Children should be supervised to ensure that they do not play with the appliance This appliance is not intended for use by persons including children with...

Страница 5: ...allfount Base 1 NS 18744 Shroud 20 1 6 18719 Classic Equine Logo pkg 2 pkg 1 pkg NS 18613 Adapter 1 2 NPT x 3 8 HB 1 pkg 7 13830 Cable Heater 120V 48 Watt 1 pkg NS 15930 Hose Clamp 5 pkg 1 pkg 8 11885...

Страница 6: ...to any product that is installed and or used contrary to Ritchie Industries installation instructions and instructions for use The limited warranty shall also not apply to any product whose exterior h...

Страница 7: ...This page intentionally left blank Classic Equine Stall Fount Instruction Manual 6 August 13 2022...

Страница 8: ...Part 24089 August 13 2022...

Отзывы: