WARNING: DISCONNECT POWER IF THE WATER SUPPLY IS TO BE SHUT OFF FOR AN
EXTENDED AMOUNT OF TIME. FAILURE TO TURN OFF POWER CAN RESULT IN DAMAGE TO
THE WATERING FOUNTAIN.
WARNING: THIS INSTALLATION MUST BE MADE AND MAINTAINED IN STRICT CONFORMITY
WITH NATIONAL/LOCAL PLUMBING CODES AND NATIONAL/LOCAL ELECTRICAL CODES (CSA
IN CANADA). THE APPLICABLE PROVISIONS OF THESE CODES TAKE PRECEDENT. FAILURE
TO MAKE AND MAINTAIN ALL INSTALLATIONS PROPERLY MAY RESULT IN LOSS OF
LIVESTOCK, PERSONAL INJURY, OR DEATH.
NOTE:
National/Local electrical codes may require livestock waterers installed in feedlots in open feeding
area to be grounded by a separate stranded copper grounding conductor or at least no.6 AWG
terminating at a point where the branch circuit receives its supply. Check with local authorities.
I.
Adjust Water Level –
After the drain plug is installed, turn on water and adjust float to water level mark or
until there is approximately 3 inches of water in trough. Float is adjusted by loosening the wing-nut then raising or
lowering the float as needed, and then re-tightening the wing-nut. When finished adjusting, reinstall the stainless-
steel cover with the two screws.
J.
Installing the Shroud (Optional)
– After the plumbing and electrical connections are made, install the shroud
under the unit using 3/8" lag screws or bolts. For irregular mounting surfaces, foam tape (included) may be applied
to the mounting surfaces to eliminate air gaps. Two-inch rigid insulation can be mounted against the stall walls,
behind the shroud for maximum supply line protection in severe climates.
K.
Children should be supervised to ensure that they do not play with the appliance -
This appliance is not
intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of
experience and knowledge, unless they have been given supervision or instructions concerning use of the appliance
by a person responsible for their safety.
Troubleshooting
Problem
Solution
Ice in Trough
Check fuses or circuit breakers
Check heating elements to make sure they are working and hot
Check voltage after the thermostat to the fountain with and without electrical load.
Supply line freezing
Check that the cable heater is fastened to supply line and is working (hot).
Check that supply piping is centered in riser tube and that there is air space between riser tube and
supply line. Ritchie Thermal Tubes are recommended as they have optimum inside and outside
diameter to maximize insulation.
Check that riser tube is free of water and mud that may freeze.
Valve won’t shut off
Check float adjustment. Check for waterlogged float and free range of motion.
Disassemble valve and check for sand or scale in valve rubber. Also check valve orifice outlets
for wear and damage. A screen or filter may be required with sandy or scaly water
Turn valve rubber over and re-assemble
Check for excessive water system pressure (greater that 60 psi). May need to use pressure
reducer.
Low water flow
Check that valve inlet is not plugged or supply hose is not kinked
Check system pressure to unit. A severe pressure drop indicates a restriction or undersized
supply system.
Check that shutoff valves are fully open.
Classic Equine Stall Fount Instruction Manual
3
August 13, 2022