Ritchie Classic Equine StallFount Скачать руководство пользователя страница 2

Fountain Installation Instructions  

A.

 

Installation of Stall Fount 

- The Stall Fount - Unheated and the Stall Fount - Heated are to be corner mounted 

and are designed to accept the water supply line from below, from above or from behind the fountain through the 

wall. 

Item 

No. 

Description 

Watts 

Amps 

 

Item 

No. 

Description 

Watts 

Amps 

18740 

Equine SF 120V 

173W  1.4A@120V    18741 

Equine SF 240V 

248W  1A@240V 

B.

 

Water Supply Line from  Underground 

 

Horizontal 

underground water line should be sized to account for 

pressure drop, relating to distance, and placed one foot below 

the  frost line.  A one-inch vertical supply pipe is 

recommended, placed inside of a riser tile. A shut-off valve 

(as pictured) should be installed under the fountain to allow 

for servicing. If your facility is cold in the winter,  using a 

Ritchie Thermal Tube  in combination with the insulated 

shroud will provide optimum protection to the vertical supply 

line against frost and freezing. 

C.

 

Water Supply from Overhead - 

Overhead water lines 

should be sized to account for pressure drop, relating to 

distance, and placed out of reach of livestock.  A one-inch 

vertical supply pipe is recommended, placed inside of a 

protective cover. A shut-off valve (as pictured) should be 

used at the fountain to allow for servicing. If your facility is 

cold in the winter, additional cold climate protection should 

be incorporated to protect the vertical supply line against frost 

and freezing. 

D.

 

Water Supply Through Wall - 

Through wall supply 

lines should be sized to account for pressure drop, relating to 

distance, and located to prevent tampering by livestock.  A one-inch 

supply pipe is recommended.  A shut-off valve should be located at 

the fountain to allow for servicing.  If your facility is cold in the 

winter, additional cold climate protection will be required. 

E.

 

Water Hose - 

The Stall Fount comes with a 3/8” rubber 

hose (30" long) which attaches to the supply pipe with a 3/8” hose 

barb and hose clamp.  When using a riser tube the vertical supply 

line it must be centered in tube below ground to provide an air space 

between the line and frozen ground outside of tube.  Do not 

Classic Equine Stall Fount Instruction Manual

1

August 13, 2022

Содержание Classic Equine StallFount

Страница 1: ...ions you have just purchased the finest watering fountain on the market This unit is built to give you excellent service when properly installed and maintained Please follow instructions carefully Rea...

Страница 2: ...lines should be sized to account for pressure drop relating to distance and placed out of reach of livestock A one inch vertical supply pipe is recommended placed inside of a protective cover A shut...

Страница 3: ...tall the drain plug in the drain hole from above pushing the plug into the hole and tightening the wing nut to secure G Cable Heater Uncoil cable heater attach to the water supply with the cable twist...

Страница 4: ...m supply line protection in severe climates K Children should be supervised to ensure that they do not play with the appliance This appliance is not intended for use by persons including children with...

Страница 5: ...allfount Base 1 NS 18744 Shroud 20 1 6 18719 Classic Equine Logo pkg 2 pkg 1 pkg NS 18613 Adapter 1 2 NPT x 3 8 HB 1 pkg 7 13830 Cable Heater 120V 48 Watt 1 pkg NS 15930 Hose Clamp 5 pkg 1 pkg 8 11885...

Страница 6: ...to any product that is installed and or used contrary to Ritchie Industries installation instructions and instructions for use The limited warranty shall also not apply to any product whose exterior h...

Страница 7: ...This page intentionally left blank Classic Equine Stall Fount Instruction Manual 6 August 13 2022...

Страница 8: ...Part 24089 August 13 2022...

Отзывы: