background image

WL T6S 

Wireless  

Shock Detector 

 

 

 

 

Installation 
Instructions 

 

 

 

United Kingdom 

Tel: +44-161-655-5500 
[email protected] 

USA 

Tel: +1-631-719-4400 
[email protected] 

Italy 

Tel: +39-02-66590054 
[email protected] 

Spain 

Tel: +34-91-490-2133 
[email protected] 

France 

Tel: +33-164-73-28-50 
[email protected] 

Belgium 

Tel: +32-2522-7622 
[email protected] 

Brazil 

Tel: +55-3661-8767  
[email protected] 

China 

Tel: +86-21-52-39-0066 
[email protected] 

Poland 

Tel: +48-22-500-28-40 
[email protected] 

Israel 

Tel: +972-3-963-7777 
[email protected]

 

RISCO Group Limited Warranty 

RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be 
free from defects in materials and workmanship under normal use for 24 months from 
the date of production. Because Seller does not install or connect the product and 
because the product may be used in conjunction with products not manufactured by the 
Seller, Seller cannot guarantee the performance of the security system which uses this 
product. Seller's obligation and liability under this warranty is expressly limited to 
repairing and replacing, at Seller's option, within a reasonable time after the date of 
delivery, any product not meeting the specifications. Seller makes no other warranty, 
expressed or implied, and makes no warranty of merchantability or of fitness for any 
particular purpose. 
In no case shall seller be liable for any consequential or incidental damages for breach 
of this or any other warranty, expressed or implied, or upon any other basis of liability 
whatsoever. 
Seller's obligation under this warranty shall not include any transportation charges or 
costs of installation or any liability for direct, indirect, or consequential damages or 
delay.  
Seller does not represent that its product may not be compromised or circumvented; 
that the product will prevent any personal injury or property loss by burglary, robbery, 
fire or otherwise; or that the product will in all cases provide adequate warning or 
protection.  
Buyer understands that a properly installed and maintained alarm may only reduce the 
risk of burglary, robbery or fire without warning, but is not insurance or a guaranty that 
such event will not occur or that there will be no personal injury or property loss as a 
result thereof. 
Consequently seller shall have no liability for any personal injury, property damage or 
loss based on a claim that the product fails to give warning. However, if seller is held 
liable, whether directly or indirectly, for any loss or damage arising under this limited 
warranty or otherwise, regardless of cause or origin, seller's maximum liability shall not 
exceed the purchase price of the product, which shall be complete and exclusive 
remedy against seller. No employee or representative of Seller is authorized to change 
this warranty in any way or grant any other warranty. 

NOTE

: This product should be tested at least once a week.

 

 
 

FCC NOTE (for 433MHz versions only):

 

This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC rules.  These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the 
user is encouraged to try to correct the interference by one or more of the following 
measures: 
a)  Reorient or relocate the receiving antenna. 
b)  Increase the separation between the equipment and receiver. 
c)  Connect the equipment to an outlet on a circuit different from that to which the receiver 

is connected. 

d)  Consult the dealer or an experienced radio/TV technician. 

FCC Warning

 

The manufacturer is not responsible for any radio or TV interference caused by 
unauthorized modifications to this equipment. Such modifications could void the user's 
authority to operate the equipment. 

FCC ID: JE4RWT71X433

 

 

RTTE Compliance Statement

 

Hereby, RISCO Group declares that this equipment is in compliance 
with the essential requirements and other relevant provisions of Directive 
1999/5/EC. 
For the CE Declaration of Conformity please refer to our website: 

www.riscogroup.com.

 

 

 
 
© RISCO Group 03/13

 

5IN1341 B

 

                                                           
                              
                              

ENGLISH

 

GENERAL DESCRIPTION 

The WL T6S is a Shock detector intended for internal use 
that provides reliable 24-hour perimeter protection. 
The detector employs an advanced digital microprocessor 
to analyze the vibration signal received from the piezo 
electric sensor. 
This detector operates in conjunction with RISCO's 
programmable receivers and is powered by a standard 3-
volt lithium battery. 

MAIN FEATURES 

•  Digital Microprocessor with Intelligent Digital Signal 
Processing 
•  Tri-color LED enables accurate and reliable calibration, 

with “over-sensitive” and “under-sensitive” indications 

•  Gross attack detections 
•  Encapsulated bi-morph piezo electric sensor 
•  Dual stage adjustment potentiometer  
•  Back & Cover tamper protection 

•  Operates up to 300m (1000 ft) range (LOS) 

•  Uses one of more than 16 million addresses codes 

 

•  Fully supervised  

DIPSWITCHES 

Dipswitch 

Description 

Used to enable or disable LED

 

Dipswitch Position 

LED 

ON 

(Default)

 

Enabled 

OFF 

Disabled 

Used to determine the sensitivity of the Shock detector 

 

Dipswitch Position 

Sensitivity 

ON 

(Default)

 

High 

OFF 

Low 

NOTE

: For fine tuning use the sensitivity trimmer.

 

Used to determine the time between the transmitter 
supervision messages.

 

Dipswitch Position 

Supervision Time 

ON 

65 minutes

 

OFF 

(Default)

 

15 minutes

 

Not used 

 

Not used 

 

Used to determine the detector RF power 

Dipswitch Position 

RF Power Transmission 

ON 

Low 

OFF 

(Default)

 

High 

 

LED INDICATION 

After each detection, the LED turns ON momentarily. 
On Low Battery condition, the LED will blink during each transmission. 

 

GREEN

 

Indicates an alarm condition

  

RED

 

•  Under-Sensitive indication  
•  Tamper indication 
•  Write message 

ORANGE

 

Over-Sensitive indication

  

FRONT COVER REMOVAL 

Remove the front cover as described in Figure 2.

 

TRANSMITTER/RECEIVER COMMUNICATION SET UP 

The t

ransmitter must identify itself to the system’s receiver by writing its 

coded messages into the receiver’s address memory. This is accomplished 
by performing the following steps: 
a. Set the receiver to the Write Mode (follow the receiver’s instructions). 
b. Remove the battery from the insulation material and reinsert it into the 

transmitter, paying attention to the polarity (see Fig. 3). 

c. Send a Write message by pressing both tamper buttons for at least 3 

seconds. 

d. Set the receiver to the Normal mode.  
e. Verify that the receiver has identified the detector by generating a tamper 

signal (by momentarily closing and opening both tampers).  

 

NOTE

: If for any reason it is necessary to re-send a write message, press both 

of the tamper buttons (back and cover) for at least 3 seconds.

 

 

INSTALLATION INSTRUCTIONS 

Considerations for wireless communication 

a. For best wireless communication, place the unit at the highest 

possible position. 

b. Temporarily attach the unit to this point using two sided adhesive 

tape. 

c. Generate an Alarm or Tamper signal and verify that the receiver 

has received the signal. If the signal is not detected, reposition the 
transmitter and try again. 

Considerations for installation 

1. Select the intended position for installation, ensuring the surface is 

clean and clear of any irregularities. Refer to Table 1 for details 
about detection ranges for the different surface types. 

2. Set the detector’s sensitivity as follows, using the sensitivity 

trimmer: 

i.   With the unit set for normal operation, use a suitable  

 instrument to bang or tap the protected area. 

ii.  If the sensitivity needs adjustment, use a screwdriver to  

adjust the trimmer (turn the trimmer control clockwise to  
increase sensitivity or counter-clockwise to reduce  
sensitivity).     

iii. Repeat steps i and ii until the desired sensitivity level is  

achieved. If required, you can set Dipswitch 2 to OFF to  
reduce sensitivity range. 

3. Close the front cover.

 

 

Table 1: Typical Detection Range

 

Surface  Concrete  Brick Wall 

Steel 

Glass 

Wood 

Plywood 

Radius 

1.5m (5ft)  2.5m (8.2ft)  3m (10ft)  3.5m (11.5ft)  3.5m (11.5ft)  4m (13ft) 

The above values are typical and are subject to practical testing, 
which must be performed for each installation. In some environments, 
these values may differ from the values listed above.

 

FINAL MOUNTING  

Separate the back part of the transmitter (Fig. 4), and mount all the 
parts in place (Fig. 5).

 

SPECIFICATIONS 

ELECTRICAL

 

Battery Type:

 

CR123 3V Lithium Battery 

Current Consumption:

 

10µA standby 

Frequency:

 

433.92 / 868.65 MHz

 

Supervision Transmission:

 

Every 15/65 minutes 

Modulation Type:

 

ASK 

Battery Life:  

5 years depends on usage

 

PHYSICAL

 

Size:

 

81x35x32mm (3.2x1.37x1.27in.) 

ENVIRONMENTAL

 

RF immunity:

 

According to EN-50130-4

 

Operating temperature:

 

0°C to 55°C (32°F to 131°F) 

Storage temperature:

 

-20°C to 60°C (-4°F to 140°F) 

Maximum humidity:

 

95% non-condensing

 

Specifications are subject to change without prior notice. 
Should any questions arise please contact your supplier. 

 

FRANÇAIS

 

DESCRIPTION GENERALE 

Le détecteur de Choc WL T6S est destiné à une utilisation 
intérieure qui offre une protection périmétrique fiable 
24h/24. Gr

âce à son microprocesseur numérique de 

pointe, le d

étecteur analyse tout signal de vibration qui lui 

est envoy

é par le capteur piézo-électrique.  

Aliment

é par une pile au lithium de 3V standard, il 

fonctionne en combinaison avec les r

écepteurs 

programmables de RISCO.  

CARACTERISTIQUES PRINCIPALES  

•  Microprocesseur avec traitement intelligent du signal 

num

érique  

•  Diode électroluminescente tricolore (LED) pour un 

calibrage pr

écis et fiable, avec indications "d'excès" et 

"d'insuffisance" de sensibilit

é 

•  Détection d'attaques brutales 
•  Capteur piézo-électrique bimorphe intégré 
•  Potentiomètre à double réglage 
•  Autoprotection à l'arrachement et à l'ouverture  
•  Portée allant jusqu'à 300 m. (1000 ft.) (Champ libre) 
•  Utilise un code d'adresse parmis plus de 16 millions  
•  Durée de vie étendue de la pile 
•  Entièrement supervisé 

 

DIPSWITCHES 

Dipswitch  Description 

Utilisé pour activer ou désactiver la LED

 

Position du DIP  LED 
ON 

(par défaut))

 

Activé 

OFF 

Désactivé 

Utilisé pour déterminer la sensibilité du détecteur de choc

 

Position du DIP  Sensibilité 
ON 

(par défaut)

 

Elevée 

OFF 

Faible 

NOTE 

: Pour un réglage fin, utiliser le potentiomètre de 

sensibilité.

 

Utilisé pour déterminer le délai entre l’envoie des messages 
de supervision du transmetteur.

 

Position du DIP  Délai de Supervision 
ON 

65 minutes 

OFF 

(par défaut)

 

15 minutes 

Inutilisé 

Inutilisé 

Sert à déterminer la puissance de transmission RF. 

Position du DIP  Transmission RF 
ON 

Elevée 

OFF 

(par défaut)

 

Faible 

 

INDICATIONS LED 

Apr

ès chaque détection, la diode LED s'allume momentanément. 

Lorsque la pile est faible (batterie faible) 

– la diode LED clignote à chaque 

transmission. 

 

VERTE 

Indique une condition d'alarme 

 

ROUGE 

•  Indique une insuffisance de sensibilité  
•  Indication de sabotage 
•  Message d'écriture 

ORANGE

 

Indique un exc

ès de sensibilité

  

RETRAIT DU COUVERCLE FRONTAL 

Enlever le couvercle comme décrit en figure 2.

 

PARAMETRAGE DE LA COMMUNICATION 
TRANSMETTEUR/ R

ÉCEPTEUR 

Le transmetteur doit s'identifier aupr

ès du récepteur du système en 

inscrivant ses messages cod

és dans le registre d'adresses du récepteur. 

Cette op

ération s'accomplit en exécutant les étapes suivantes : 

a. R

églez le récepteur en mode écriture (suivez pour cela les instructions 

correspondantes). 

b. Retirez la pile de sa protection isolante et r

éinsérez-la dans le 

transmetteur en respectant la polarit

é indiquée (cf. fig. 3). 

c. Envoyez un message d'écriture en appuyant sur les deux contacts 

d'autoprotection pendant au moins 3 secondes.

 

d. R

églez le récepteur en mode normal. 

e. V

érifiez que détecteur a bien été identifié par le récepteur : pour cela, 

g

énérez un signal d'autoprotection (en fermant et ouvrant 

momentan

ément les deux AP). 

REMARQUE 

: si pour une raison quelconque, il s'av

ère nécessaire de renvoyer 

un message d’écriture, il suffit pour cela d'appuyer simultanément sur les deux 
contacts d'autoprotection (arri

ère et couvercle) pendant au moins 3 secondes. 

 

INSTRUCTIONS D'INSTALLATION 

Considérations pour la communication sans fil 

a. Pour une meilleure communication, placez l'appareil le plus haut 

possible. 

b. Fixez provisoirement l'appareil en ce point en utilisant de l'adh

ésif 

double face. 

c. Générer un signal d'alarme ou d'AP et v

érifiez que le récepteur a 

bien re

çu le signal. Si le signal d'alarme n'a pas été détecté, 

repositionnez le transmetteur et r

éessayez. 

Considérations 

pour l’installation 

1. Choisissez l'endroit souhaité pour l'installation, en vous assurant 

que la surface est bien propre et nette de toutes asp

érités. Se 

reporter au tableau 1 pour consulter les port

ées de détection selon 

les diff

érents types de surfaces. 

2. Ajuster la sensibilit

é du détecteur comme suit, en vous servant du 

potentiomètre de sensibilit

é : 

(i)  L'appareil 

étant en mode de fonctionnement normal, feignez, à 

l'aide d'un instrument adapt

é, une intrusion (en cognant ou 

frappant) au sein de la zone prot

égée. 

(ii)  Si la sensibilit

é requiert un ajustement, ajustez le réglage à 

l'aide d'un tournevis (dans le sens des aiguilles d'une montre 
pour augmenter la sensibilit

é, et dans le sens inverse pour la 

r

éduire).   

(iii) Renouvelez les 

étapes (i) et (ii) jusqu'  

à obtenir le niveau de 

sensibilit

é souhaité. Si nécessaire, vous pouvez mettre le 

Dipswitch 2 sur OFF pour réduire la sensibilité. 

3. Fermez le couvercle frontal. 

 

 

Tableau 1 : Port

ées typiques de détection 

Surface 

Béton  Mur de briques  Acier  Verre 

Bois 

Contreplaqué 

Rayon 

1,5 m 

2,5 m 

3m 

3,5 m 

3,5 m 

4m 

Les valeurs indiqu

ées ci-dessus sont des valeurs typiques et doivent 

être soumises à un test pratique à réaliser à chaque installation. Dans 
certains environnements, ces valeurs peuvent 

être différentes de 

celles du tableau ci-dessus.

 

ASSEMBLAGE FINAL 

S

éparez la partie arrière de l’émetteur (Fig. 4), et montez toutes les 

pi

èces (Fig. 5).

 

SPECIFICATIONS 

ELECTRIQUES 

Type de batterie :

 

pile lithium 3V CR123  

Consommation 

électrique :

 

10µA en veille 

Fr

équence :

 

433.92 / 868.65 MHz

 

Transmission de supervision :

 

toutes les 15 / 65 minutes 

Type de modulation :

 

ASK 

Dur

ée de vie de la pile :  

5 ans selon utilisation

 

PHYSIQUES

 

Dimensions :

 

81 x 35 x 32 mm 

ENVIRONNEMENTALES

 

Immunit

é RF :

 

selon la norme EN-50130-4

 

Temp

érature de 

fonctionnement :

 

de 0°C 

à 55°C 

Temp

érature de stockage :

 

de -20°C 

à 60°C 

Humidit

é maximum :

 

95% sans condensation

 

Ces sp

écifications sont susceptibles d'être modifiées sans avis préalable. 

Si vous avez des questions, veuillez contacter votre fournisseur. 

 

ESPAÑOL

 

INTERRUPTORES DIP 

INDICACI

ÓN LED 

Despu

és de cada detección, el LED se enciende momentáneamente. 

 

INSTRUCCIONES DE INSTALACIÓN 

Tabla 1: Alcance T

ípico de Detección 

Superficie  Cemento  Ladrillo 

Acero 

Vidrio 

Madera 

Contrachapado 

D

©

 R

IS

C

O

B

A

T

T

E

R

Y

+

-

S

W
1

P

IE

Z

O

 S

E

N

S

O

R

M

IN

 M

A

X

A

N

T

E

N

N

A

S

W
2

x

DIPSWITCH

L

E

D

ON

1 2 3 4 5 6

Fig. 1

Отзывы: