WL T6S
Wireless
Shock Detector
Installation
Instructions
United Kingdom
Tel: +44-161-655-5500
[email protected]
USA
Tel: +1-631-719-4400
[email protected]
Italy
Tel: +39-02-66590054
[email protected]
Spain
Tel: +34-91-490-2133
[email protected]
France
Tel: +33-164-73-28-50
[email protected]
Belgium
Tel: +32-2522-7622
[email protected]
Brazil
Tel: +55-3661-8767
[email protected]
China
Tel: +86-21-52-39-0066
[email protected]
Poland
Tel: +48-22-500-28-40
[email protected]
Israel
Tel: +972-3-963-7777
[email protected]
RISCO Group Limited Warranty
RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be
free from defects in materials and workmanship under normal use for 24 months from
the date of production. Because Seller does not install or connect the product and
because the product may be used in conjunction with products not manufactured by the
Seller, Seller cannot guarantee the performance of the security system which uses this
product. Seller's obligation and liability under this warranty is expressly limited to
repairing and replacing, at Seller's option, within a reasonable time after the date of
delivery, any product not meeting the specifications. Seller makes no other warranty,
expressed or implied, and makes no warranty of merchantability or of fitness for any
particular purpose.
In no case shall seller be liable for any consequential or incidental damages for breach
of this or any other warranty, expressed or implied, or upon any other basis of liability
whatsoever.
Seller's obligation under this warranty shall not include any transportation charges or
costs of installation or any liability for direct, indirect, or consequential damages or
delay.
Seller does not represent that its product may not be compromised or circumvented;
that the product will prevent any personal injury or property loss by burglary, robbery,
fire or otherwise; or that the product will in all cases provide adequate warning or
protection.
Buyer understands that a properly installed and maintained alarm may only reduce the
risk of burglary, robbery or fire without warning, but is not insurance or a guaranty that
such event will not occur or that there will be no personal injury or property loss as a
result thereof.
Consequently seller shall have no liability for any personal injury, property damage or
loss based on a claim that the product fails to give warning. However, if seller is held
liable, whether directly or indirectly, for any loss or damage arising under this limited
warranty or otherwise, regardless of cause or origin, seller's maximum liability shall not
exceed the purchase price of the product, which shall be complete and exclusive
remedy against seller. No employee or representative of Seller is authorized to change
this warranty in any way or grant any other warranty.
NOTE
: This product should be tested at least once a week.
FCC NOTE (for 433MHz versions only):
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
a) Reorient or relocate the receiving antenna.
b) Increase the separation between the equipment and receiver.
c) Connect the equipment to an outlet on a circuit different from that to which the receiver
is connected.
d) Consult the dealer or an experienced radio/TV technician.
FCC Warning
The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the user's
authority to operate the equipment.
FCC ID: JE4RWT71X433
RTTE Compliance Statement
Hereby, RISCO Group declares that this equipment is in compliance
with the essential requirements and other relevant provisions of Directive
1999/5/EC.
For the CE Declaration of Conformity please refer to our website:
www.riscogroup.com.
© RISCO Group 03/13
5IN1341 B
ENGLISH
GENERAL DESCRIPTION
The WL T6S is a Shock detector intended for internal use
that provides reliable 24-hour perimeter protection.
The detector employs an advanced digital microprocessor
to analyze the vibration signal received from the piezo
electric sensor.
This detector operates in conjunction with RISCO's
programmable receivers and is powered by a standard 3-
volt lithium battery.
MAIN FEATURES
• Digital Microprocessor with Intelligent Digital Signal
Processing
• Tri-color LED enables accurate and reliable calibration,
with “over-sensitive” and “under-sensitive” indications
• Gross attack detections
• Encapsulated bi-morph piezo electric sensor
• Dual stage adjustment potentiometer
• Back & Cover tamper protection
• Operates up to 300m (1000 ft) range (LOS)
• Uses one of more than 16 million addresses codes
• Fully supervised
DIPSWITCHES
Dipswitch
Description
1
Used to enable or disable LED
Dipswitch Position
LED
ON
(Default)
Enabled
OFF
Disabled
2
Used to determine the sensitivity of the Shock detector
Dipswitch Position
Sensitivity
ON
(Default)
High
OFF
Low
NOTE
: For fine tuning use the sensitivity trimmer.
3
Used to determine the time between the transmitter
supervision messages.
Dipswitch Position
Supervision Time
ON
65 minutes
OFF
(Default)
15 minutes
4
Not used
5
Not used
6
Used to determine the detector RF power
Dipswitch Position
RF Power Transmission
ON
Low
OFF
(Default)
High
LED INDICATION
After each detection, the LED turns ON momentarily.
On Low Battery condition, the LED will blink during each transmission.
GREEN
Indicates an alarm condition
RED
• Under-Sensitive indication
• Tamper indication
• Write message
ORANGE
Over-Sensitive indication
FRONT COVER REMOVAL
Remove the front cover as described in Figure 2.
TRANSMITTER/RECEIVER COMMUNICATION SET UP
The t
ransmitter must identify itself to the system’s receiver by writing its
coded messages into the receiver’s address memory. This is accomplished
by performing the following steps:
a. Set the receiver to the Write Mode (follow the receiver’s instructions).
b. Remove the battery from the insulation material and reinsert it into the
transmitter, paying attention to the polarity (see Fig. 3).
c. Send a Write message by pressing both tamper buttons for at least 3
seconds.
d. Set the receiver to the Normal mode.
e. Verify that the receiver has identified the detector by generating a tamper
signal (by momentarily closing and opening both tampers).
NOTE
: If for any reason it is necessary to re-send a write message, press both
of the tamper buttons (back and cover) for at least 3 seconds.
INSTALLATION INSTRUCTIONS
Considerations for wireless communication
a. For best wireless communication, place the unit at the highest
possible position.
b. Temporarily attach the unit to this point using two sided adhesive
tape.
c. Generate an Alarm or Tamper signal and verify that the receiver
has received the signal. If the signal is not detected, reposition the
transmitter and try again.
Considerations for installation
1. Select the intended position for installation, ensuring the surface is
clean and clear of any irregularities. Refer to Table 1 for details
about detection ranges for the different surface types.
2. Set the detector’s sensitivity as follows, using the sensitivity
trimmer:
i. With the unit set for normal operation, use a suitable
instrument to bang or tap the protected area.
ii. If the sensitivity needs adjustment, use a screwdriver to
adjust the trimmer (turn the trimmer control clockwise to
increase sensitivity or counter-clockwise to reduce
sensitivity).
iii. Repeat steps i and ii until the desired sensitivity level is
achieved. If required, you can set Dipswitch 2 to OFF to
reduce sensitivity range.
3. Close the front cover.
Table 1: Typical Detection Range
Surface Concrete Brick Wall
Steel
Glass
Wood
Plywood
Radius
1.5m (5ft) 2.5m (8.2ft) 3m (10ft) 3.5m (11.5ft) 3.5m (11.5ft) 4m (13ft)
The above values are typical and are subject to practical testing,
which must be performed for each installation. In some environments,
these values may differ from the values listed above.
FINAL MOUNTING
Separate the back part of the transmitter (Fig. 4), and mount all the
parts in place (Fig. 5).
SPECIFICATIONS
ELECTRICAL
Battery Type:
CR123 3V Lithium Battery
Current Consumption:
10µA standby
Frequency:
433.92 / 868.65 MHz
Supervision Transmission:
Every 15/65 minutes
Modulation Type:
ASK
Battery Life:
5 years depends on usage
PHYSICAL
Size:
81x35x32mm (3.2x1.37x1.27in.)
ENVIRONMENTAL
RF immunity:
According to EN-50130-4
Operating temperature:
0°C to 55°C (32°F to 131°F)
Storage temperature:
-20°C to 60°C (-4°F to 140°F)
Maximum humidity:
95% non-condensing
Specifications are subject to change without prior notice.
Should any questions arise please contact your supplier.
FRANÇAIS
DESCRIPTION GENERALE
Le détecteur de Choc WL T6S est destiné à une utilisation
intérieure qui offre une protection périmétrique fiable
24h/24. Gr
âce à son microprocesseur numérique de
pointe, le d
étecteur analyse tout signal de vibration qui lui
est envoy
é par le capteur piézo-électrique.
Aliment
é par une pile au lithium de 3V standard, il
fonctionne en combinaison avec les r
écepteurs
programmables de RISCO.
CARACTERISTIQUES PRINCIPALES
• Microprocesseur avec traitement intelligent du signal
num
érique
• Diode électroluminescente tricolore (LED) pour un
calibrage pr
écis et fiable, avec indications "d'excès" et
"d'insuffisance" de sensibilit
é
• Détection d'attaques brutales
• Capteur piézo-électrique bimorphe intégré
• Potentiomètre à double réglage
• Autoprotection à l'arrachement et à l'ouverture
• Portée allant jusqu'à 300 m. (1000 ft.) (Champ libre)
• Utilise un code d'adresse parmis plus de 16 millions
• Durée de vie étendue de la pile
• Entièrement supervisé
DIPSWITCHES
Dipswitch Description
1
Utilisé pour activer ou désactiver la LED
Position du DIP LED
ON
(par défaut))
Activé
OFF
Désactivé
2
Utilisé pour déterminer la sensibilité du détecteur de choc
Position du DIP Sensibilité
ON
(par défaut)
Elevée
OFF
Faible
NOTE
: Pour un réglage fin, utiliser le potentiomètre de
sensibilité.
3
Utilisé pour déterminer le délai entre l’envoie des messages
de supervision du transmetteur.
Position du DIP Délai de Supervision
ON
65 minutes
OFF
(par défaut)
15 minutes
4
Inutilisé
5
Inutilisé
6
Sert à déterminer la puissance de transmission RF.
Position du DIP Transmission RF
ON
Elevée
OFF
(par défaut)
Faible
INDICATIONS LED
Apr
ès chaque détection, la diode LED s'allume momentanément.
Lorsque la pile est faible (batterie faible)
– la diode LED clignote à chaque
transmission.
VERTE
Indique une condition d'alarme
ROUGE
• Indique une insuffisance de sensibilité
• Indication de sabotage
• Message d'écriture
ORANGE
Indique un exc
ès de sensibilité
RETRAIT DU COUVERCLE FRONTAL
Enlever le couvercle comme décrit en figure 2.
PARAMETRAGE DE LA COMMUNICATION
TRANSMETTEUR/ R
ÉCEPTEUR
Le transmetteur doit s'identifier aupr
ès du récepteur du système en
inscrivant ses messages cod
és dans le registre d'adresses du récepteur.
Cette op
ération s'accomplit en exécutant les étapes suivantes :
a. R
églez le récepteur en mode écriture (suivez pour cela les instructions
correspondantes).
b. Retirez la pile de sa protection isolante et r
éinsérez-la dans le
transmetteur en respectant la polarit
é indiquée (cf. fig. 3).
c. Envoyez un message d'écriture en appuyant sur les deux contacts
d'autoprotection pendant au moins 3 secondes.
d. R
églez le récepteur en mode normal.
e. V
érifiez que détecteur a bien été identifié par le récepteur : pour cela,
g
énérez un signal d'autoprotection (en fermant et ouvrant
momentan
ément les deux AP).
REMARQUE
: si pour une raison quelconque, il s'av
ère nécessaire de renvoyer
un message d’écriture, il suffit pour cela d'appuyer simultanément sur les deux
contacts d'autoprotection (arri
ère et couvercle) pendant au moins 3 secondes.
INSTRUCTIONS D'INSTALLATION
Considérations pour la communication sans fil
a. Pour une meilleure communication, placez l'appareil le plus haut
possible.
b. Fixez provisoirement l'appareil en ce point en utilisant de l'adh
ésif
double face.
c. Générer un signal d'alarme ou d'AP et v
érifiez que le récepteur a
bien re
çu le signal. Si le signal d'alarme n'a pas été détecté,
repositionnez le transmetteur et r
éessayez.
Considérations
pour l’installation
1. Choisissez l'endroit souhaité pour l'installation, en vous assurant
que la surface est bien propre et nette de toutes asp
érités. Se
reporter au tableau 1 pour consulter les port
ées de détection selon
les diff
érents types de surfaces.
2. Ajuster la sensibilit
é du détecteur comme suit, en vous servant du
potentiomètre de sensibilit
é :
(i) L'appareil
étant en mode de fonctionnement normal, feignez, à
l'aide d'un instrument adapt
é, une intrusion (en cognant ou
frappant) au sein de la zone prot
égée.
(ii) Si la sensibilit
é requiert un ajustement, ajustez le réglage à
l'aide d'un tournevis (dans le sens des aiguilles d'une montre
pour augmenter la sensibilit
é, et dans le sens inverse pour la
r
éduire).
(iii) Renouvelez les
étapes (i) et (ii) jusqu'
à obtenir le niveau de
sensibilit
é souhaité. Si nécessaire, vous pouvez mettre le
Dipswitch 2 sur OFF pour réduire la sensibilité.
3. Fermez le couvercle frontal.
Tableau 1 : Port
ées typiques de détection
Surface
Béton Mur de briques Acier Verre
Bois
Contreplaqué
Rayon
1,5 m
2,5 m
3m
3,5 m
3,5 m
4m
Les valeurs indiqu
ées ci-dessus sont des valeurs typiques et doivent
être soumises à un test pratique à réaliser à chaque installation. Dans
certains environnements, ces valeurs peuvent
être différentes de
celles du tableau ci-dessus.
ASSEMBLAGE FINAL
S
éparez la partie arrière de l’émetteur (Fig. 4), et montez toutes les
pi
èces (Fig. 5).
SPECIFICATIONS
ELECTRIQUES
Type de batterie :
pile lithium 3V CR123
Consommation
électrique :
10µA en veille
Fr
équence :
433.92 / 868.65 MHz
Transmission de supervision :
toutes les 15 / 65 minutes
Type de modulation :
ASK
Dur
ée de vie de la pile :
5 ans selon utilisation
PHYSIQUES
Dimensions :
81 x 35 x 32 mm
ENVIRONNEMENTALES
Immunit
é RF :
selon la norme EN-50130-4
Temp
érature de
fonctionnement :
de 0°C
à 55°C
Temp
érature de stockage :
de -20°C
à 60°C
Humidit
é maximum :
95% sans condensation
Ces sp
écifications sont susceptibles d'être modifiées sans avis préalable.
Si vous avez des questions, veuillez contacter votre fournisseur.
ESPAÑOL
INTERRUPTORES DIP
INDICACI
ÓN LED
Despu
és de cada detección, el LED se enciende momentáneamente.
INSTRUCCIONES DE INSTALACIÓN
Tabla 1: Alcance T
ípico de Detección
Superficie Cemento Ladrillo
Acero
Vidrio
Madera
Contrachapado
D
©
R
IS
C
O
B
A
T
T
E
R
Y
+
-
S
W
1
P
IE
Z
O
S
E
N
S
O
R
M
IN
M
A
X
A
N
T
E
N
N
A
S
W
2
x
DIPSWITCH
L
E
D
ON
1 2 3 4 5 6
Fig. 1