Engineer Programming
Page 80
Quick Keys
Parameter
Default
Range
Sounder Auxiliary =
Tamper
No
Yes/No
This parameter relates to the bus sounder.
YES
: A sounder auxiliary fault will be regarded as tamper alarm by the
system.
NO
: A sounder auxiliary fault will be regarded as fault by the system.
Labels
The System Labels menu enables you to modify the labels displayed by the LCD that identify
the system and partition labels. For changing labels from the keypad refer to page 80
System: Labels
Quick Keys
Parameter
Default
Range
System
Security System
Any 16 Characters
Edits the global(system label)
to
Partitions 1 through 4
Partition 1 through
Partition 4
Any 16 Characters
Sounds
The Sounds menu contains parameters that enable you to set the sound(s) that will be
produced after the following system events.
Tamper Sound
Sets the sound(s) produced by a Tamper violation of a keypad and/or an
expansion module, as follows:
Silent
— Produces no sound
Bell
(External Sounder) Only
Buzzer
(Keypad Piezo) Only
Bell + Buzzer
System: Sounds: Tamper
Quick Keys
Parameter
Default
Range
During Unset
Buzzer
–
Sets the sound produced by tamper violation while the system is unset
Содержание LightSYS
Страница 1: ...Installation and Programming Manual ...