Mounting and Wiring
Page
19
1.
Connection to AC must be permanent and connect through the mains-
fuse terminal block (see Figure
A.
Affix AC adapter as per placement struts.
B.
According to the location of the electrical and communication
outlets, remove the knockouts to allow cable and wire passage
for routing through the right or left-side (default) knockout
exit.
C.
Do not connect the cable to the wall power supply at this
point.
Figure
2-3 Placing the AC adapter with mains fuse
Caution:
When the main panel is powered on, mains voltage is present on the main
PCB.
To prevent risk of electric shock, disconnect all power (AC transformer
and battery) and phone cords before servicing.
Under no circumstances should mains power be connected to the PCB
other than to the main terminal block.
A readily accessible disconnect device shall be incorporated in the
building installation wiring.
For continued protection against risk of fire, replace fuses only with fuses
of the same type and rating.
2.
Place the main panel on its four mounting brackets and secure it, as per
Figure