Panda Keypad Indicators

 

Fault 

On:

 System Fault 

Off:

 System operating 

normally

 

 Ready

 

On:

 Ready to set 

Off:

 Not ready to set 

Slow flash:

 System is 

ready to be set while 
exit/entry zone is open

 

 Set

 

On:

 System is armed in Full Set 

or Part Set mode 

Off:

 System unset 

Slow flash:

 System in Exit Delay  

Rapid flash:

 Alarm 

 

Partial (Stay) Set / Omit

On:

 System is Part Set mode 

or Zone Omit mode 

Off:

 No omitted zones

 

 

Tamper

 

On:

 Tamper alarm 

Off:

 No tamper alarm

 

 

Cloud connectivity

 

On:

 System connected to cloud 

Off:

 No cloud connection 

configured 

Slow flash:

 Cloud 

connectivity fault 

 

2-way Slim Keypad 

 

LED Indicator 
Color State  Status 

Blue Blink

 

During communication with the 
panel 

Red On 

Slow flash 
Rapid flash 

System fully or partially set 
During exit delay 
During alarm 

Green Blink  Fault 

indication in the system while 

the system is unset* 

Green/Red

 

Toggle 

Waiting for code to be entered 

 

 

Содержание lightsys 2

Страница 1: ...it appears on the panel or supplied by the installer also available in the keypad menu as described below 6 Complete registration form and click Register 7 To complete registration open the email mes...

Страница 2: ...t Duress Code Panic Alarm Pressing simultaneously for 2 seconds Fire Alarm Pressing simultaneously for 2 seconds Medical Alarm Pressing simultaneously for 2 seconds Quick Zones Omit Code Zone No Activ...

Страница 3: ...lence an Alarm Code Partition Full Set Code Partition No Partition Part Set Code Partition No Partition Unset Code Partition No Duress Unset Duress Code Panic Alarm Pressing simultaneously for 2 secon...

Страница 4: ...Pressing simultaneously for 2 seconds Fire Alarm Pressing simultaneously for 2 seconds Medical Alarm Pressing simultaneously for 2 seconds Quick Zones Omit Code Zone No Activate Output Code Activitie...

Страница 5: ...Code Partition Unset Select partition 1 2 3 4 and press followed by Code Panic alarm Press simultaneously for 2 seconds Fire alarm Press simultaneously for 2 seconds Emergency Med alarm Press simultan...

Страница 6: ...econds Code Panic Alarm simultaneously for 2 seconds Clear Operation Notes For Part setting with no entry delay press and hold for two seconds 1 Consult your engineer for the operations defined with a...

Страница 7: ...on System Unset Code Partition Unset Detector Omit On Off toggle Web Application SET UNSET Full Set All Partitions or PARTITION x Full Set Full Set Group if suppored Group Letter Full Set Or PARTITION...

Страница 8: ...ME ZONE HISTORY Review activity log and export AUTOMATION Programmable Outputs Toggle ON OFF Update Indicators LCD and Touchscreen Keypads Power On Power OK No faults Off No power Rapid Flash System f...

Страница 9: ...y Set Omit On System is Part Set mode or Zone Omit mode Off No omitted zones Tamper On Tamper alarm Off No tamper alarm Cloud connectivity On System connected to cloud Off No cloud connection configur...

Страница 10: ...he new code followed by 8 To edit user label scroll to Edit Label and enter label 9 Repeat the above steps for additional codes Assign Proximity Tag 1 Follow steps 1 5 of the Edit User Code above 2 Se...

Страница 11: ...e POON PO number Partition Part Set code P partition number Partition Unset code US partition number Deactivate Output code POOFF PO number Get system status code ST Omit Zone code OM zone number Chan...

Страница 12: ...present at the premises Let the line ring once hang up and call again If an answering machine is not in use at the premises Wait until the system picks up You will hear a continuous tone 2 After the t...

Отзывы: