Risco lightsys 2 Скачать руководство пользователя страница 4

  

LightSYS2 Quick User Guide

 

LCD Keypad (432KP)

 

Full Set  

Code > 

 

 

Part Set  

Code >

 

 

System Unset and  
Silence an Alarm 

Code>  

Partition Full Set 

Code > 

 

>

 

Partition No. > 

 

 

Partition Part Set 

Code > 

 

>

 

Partition No. > 

 

 

Partition Unset 

Code> 

 > Partition No. > 

 

 

Duress Unset 

Duress Code > 

 

Panic Alarm 

Pressing 

 simultaneously for 2 seconds 

Fire Alarm 

Pressing  

 simultaneously for 2 seconds 

Medical Alarm 

Pressing 

simultaneously for 2 seconds 

Quick Zones Omit  

Code >

 

 [Zone No.]

 

Activate Output 

 [Code] 

 [Activities]

 

 [Prgrm Output Num] 

Define Follow-Me  

>[Code] 

 [Follow Me] 

 [Define]  

View Fault 

 [Code] 

 [View] 

 [Fault]

 

 

View Event Log 

 [Code] 

 [Event Log] 

 

Keypad Chime On/Off 

 [Code] 

 [Activities]

 

 [Keypad sound] 

 [Chime] 

Edit User Code 

 [Code] 

 [Codes/Tags] 

 [Define]

 

Zone Testing (Walk Test)

 [Code] 

 [Maintenance]

 

 [Walk Test]

 

 

 

 

Содержание lightsys 2

Страница 1: ...it appears on the panel or supplied by the installer also available in the keypad menu as described below 6 Complete registration form and click Register 7 To complete registration open the email mes...

Страница 2: ...t Duress Code Panic Alarm Pressing simultaneously for 2 seconds Fire Alarm Pressing simultaneously for 2 seconds Medical Alarm Pressing simultaneously for 2 seconds Quick Zones Omit Code Zone No Activ...

Страница 3: ...lence an Alarm Code Partition Full Set Code Partition No Partition Part Set Code Partition No Partition Unset Code Partition No Duress Unset Duress Code Panic Alarm Pressing simultaneously for 2 secon...

Страница 4: ...Pressing simultaneously for 2 seconds Fire Alarm Pressing simultaneously for 2 seconds Medical Alarm Pressing simultaneously for 2 seconds Quick Zones Omit Code Zone No Activate Output Code Activitie...

Страница 5: ...Code Partition Unset Select partition 1 2 3 4 and press followed by Code Panic alarm Press simultaneously for 2 seconds Fire alarm Press simultaneously for 2 seconds Emergency Med alarm Press simultan...

Страница 6: ...econds Code Panic Alarm simultaneously for 2 seconds Clear Operation Notes For Part setting with no entry delay press and hold for two seconds 1 Consult your engineer for the operations defined with a...

Страница 7: ...on System Unset Code Partition Unset Detector Omit On Off toggle Web Application SET UNSET Full Set All Partitions or PARTITION x Full Set Full Set Group if suppored Group Letter Full Set Or PARTITION...

Страница 8: ...ME ZONE HISTORY Review activity log and export AUTOMATION Programmable Outputs Toggle ON OFF Update Indicators LCD and Touchscreen Keypads Power On Power OK No faults Off No power Rapid Flash System f...

Страница 9: ...y Set Omit On System is Part Set mode or Zone Omit mode Off No omitted zones Tamper On Tamper alarm Off No tamper alarm Cloud connectivity On System connected to cloud Off No cloud connection configur...

Страница 10: ...he new code followed by 8 To edit user label scroll to Edit Label and enter label 9 Repeat the above steps for additional codes Assign Proximity Tag 1 Follow steps 1 5 of the Edit User Code above 2 Se...

Страница 11: ...e POON PO number Partition Part Set code P partition number Partition Unset code US partition number Deactivate Output code POOFF PO number Get system status code ST Omit Zone code OM zone number Chan...

Страница 12: ...present at the premises Let the line ring once hang up and call again If an answering machine is not in use at the premises Wait until the system picks up You will hear a continuous tone 2 After the t...

Отзывы: