VIS300 User Guide

The VIS300 Fiber Inspection Scope is a low cost, and compact Inspection scope for manually verrifying compliance with 

the IEC 61300-3-35 Specification. This document will serve as an overview of the major features and functions of the 

device as well as instructions for use with the Windows InSpec software if you have the USB Variant. If you are looking for 

an standalone automatic inspection system take a look at the VIS300C inspection system. Or if you are looking for a low 

cost Automated inspection scope check out the VIS400.

Introduction

Screen

Live display of the fiber at 

the end of the probe

Connector Adapter

The VIS300 comes with a 

universal 2.5 adapter by 

default, however additional 

adapters are available and are 

user replaceable.

Device Overview

Focus Ring

Spinning this ring clockwise 

focuses toward the fiber while 

counter clockwise moves 

towards the users hand.

Din Connector

This  cable connects the 

probe to the monitor

Power Button

Pressing the Power Button 

will turn on or off the unit

Brightness Controls

These buttons 

alow you to dim 

or brighten the 

monitors image

Mini USB

If you have thet USb Variant 

this lets you connect to the 

desktop inspec software

Содержание MILLER VIS300

Страница 1: ...Page 1 VIS300 User Guide VIS300 Fiber Inspection Scope User Guide...

Страница 2: ...IS300 User Guide Contents Introduction 3 Device Overview 3 Basic Device Functionality 4 Endface Cleaning and Inspection Procedure 5 Integration with Windows InSpec 7 Certifications and Contact Informa...

Страница 3: ...cost Automated inspection scope check out the VIS400 Introduction Screen Live display of the fiber at the end of the probe Connector Adapter The VIS300 comes with a universal 2 5 adapter by default h...

Страница 4: ...pected as well as the accessibility of the fiber end Basic Device Functionality 1 when inspecting an exposed ceramic ferrule you can use your index or thumb to adjust the focus wheel on the VIS300 Cha...

Страница 5: ...perficial and more stuborn debris that may be found on fiber endfaces Dry Cleaning Dry cleaning connector endfaces is accomplished using a one click or cletop cleaner the one click cleaner is used by...

Страница 6: ...the fiber endface with an inspection scope and performing the necessary cleaning actions If a connector endface is particularly dirty three dry cleanings must be performed followed by two wet dry clea...

Страница 7: ...ers will be installed when the software is installed Analyzing and saving a fiber with the InSpec Software Once you connect the VIS300 the Scope tab will appear and you will see the screen below with...

Страница 8: ...e Save button will open the popup below First you need to enter a name for the fiber next you need to assign a location for the fiber if you want to save to the next available index just leave Auto As...

Страница 9: ...dark and light boxes are editable The default settings are shown above Click Reset to Defaults to return to this arrangement of information Enter all info as needed and click Save to have the informat...

Страница 10: ...nerate Inspection Report Generating a Closeout Report First ensure you are on the Reports tab here on the left side you will see any Endface images you have saved along with their comments on the righ...

Страница 11: ...C APC Adapter AC107B LC 60 Adapter AC046B ST Adapter AC047B MTP APC Adapter AC050B MTP Adapter AC048B 1 25 MM universal adapter AC049B 2 5 mm Universal Adapter AC100B ODC Pin Adapter AC101B ODC Socket...

Страница 12: ...erence to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television rece...

Отзывы: