background image

Page 3

DLS355 User Guide

The DLS355 dual Laser source is a low cost compact multimode test Laser used for verifying the proper function of fiber 

optic networks. This document will serve as an overview of the major features and functions of the device and will offer 

tips for troubleshooting common issues in optical networks.

Introduction

Wavelength Indicator

This unit offers 1310nm and 1550nm wavelengths. When the DLS355 is turned on, the red 

light indicates which wavelength is selected. The red light will blink to indicate when the 

2khz modulation is turned ON.

Power Button

Press this button to turn the DLS355 ON and OFF. The unit will turn off automatically after 

15 minutes by default. To disable this timeout hold the power button for at least 5 seconds 

when turning ON.

2kHz Button

Toggles 2kHz tone  on the currently-selected wavelength. This is usefull for detecting which 

fiber is being tested at the other end however the modulation reduces output power by 

Wavelength Button

cycles through either 1310nm or 1550nm wavelengths

Low Battery Indicator

This indicator light will light up when the CR2 battery needs to be replaced.

Do Not Stare Into Beam

Laser Radiation

DO NOT STARE INTO BEAM

CFR 1040.10 IEC 60825-

1:2014-05

Class 1 Laser Product

Connector Adapter

The DLS355 comes with an SC screw-on adapter by default, however additional adapters 

are available and are user replaceable.

Device Overview

Содержание Miller DLS355

Страница 1: ...Page 1 DLS355 User Guide DLS355 Dual Laser Source User Guide...

Страница 2: ...Page 2 DLS355 User Guide Contents Introduction 3 Device Overview 3 Important Safety Information 4 Basic Testing 5 Using 2kHz 6 Maintenance 6 Certifications and Contact Information 7...

Страница 3: ...the DLS355 ON and OFF The unit will turn off automatically after 15 minutes by default To disable this timeout hold the power button for at least 5 seconds when turning ON 2kHz Button Toggles 2kHz ton...

Страница 4: ...d non reflective surfaces to prevent reflection of laser Electric Shock Hazard Pay attention to proper battery polarity Do not mix battery types or manufacturers Do not open the unit with the exceptio...

Страница 5: ...pport see the final page of this document for contact information Transmitting Light The DLS355 transmits either the 1310nm or 1550nm wavelength on Multimode fiber Be sure to use a test jumper to mate...

Страница 6: ...s Be aware that any test jumpers must be inspected and cleaned before plugging into the DLS355 unit If soiled or damaged connectors are inserted they can cause damage to the DLS355 output port and the...

Страница 7: ...ee recalibration within 2 years of the date of purchase To start the calibration process simply call or email technical support Calibration Certificates The DLS355 comes with a 2 year warranty for any...

Страница 8: ...are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and...

Отзывы: