![RIPEnergy HIPHOP pro Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/ripenergy/hiphop-pro/hiphop-pro_user-manual_1463886030.webp)
30/85
V
1.0
47 Planning and mounting the inverter
This section will provide you information’s about configuring and installing your inverter. Make sure that you are
aware of local rules and safety measurements.
47.1
Required power draw
Before connecting your appliances to the inverter, always check the power draw required. The inverter is
affordable to supply surge power for a short time, so as to start up electrical equipment such as pumps, motors,
etc. Some equipment needs more power while starting up.
The inverter is protected against overload and will switch off automatically when overload is applied. As ambient
temperature is above 20°C the inverters nominal power may be smaller due to reduced cooling.
Using the inverter in high altitudes may also reduce nominal power of the inverter because of less heat discharge.
As a rule of thumb, the reduction of nominal power is approximately 1.5% per 100m elevation.
47.2 Installation
These units must be only installed by qualified, authorized and trained personnel familiar with the locally
applicable standards and taking into consideration all relevant safety guidelines and measures!
Before installing the unit check for correct DC-Voltage and power level of the inverter.
The Inverter may be installed in any position. Install the inverter in a dry, well ventilated and dust free location. It
must be installed out of reach for unauthorized personnel especially children’s. Do not install the inverter in the
same compartment as the batteries.
Never use or install the inverter in locations where there is gas or explosive danger!
For proper cooling of the Inverter ensure that the airflow is not obstructed and keep a clearance distance of 2.5cm
to other units. If the inverter is installed in a closed compartment the nominal power may be reduced.
In order to keep the battery cables as short as possible (max. 3m) locate the inverter close to the DC-Distribution
or Battery. Be aware that during charging of batteries an explosive gas can be generated.
Содержание HIPHOP pro
Страница 13: ...13 85 V 1 0 20 Technische Daten 200VA 350VA...
Страница 18: ...18 85 V 1 0 26 Technische Daten JAZZ pro 700 JAZZ pro 1000...
Страница 24: ...24 85 V 1 0 32 Technische Daten HIPHOP pro 1500 HIPHOP pro 2000...
Страница 25: ...25 85 V 1 0 HIPHOP pro 3000...
Страница 33: ...33 85 V 1 0 52 Technical data 200VA 350VA...
Страница 38: ...38 85 V 1 0 58 Technical data JAZZ pro 700 JAZZ pro 1000...
Страница 44: ...44 85 V 1 0 64 Technical data HIPHOP pro 1500 HIPHOP pro 2000...
Страница 45: ...45 85 V 1 0 HIPHOP pro 3000...
Страница 53: ...53 85 V 1 0 84 Caract ristiques techniques 200VA 350VA...
Страница 58: ...58 85 V 1 0 90 Caract ristiques techniques JAZZ pro 700 JAZZ pro 1000...
Страница 64: ...64 85 V 1 0 95 Caract ristiques techniques HIPHOP pro 1500 HIPHOP pro 2000...
Страница 65: ...65 85 V 1 0 HIPHOP pro 3000...
Страница 73: ...73 85 V 1 0 115 Datos t cnicos 200VA 350VA...
Страница 78: ...78 85 V 1 0 121 Datos t cnicos JAZZ pro 700 JAZZ pro 1000...
Страница 84: ...84 85 V 1 0 127 Datos t cnicos HIPHOP pro 1500 HIPHOP pro 2000...
Страница 85: ...85 85 V 1 0 HIPHOP pro 3000...