background image

A Ramp-Hold Practice Program

To  practice  using  the  controller,  we  will  enter  a  pro-

gram that includes three segments. The last segment is 

a cooling segment.

Using the programming instructions on the next col-

umn, enter this firing schedule. The use Program Review 

(page 3) to check for accuracy.

PrO1

rA1 = 250

°

F 1 = 750

HLd 1 = 00.00

rA2 = 900

°

F 2 = 1425

HLd 2 = 00.30

rA3 = 150

°

F 3 = 750

HLd 3 = 00.00

RA4 = 0000 (zeroes cancel segments 4-8)

Skipping a Segment in a Ramp-Hold Program

You can skip a segment in a Ramp-Hold program as 

follows:

1.  The kiln is firing. Press the 

Up Arrow

 key.

2.   

SStP

 will appear. Press the 

Up Arrow

 key again. 

The firing will skip to the next segment.

Skip Segment Example

 

Skipping  to  a  Cooling  Segment: 

You  have  pro-

grammed  a  target  temperature  of  1425°F  for  glass 

fusing, followed by a segment for controlled cooling. 

Watching the glass through the peephole, you notice 

that  the  glass  edges  have  rounded  nicely  at  1375°F. 

Use  Skip  Segment  to  end  the  firing  segment  and 

being one for slow cooling.

Note: 

Make a note of the temperature at which the 

glass  fused.  Program  that  temperature  for  the  next 

firing of that type of glass.

Ramp-Hold Programming Instructions

Note: 

You  have  up  to  8  segments  available  in 

Ramp-Hold.  If  you  don’t  need  all  8,  zero  out  the 

unused segments. See step 6 below.

1.  From 

IdLE

 press 

START

.

2.  Press the 

Up Arrow

 key (not the 

Down Arrow

). 

PrO1 

 

PrO2

 

PrO3

  and 

PrO4

  are  Ramp-Hold 

programs.  When  the  one  you  want  appears, 

press 

START

.  (Ignore 

SPd1

 - 

SPd5

.)

3.  rA  1 

 will appear. Enter fi ring rate (tempera-

ture  change  per  hour)  for  segment  1.  (1°  = 

slowest rate. 1799°F/999°C = full power.) Then 

press 

START

.

4.  °F  1 

 or 

°C  1

  and the target temperature from 

the last firing will appear. Use the arrow keys 

to change the temperature. Then press 

START

5.  HLd 1

 and the hold time from the last firing 

will appear (e.g. 1 hour, 10 minutes = 01.10). 

Use the arrow keys to change the hold time. 

Then press 

START

6.  Continue  entering  values  for  the  segments 

needed. When 

rA_ 

 appears for the next seg-

ment  that  you  don’t  need,  select 

0000

.  The 

press 

ENTER

. This will zero out the remaining 

segments.  (Example:  You  need  only  1  seg-

ment. When 

rA 2

 appears, enter 

0000

.

7.  Strt

 will appear. Press 

START

 to begin firing. 

-On-

  will  appear,  the  Run  indicator  light  will 

begin blinking, and the kiln will begin firing.

To  stop  a  firing  before  completion,  press 

START/

STOP

StOP

  will  appear,  alternating  with  total  firing 

time and kiln temperature.

Note: 

Do  not  be  concerned  if  your  kiln  makes  a 

clicking  sound  during  firing.  Kilns  use  relays  to 

power the elements. The relays click each time their 

electrical contacts come together.

Note:

 The kiln’s actual firing rate may be less than 

the  rate  you  programmed,  depending  on  the  kiln 

model,  available  voltage,  and  density  of  the  load 

you are firing.

When the kiln fires to completion, it will beep for 30 

seconds. The display will show the following:

 Firing time

 Present temperature

 

CPLt

 = Fired to completion

To return to 

IdLE

 , press 

START

.

800.545.6566 

www.riogrande.com

Sentry Express Digital Temperature Controller

Sharing your passion for making jewelry.

Products. Service. Know-how.

Содержание Sentry Express

Страница 1: ...ram From IdLE or during firing press Down Arrow The program you have selected will appear one step at a time 3 Delays a Firing From Strt press Down Arrow F C C Display Dot Time Display Center Display...

Страница 2: ...ailure 9 PF 2 Power Failure 9 tC Thermocouple Failure 9 Selecting F or C Display 9 Display Messages 10 Trouble Shooter 10 Problem Controller display is blank No heat in kiln 10 Problem Controller disp...

Страница 3: ...because the numbers scroll below 0000 to the highest number and vice versa Examples To program a 99 59 hour Hold when the display shows 00 00 press the Down Arrow once To program a FULL rate when the...

Страница 4: ...o miles per hour In summary the controller does three basic tasks 1 It fires at a controlled heating rate or speed mea sured in degrees of temperature change per hour 2 It fires to a target temperatur...

Страница 5: ...F 555 C rate per hour List continues on next page Single Segment Programming Instructions Note Single Segment firing is all you will ever need if you are only going to a temperature and holding 1 Fro...

Страница 6: ...dy to fire a different program select PrO2 which is Program 2 Then enter temperatures heating rates etc Select Program 3 and 4 the same way A program can have up to 8 segments but you don t have to us...

Страница 7: ...ss START Ignore SPd1 SPd5 3 rA 1 will appear Enter firing rate tempera ture change per hour for segment 1 1 slowest rate 1799 F 999 C full power Then press START 4 F 1 or C 1 and the target temperatur...

Страница 8: ...Segment 3 lowers the temperatures to 800 F 426 C the typical casting temperature for silver Most types of gold cast at 900 F 482C Note Casting temperature depends on the size of the mold The temperatu...

Страница 9: ...FtL Firing Too Long This message appears when both of the following conditions are met The temperature rise or fall is less than 27 F 15 C per hour The firing is 4 hours longer than programmed See Con...

Страница 10: ...s when you press the Up Arrow key during a Ramp Hold firing If you press the Up Arrow again the fir ing will skip out of a segment into the next segment STOP The firing was stopped by pressing START S...

Страница 11: ...Power Output Test Is the controller sending voltage to the relay Test OUTPUT with a voltmeter 1 UNPLUG kiln disconnect the power Remove the 4 screws holding the controller faceplate to the switch box...

Страница 12: ...sing the keys in left column the center message will appear Single Segment Keys to Press Display IdLE SPd1 thru PrO4 Not Down Arrow Select rate SPd1 Sample rate F or C Enter temperature 1900 Sample te...

Отзывы: