48
Rinnai Rack Installation
5. Install the flex line assembly from step 3 onto the RUR98 unit.
6. Remove the cold flex line from the second RUC98 unit.
For TRW02ST racks
,
the conversion is now complete.
For TRW03ST racks
, a PVA valve and threaded nipple (supplied in Kit 104000278)
must be added to the cold flex line assembly on the second RUC98. See the next step
for detailed instructions.
IMPORTANT:
When conversion steps are complete, the water heater recirculation settings must be
adjusted. Refer to the ―Cross Over Mode‖ section in the ―Rinnai Direct Vent Tankless Water Heater
with Integrated Pump Installation and Operation Manual‖ (shipped with KBP water heater models) for
detailed instructions (
Installation Instructions
►
Recirculation Modes
►
Cross Over Mode
).
RUR98
RUC98
RUC98
RUR98
RUC98
RUC98
Flex line assembly
PVA
Valve
Threaded
Nipple
Cold Flex Line