![Rinnai TRC02i Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/rinnai/trc02i/trc02i_installation-manual_1463156031.webp)
31
Rinnai Rack Installation
Clearances
Install the rack system so that the clearances shown below are followed.
to
Combustibles
inches (mm)
to Non-
Combustibles
inches (mm)
Top of Heater
6 * (152)
2 *(51)
Back of Heater
0 (zero)
0 (zero)
Front of Heater
6 (152)
6 (152)
Sides of Heater
2 (51)
1/2 (13)
Ground/Bottom
12 (305)
12 (305)
Vent
0 (zero)
0 (zero)
* 0 inches from vent components and condensate
drain line.
The clearance for servicing is 24 inches in front of the
water heater.
For closet installation, clearance is 6 inches (152 mm
from the front.
Indoor models: RUC98i, C199i, RUR98i
to
Combustibles
inches (mm)
to Non-
Combustibles
inches (mm)
Top of Heater
12 (305)
2 (51)
Back of Heater
0 (zero)
0 (zero)
Front (panel)
24 (610)
0 (zero)
Front (exhaust)
24 (610)
24 (610)
Sides of Heater
6 (152)
1/8 (3.2)
Ground/Bottom
12 (305)
2 (51)
Outdoor models: RU98e, C199e, RUR98e
The clearance for servicing is 24 inches in front of the
water heater.
Top
of Heater
Side
of Heater
Front
of Heater
Ground/Bottom
Top
of Heater
Side
of Heater
Front
of Heater
Ground/Bottom
Содержание TRC02i