Owner’s Manual

25L and 50L Electric Storage Water Heaters

7

RIN3699    023334    Rev. A

Safety

This appliance is not intended for use 
by persons (including children) with 
reduced physical, sensory or mental 
capabilities, or lack of experience and 
knowledge, unless they have been given 
supervision or instruction concerning 
use of the appliance by a person 
responsible for their safety.
Children and animals should be 
supervised to ensure that they do not 
interfere with the appliance.

Filling The Water Heater

Open all hot water taps. Open isolating 
valve at the cold water inlet slowly and 
allow water heater to fill until water flows 
through the system. Close each hot 
water tap after the air is expelled from 
its line. As noted previously power is not 
to be turned on until the water heater is 
filled with water.

Water Quality

Your Rinnai water heater has been 
manufactured to suit water conditions of 
most Australian metropolitan supplies. 
Please note that harsh water supplies 
can have a detrimental effect on the 
water heater and its life expectancy. If 
you are unsure about your water quality 
you can obtain information from your 
local water supply authority.
The water heater is designed for use 
in areas where the Total Dissolved 
Solids (TDS) content of the water 
supply is less than 2500 mg/L. In areas 

where the TDS exceeds 600mg/L it 
is possible that the magnesium alloy 
anode (supplied in the heater) may 
become over reactive. To alleviate this, 
the magnesium alloy anode should be 
replaced with an aluminium alloy anode, 
available from your local Rinnai supplier.
Water can also be very corrosive, the 
measure of this is the saturation index. 
If the water saturation index is greater 
than 0.40, an expansion control valve 
should be fitted. If the index is greater 
than 0.80, the water heater installed 
should be a Hard Water Model. Please 
consult our Service Department for 
advice if required.

Caution

If the water heater is left in an operating 
condition and unused for two weeks or 
more, a quantity of hydrogen (which is 
highly flammable) may accumulate in the 
top of the water cylinder. To dissipate 
this gas safely it is recommended that 
a hot tap be turned on for several 
minutes at a sink, basin or bath, but not 
a dishwasher, clothes washer or other 
appliance. During this procedure there 
must be no smoking, open flame or 
any other electrical appliance operating 
nearby. If hydrogen is discharged 
through the tap it will probably make an 
unusual sound as with air escaping.

Where the water heater is not 
installed in accordance with the listed 
advice, the water heater will not be 
covered by the Terms of Warranty. 

Operating Instructions

Содержание RIN25E24P

Страница 1: ...als may change without notice Effective for all 25L and 50L electric storage water heaters manufactured and sold after 1st May 2011 Carefully remove all packaging and transit protection from the heater before installation Dispose of the packaging responsibly using re cycling facilities where they exist Installation Details Owner s Information ...

Страница 2: ...ctric Storage Water Heaters RIN3699 023334 Rev A Installation Details 1 Plumbing Connections 3 Electrical Connection 5 Specifications 6 Operating Instructions 7 Safety Information 8 Service Information 9 Troubleshooting 10 Contents ...

Страница 3: ...l the relevant Standards Only a licensed person will have insurance protecting their workmanship for 6 years Make sure you use a licensed person to install this water heater and ask for your Compliance Certificate Water Supply Pressure This water heater is designed for direct connection to water supply pressures of 25 50 Litre Models 800kPa Where the mains pressure can exceed or fluctuate beyond t...

Страница 4: ...pped with a sacrificial anode accessible through the top cover Allow 50 of the height of the water heater for clearance above to replace the anode We recommend a plinth be installed under the water heater where the water heater is subjected to wet conditions A properly drained overflow tray must be used where property damage could occur from water spillage See AS NZS3500 4 2 for further details Wh...

Страница 5: ...d be checked for adequate performance or replaced at intervals not exceeding 5 years or less in areas where local regulations apply Important The PTR Valve and its drain outlet pipe must not be sealed or blocked It is normal for the PTR valve to leak a small amount of water during heating cycles Danger Failure to operate the relief valve easing lever at least once every six 6 months may result in ...

Страница 6: ...olating valve non return valve line strainer may be used Expansion valve only required where local regulations demand Union Connection Non return Valve Line Strainer Cold Water Inlet Drain Expansion Valve Isolating Valve Spindle Vertical Inlet Connections Temperature Protection Water heaters can produce very hot water To reduce the risk of scald injury it is mandatory under the requirements of Aus...

Страница 7: ...m conduit The element cover may be removed by undoing the two screws on the cover and sliding the cover downwards to disengage the top edge Ensure that the conduit entry is well sealed to achieve correct weatherproofing Note This water heater is fitted with a thermostat and over temperature energy cut out Under no circumstances should the water heater be operated without both these devices being i...

Страница 8: ...y L 31 53 Hot Water Delivery L 25 50 Net Weight Empty kg 17 22 Element Sizes kW 2 4 2 4 3 6 Relief Valve Pressure kPa 1000 Temperature C 99 Power Rating kW 10 Country of Origin China Nominal Dimensions 25L 50L Total Height A 452 694 Total Width B 405 405 Outlet Height C 297 524 Inlet Height D 153 158 Electrical Entry E 67 67 A C D E B ...

Страница 9: ...otal Dissolved Solids TDS content of the water supply is less than 2500 mg L In areas where the TDS exceeds 600mg L it is possible that the magnesium alloy anode supplied in the heater may become over reactive To alleviate this the magnesium alloy anode should be replaced with an aluminium alloy anode available from your local Rinnai supplier Water can also be very corrosive the measure of this is...

Страница 10: ...lectrical cover is removed Open the PTR Valve for approximately 10 seconds by lifting the lever on the valve to ensure water is relieved to waste through the relief drain pipe Lower lever gently and check that it closes correctly The PTR Valve must not be tampered with or removed The water heater must not be operated unless this valve is fitted and in working order The PTR Valve should be checked ...

Страница 11: ...ater conditions it is recommended that you carry out a more frequent check of your anode s condition refer Operating Instructions Water Quality Flush the water heater by doing the following i Turn off the power ii Turn off the cold water supply to the water heater at the isolating valve iii Gently operate the easing lever on the Pressure Temperature Relief Valve to release the pressure in the wate...

Страница 12: ...f time If it is not possible to adjust water usage patterns an inexpensive flow control valve can easily be fitted to the shower outlet Consider that during night time heating the time taken to heat the tank can take longer so you may find that the tank has not fully recovered from a period of heavy usage the previous evening Consider that often the hot water usage of showers washing machines and ...

Страница 13: ... for a few seconds then release gently This may dislodge a small particle of foreign matter and rectify the fault Steady flow PTR more than 20L per day This may be caused by excessive water supply pressure a faulty Pressure Temperature Relief Valve or a faulty thermostat Turn off the electricity supply and contact Rinnai High Electricity Bills Is the Pressure Temperature Relief Valve discharging t...

Страница 14: ...Under this warranty Rinnai will repair or replace the component or hot water unit free of charge except for certain transport or travelling time costs which may be payable by the owner under clause 9 below The decision to repair or replace the component or hot water unit will be entirely at the discretion of Rinnai 3 The warranty only applies to defects in the hot water unit which have arisen sole...

Страница 15: ... a hot water unit or a component in a hot water unit is replaced by Rinnai the balance of any original warranty or replacement guarantee period will remain effective The replacement part or hot water unit does not carry any additional warranty or replacement guarantee 8 Where the hot water is located outside the metropolitan area of a capital city and is a more than 25 kilometres from a Rinnai off...

Страница 16: ... warranty and replacement guarantee certain legislation including the Trade Practices Act 1974 and consumer protection legislation of the States and Territories gives the owner certain rights which cannot be excluded restricted or modified Nothing in this warranty and replacement guarantee has the effect of excluding restricting or modifying those rights 13 In the case of a hot water unit acquired...

Страница 17: ...Owner s Manual 25L and 50L Electric Storage Water Heaters 15 RIN3699 023334 Rev A ...

Страница 18: ...55 545 Fax 1300 555 655 Cost of a local call higher from mobile or public phones Hot Water Service Line Tel 1800 000 340 Australia Pty Ltd ABN 74 005 138 769 Internet www rinnai com au E mail enquiry rinnai com au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance If your appliance requires service please...

Отзывы: