Step 6.

Connect Transition Box to Engine

Align the guide rails 

 with the guide plate 

 of the transition

box assembly and slide the assembly, in until the guide plate

 is fully home against the rear of the flange at the top of the

heater engines main body 

.

Step 7.

Positioning the Heater Engine

Place the heater engine in front of the zero clearance box /
cavity. 

Step 8.

Connect Electrical Supply

Plug in 3 pin connector if electrical connections are inside the
fireplace.

Step 9.

Insert Heater Engine Into Fireplace

Carefully move the heater engine into the zero clearance box
ensuring the gas supply pipe and fittings 

 

feed into the rear

access hole.

Step 10. Connect Flue

 

Connect flue in accordance with the ‘Flueing Installation
Manual For Rinnai Flamefire Heaters’ supplied with flue kit.

Step 11. Secure Flue

Replace the flue access plate 

 

and secure the guide plate

 of the transition box assembly to the flue access plate 

with 

two screws 

 (supplied). Re-secure the flue access plate

 to the heater engine three screws.

Step 12. Connecting Gas

Connect gas supply pipe and fittings 

 

to the gas control

valve inlet 

 

and tighten.

Step 13. Securing The Heater Engine

Fasten the heater engine to cladding surface using
appropriate fasteners (not supplied) using the three holes
across the top of the fascia assembly mounting panel and
three holes on each side of the side panels as shown 

.

Step 14. Leak Testing

Turn gas back ON and leak test all appliance connections.

Step 15. Completing Heater Installation

Go to “COMPLETING HEATER INSTALLATION” on page 23. 

A panel from the cardboard packing carton
placed on the floor underneath the heater engine
will help prevent possible damage to flooring.

Take care that the electrical cord does not bunch
up or get pinched behind the heater engine.

Use a soapy solution to test all gas connections.
If a leak is present bubbles will form at the leak
point. When finished remove any residue with a
rag. Prevent any soapy solution from coming in
contact with electrical components.

Q

S

N

Q

T

T

Q

U

M

C

R

C

Refer to flue

installation

instructions

A

M

C

C

R

HINT

Q

CAUTION

N

C

N

S

N

Q

T

U

CAUTION

Содержание RIBF2L

Страница 1: ...This appliance shall be installed in accordance with All Rinnai gas products are A G A certified SLIMFIRE 252 0 0 1 123 4 05 05...

Страница 2: ...limfire 252 gas log flamefire We trust you will have many years of comfort and enjoyment from your appliance BEFORE PROCEEDING WITH THE OPERATION OR INSTALLATION OF YOUR NEW HEATER PLEASE READ THIS MA...

Страница 3: ...ETY DEVICES 5 ABOUT YOUR HEATER 6 GENERAL DESCRIPTION 6 DESIGN FEATURES 6 OPERATION 7 TO TURN YOUR HEATER ON 7 ADJUSTING HEAT 7 FAN OPERATION 7 TO TURN YOUR HEATER OFF 7 POWER OUTAGES 7 CARE AND MAINT...

Страница 4: ...eeding with the installation The Engine and Fascia are packed into two separate cartons and are required for all installation types Masonry installations may require a flexiliner flue to be installed...

Страница 5: ...Compliance Certification Number _____________________________________________ Authorised Persons Licence Number _____________________________________________________ Installers Signature ____________...

Страница 6: ...y persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appli...

Страница 7: ...place articles on this heater DO NOT place articles in front of the louvres DO NOT operate install this heater in areas where painting is taking place or in places such as hairdressing salons where t...

Страница 8: ...imber This affect may be amplified if the air in the room contains cooking vapours or cigarette smoke To avoid this possibility it is recommended that a mat be placed in front of the appliance extendi...

Страница 9: ...installed in a zero clearance box through a 100mm x 150mm twin skinned flue to the outside of the house 1 Fireplace Masonry installation Engine The appliance is directly mounted into an existing maso...

Страница 10: ...ols are located on the front lower left hand side of the heater Step 1 Press the right hand control Ignition Low button firmly This operates the built in safety device and starts the electronic spark...

Страница 11: ...ols in the vicinity of the heater whilst in operation DO NOT place articles on or against this heater DO NOT store flammable materials near this heater DO NOT remove any panels or attempt to carry out...

Страница 12: ...alled There are some warning signs that could indicate a problem If any of the signs below occur please contact Rinnai Key signs of abnormal flame performance Appliance turns OFF soon after start up a...

Страница 13: ...HEATER ENGINE INSTALLATION MASONRY 18 MASONRY INSTALLATION OVERVIEW 18 MASONRY INSTALLATION DETAIL 18 HEATER ENGINE INSTALLATION ZERO CLEARANCE 20 ZERO CLEARANCE INSTALLATION OVERVIEW 20 ZERO CLEARAN...

Страница 14: ...m Rectangular spigot rear discharge 43mm x 245mm Convection Fan Tangential 2 speed power rating 28 Watts Gas connection 1 2 BSPF male flare Gas Control Push button combination control valve Operation...

Страница 15: ...Rinnai Australia 12 Slimfire 252 Operation Installation Manual DIMENSIONS A B C D E F G H I J K 750mm 645mm 582mm 528mm 275mm 310mm 25mm 45mm 280mm 79mm 43mm A B D E I F H J K G C...

Страница 16: ...their manufacturers instructions It is the responsibility of the installer end user to check the installation instructions of these items and to ensure the location is suitable This caution also exte...

Страница 17: ...s are shown below The enclosure dimensions specified are critical to the successful installation of this appliance and must be strictly adhered to AS NZS 5601 GAS INSTALLATIONS requires that flue comp...

Страница 18: ...Barrel Union Elbow are provided for connection to the consumer piping They are shipped inside the engine attached to on the gas inlet connection of the heater Refer to the table below and the dimensi...

Страница 19: ...y an authorised person must install service and remove the Rinnai Slimfire 252 space heater and flue system Only the flue system components described in the Flueing Installation Manual For Rinnai Flam...

Страница 20: ...eet these criteria will not only void the product warranty but may affect the performance of the heater Chimney Criteria For Open Installation All loose broken bricks must be replaced or repaired ensu...

Страница 21: ...e top edge The foam strip is intended to form a seal between the heater and the fireplace brickwork If an adequate seal cannot be formed then another means of sealing must then be used e g non combust...

Страница 22: ...ions Step 9 Securing The Heater Engine Fasten the heater to the masonry work using appropriate fasteners not supplied using the three holes across the top of the fascia assembly mounting panel and in...

Страница 23: ...anual thoroughly and gain a full understanding of the requirements before undertaking installation Ensure gas supply to heater is turned off for the first stages of this instruction Step 1 Prepare Sit...

Страница 24: ...e is evident DO NOT install or operate this appliance Contact your supplier for advice Before installing the heater check it is labelled for the correct gas type refer to the gas type label on the top...

Страница 25: ...ue access plate with two screws supplied Re secure the flue access plate to the heater engine three screws Step 12 Connecting Gas Connect gas supply pipe and fittings to the gas control valve inlet an...

Страница 26: ...it can not get damaged Step 2 Unpacking the Log Set Granules Satchel Unpack the log set and the burner granules These are attached to the outside top of the heater engine Carefully unpack the logset f...

Страница 27: ...the granular burner medium may now begin for best flame effect carefully place DO NOT POUR the granular burner medium over and around the front burner ports It is desirable that the gas jet is diffuse...

Страница 28: ...as there is potential for electric shock from the exposed wiring and circuitry DO NOT leave the appliance unattended when power is connected and the panels are removed Installation and commissioning m...

Страница 29: ...scia securing tabs The glass dress guard fitted to this appliance reduces the risk of fire and injury and no part of it should be permanently removed For protection of young children or the infirm a s...

Страница 30: ...ning signs that could indicate a problem If any of the signs below occur please contact Rinnai Key signs of abnormal flame performance Appliance turns OFF soon after start up and does not relight Flam...

Страница 31: ...220 240 v 50 Hz BR G Y BL W W BL BL W IGNSWITCH MICRO BR BL FAN SWITCH ON OFF THERMAL 1 2 3 R BL BL R W FAN SWITCH HI LOW MICRO SPARKER ELECTRODE W SV OHS TC WIRING DIAGRAM PN10153 W R RED BL BLUE BR...

Страница 32: ...firm a secondary guard is required Ensure this Operation and Installation manual is left with the customer Ensure the Customer understands that No part of this appliance should be permanently removed...

Страница 33: ...Rinnai Australia 30 Slimfire 252 Operation Installation Manual NOTES...

Страница 34: ...Rinnai Australia 31 Slimfire 252 Operation Installation Manual NOTES...

Страница 35: ...Rinnai Australia 32 Slimfire 252 Operation Installation Manual NOTES...

Страница 36: ...local call Higher from mobile or public phones Australia Pty Ltd ABN 74 005 138 769 Internet www rinnai com au E mail enquiry rinnai com au Rinnai has a Service and Spare Parts network with personnel...

Отзывы: