Rinnai Australia
15
Operation Manual
CARE AND MAINTENANCE
CLEANING
Your heater needs very little maintenance, however the following information will help you keep it looking good and
working efficiently.
FILTERS
•
Unplug electrical cord before cleaning.
•
DO NOT USE SOLVENTS. All parts of the heater and remote control can be cleaned using
a soft, damp cloth and a mild detergent.
•
DO NOT attempt to clean the heater while the appliance is hot or operating.
The filter meshing for this appliance is fixed to the inlets of the room
air return
.
The build up of dust or other particles on these filter strips reduces the
air flow through to the heater which in turn reduces heater's efficiency
and can lead to the appliance shutting down.
Filter Care
Filters require cleaning regularly during the heating season to prevent
these unnecessary cut-outs.
Cleaning filter strips:
Clean any dust and other debris from both faces of the filters with
either a vacuum cleaner, a soft dry cloth or a soft brush.
NEVER
attempt to clean filters with water.
Heater shut down due to filter blockages
DO NOT
wait for the Filter Blockage Indicator to come on before
cleaning filters.
DO NOT
continue to use the heater once this Indicator is flashing.
When an obstructive build up is detected the Blockage Indicator LED
which is located above the Receiver Window
will begin to flash
RED to let you know that there is a problem.
Once the Indicator is flashing if no action is taken the heater will
eventually shut down to avoid overheating and a fault code of 14 will
be displayed in the Error Display
window.
Returning the appliance to normal operation after a shut down
To restore to normal operation after a filter blockage shut down do the
following:
1.
Press the On/Off
button once to turn off the heater.
2.
Remove obstruction (see “Filter Care” on page 15).
3.
Press the On/Off
button once to turn the heater back on.
4.
Use the remote control to resume normal heater operation.
WARM AIR VENT
It is important that the Warm Air Discharge Vent
be kept clear of
any obstructions as this will cause your heater to operate less
efficiently.
When an obstruction is detected the Blockage Indicator LED which is
located next to the Receiver Window
will illuminate RED and the
combustion state reduces to front burner, low operation only.
To restore normal operation remove the obstruction and use the
remote control to resume normal heater operation.
NOTE