Value
Series
Manual
23
Final
Checklist
□
The
water
heater
is
not
subject
to
corrosive
compounds
in
the
air.
□
The
water
supply
does
not
contain
chemicals
or
exceeds
total
hardness
that
will
damage
the
heat
exchanger.
□
Clearances
from
the
water
heater
unit
are
met.
□
Clearances
from
the
vent
termina on
/
air
intake
are
met.
□
For
indoor
models,
ensure
you
have
used
the
correct
ven ng
products
for
the
model
installed
and
that
you
have
completely
followed
the
ven ng
manufacturer’s
installa on
instruc ons
and
these
installa on
instruc ons.
□
For
indoor
models,
verify
that
the
vent
system
does
not
exceed
the
maximum
length
for
the
number
of
elbows
used.
□
For
indoor
models
verify
that
switch
No.
1
in
the
SW1
DIP
switch
(tan
switches)
has
been
adjusted
for
vent
length
if
necessary.
Refer
to
the
sec on
on
Maximum
Vent
Length.
□
For
indoor
models,
verify
that
the
vent
pipe
has
a
downward
slope
or
grade
to
the
outside
of
1/4
inch
per
foot
(1.2
°
)
OR
if
the
vent
pipe
is
sloped
toward
the
water
heater
(as
some
local
codes
require),
that
a
condensate
collector
is
installed
to
allow
condensa on
to
drain
away
from
the
water
heater
to
a
proper
drain
source.
□
For
indoor
models,
verify
that
condensate
will
not
be
allowed
to
drain
back
into
the
water
heater.
□
Purge
the
water
line
of
all
debris
and
air
by
closing
the
hot
isola on
valve
and
opening
the
cold
isola on
valve
and
its
drain.
Debris
will
damage
the
water
heater.
Use
a
bucket
or
hose
if
necessary.
□
Ensure
that
hot
and
cold
water
lines
are
not
crossed
to
the
unit
and
are
leak
free.
□
Clean
the
inlet
water
fi
lter
by
closing
the
cold
and
hot
water
inlet
isola on
(shut
‐
o
ff
)
valves.
Put
a
bucket
under
the
fi
lter
at
the
bo om
of
the
water
heater
to
catch
any
water
that
is
contained
inside
the
unit.
Unscrew
the
water
fi
lter.
Rinse
the
fi
lter
to
remove
any
debris.
Install
the
fi
lter
and
open
the
isola on
valves.
□
Ensure
that
a
pressure
relief
valve
is
installed
with
a
ra ng
that
exceeds
the
BTU
input
of
the
water
heater
model.
Refer
to
the
ra ng
plate
on
the
side
of
the
water
heater
for
BTU
input.
□
A
manual
gas
control
valve
has
been
placed
in
the
gas
line
to
the
water
heater.
□
Check
the
gas
lines
and
connec ons
for
leaks.
□
Con
fi
rm
that
the
gas
inlet
pressure
is
within
limits.
□
Con
fi
rm
that
the
water
heater
is
rated
for
the
gas
type
supplied.
□
Con
fi
rm
that
the
electricity
is
supplied
from
a
120
VAC,
60
Hz
power
source,
is
in
a
properly
grounded
circuit,
and
turned
on.
□
Verify
the
temperature
controller
is
func oning
properly.
□
For
the
V75i/e,
verify
that
switches
No.
2
and
No.
3
in
the
SW1
DIP
switch
(tan
switches)
is
set
correctly
for
your
al tude.
□
Verify
the
system
is
func oning
correctly
by
connec ng
your
manometer
to
the
gas
pressure
test
port
on
the
water
heater.
Operate
all
gas
appliances
in
the
home
or
facility
at
high
fi
re.
The
inlet
gas
pressure
at
the
water
heater
must
not
drop
below
that
listed
on
the
ra ng
plate.
□
If
the
water
heater
is
not
needed
for
immediate
use,
then
drain
the
water
from
the
heat
exchanger.
□
Install
the
front
panel.
□
Explain
to
the
customer
the
importance
of
not
blocking
the
vent
termina on
or
air
intake.
□
Explain
to
the
customer
the
opera on
of
the
water
heater,
safety
guidelines,
maintenance,
and
warranty.
□
The
installa on
must
conform
with
local
codes
or,
in
the
absence
of
local
codes,
with
the
Na onal
Fuel Gas Code, ANSI Z223.1/NFPA 54
,
or
the
Natural Gas and Propane Installa on Code, CSA
B149.1
.
If
installed
in
a
manufactured
home,
the
installa on
must
conform
with
the
Manufactured
Home Construc on and Safety Standard, Title 24
CFR, Part 3280
and/or
CAN/SCA Z240 MH Series,
Mobile Homes
.
□
Leave
the
en re
manual
taped
to
the
water
heater
(indoor
models),
temperature
controller
(outdoor
models),
or
give
the
en re
manual
directly
to
the
consumer.