V53e Outdoor Manual
31
Remote
Controller
Installation
1. Determine a suitable location for the controller.
2. Make three holes in the wall as shown.
3. Run the cable between the controller and the Rinnai water
heater or the controller and another controller.
4. Remove the face plate from the remote controller using a
screwdriver.
5. Connect the cable to the remote controller.
6. Mount the controller to the wall using the holes drilled in
step 2.
Do not attempt to connect the remote controllers with the power on. There is 120 volt
potential, next to the remote controller connections inside the unit.
Do not connect the remote controller to the 120VAC terminals provided for the
optional solenoid drain valves.
All service and wiring should be performed by a registered installer.
WARNING
Outline of Remote
securing screw
1-21/32"
3-5/16"
securing screw
wiring hole
7. Disconnect the power from the water heater.
8. Remove a screw on the Quick Cable Connector.
(Figure 1)
9. To access the cable screws rotate the Quick Cable
Connector 90º counterclockwise. (Figure 2)
10. Insert wire cable through the Cable Access Hole so that it
can be accessed from the back. (Figure 2)
11. Loosen the clamp screw and secure wire cable with clamp.
The clamp is in the box with the remote controller. Make
sure the length of the wire is long enough. There should
be no tension in the wire. (Figure 3)
12. Loosen 2 cable screws on the terminals for controls and
connect the cable. You cannot connect more than 2
cables at a time. When connecting more than 2 cables,
connect them in parallel. (Figure 4)
13. Install the Quick Cable Connection with 1 screw. (Figure 5)
Mounting on the wall
Follow the procedure below to install an MC-91 remote
controller.
Содержание REU-VAM1620W